髌骨植入物临床前评估方法

M. Kersh, H. Ploeg
{"title":"髌骨植入物临床前评估方法","authors":"M. Kersh, H. Ploeg","doi":"10.1504/IJECB.2009.029189","DOIUrl":null,"url":null,"abstract":"A methodology for the alignment of patellar and femoral components in pre-clinical test of patellar components used in total knee arthroplasty is presented. The component alignment was based on kinematic degrees of freedom that should be considered to recreate clinically relevant patello-femoral contact patterns. A literature review of patellar kinematics revealed that patellar motion occurs in all six degrees of freedom. Retrieval studies reported that deformation was most prominent on the lateral aspect of the patellar component and in contact regions that occur at higher degrees of knee flexion. Based on this review, it was hypothesised that alignment of the patellar and femoral components should incorporate patellar flexion, proximal-distal translation, anterior-posterior translation and medial-lateral translation. The efficacy of the model was tested by evaluating its ability to create physiological contact patterns in patellar components used in total knee arthroplasty. Two types of components were tested: metal-backed dome and all-polyethylene sombrero-shaped of which the dome-shaped components have a higher reported incidence of failure. The component alignment method resulted in higher contact areas in the sombrero-shaped components than the dome-shaped. Contact patterns of both components were compared to contact patterns reported in the literature for natural and implanted patellae and compared favourably.","PeriodicalId":90184,"journal":{"name":"International journal of experimental and computational biomechanics","volume":"1 1","pages":"129"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1504/IJECB.2009.029189","citationCount":"0","resultStr":"{\"title\":\"A methodology for the pre-clinical evaluation of patellar implants\",\"authors\":\"M. Kersh, H. Ploeg\",\"doi\":\"10.1504/IJECB.2009.029189\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A methodology for the alignment of patellar and femoral components in pre-clinical test of patellar components used in total knee arthroplasty is presented. The component alignment was based on kinematic degrees of freedom that should be considered to recreate clinically relevant patello-femoral contact patterns. A literature review of patellar kinematics revealed that patellar motion occurs in all six degrees of freedom. Retrieval studies reported that deformation was most prominent on the lateral aspect of the patellar component and in contact regions that occur at higher degrees of knee flexion. Based on this review, it was hypothesised that alignment of the patellar and femoral components should incorporate patellar flexion, proximal-distal translation, anterior-posterior translation and medial-lateral translation. The efficacy of the model was tested by evaluating its ability to create physiological contact patterns in patellar components used in total knee arthroplasty. Two types of components were tested: metal-backed dome and all-polyethylene sombrero-shaped of which the dome-shaped components have a higher reported incidence of failure. The component alignment method resulted in higher contact areas in the sombrero-shaped components than the dome-shaped. Contact patterns of both components were compared to contact patterns reported in the literature for natural and implanted patellae and compared favourably.\",\"PeriodicalId\":90184,\"journal\":{\"name\":\"International journal of experimental and computational biomechanics\",\"volume\":\"1 1\",\"pages\":\"129\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1504/IJECB.2009.029189\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of experimental and computational biomechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJECB.2009.029189\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of experimental and computational biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJECB.2009.029189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种在全膝关节置换术中髌骨组件临床前测试中髌骨和股骨组件对齐的方法。部件对齐基于运动学自由度,应考虑重建临床相关的髌骨-股骨接触模式。髌骨运动学的文献回顾显示,髌骨运动发生在所有六个自由度。检索研究报告,变形是最突出的外侧方面的髌骨组成部分和接触区域,发生在较高程度的膝关节屈曲。基于这篇综述,我们假设髌骨和股骨组成部分的对齐应该包括髌骨屈曲、近端到远端平移、前后平移和中外侧平移。该模型的有效性是通过评估其在全膝关节置换术中髌骨组件中创造生理接触模式的能力来测试的。测试了两种类型的组件:金属圆顶和全聚乙烯宽边帽形状,其中圆顶形状的组件报告的失效发生率更高。元件对准方法使得帽形元件的接触面积比圆顶形元件的接触面积大。将这两种组件的接触模式与文献中报道的天然髌骨和植入髌骨的接触模式进行了比较,并进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A methodology for the pre-clinical evaluation of patellar implants
A methodology for the alignment of patellar and femoral components in pre-clinical test of patellar components used in total knee arthroplasty is presented. The component alignment was based on kinematic degrees of freedom that should be considered to recreate clinically relevant patello-femoral contact patterns. A literature review of patellar kinematics revealed that patellar motion occurs in all six degrees of freedom. Retrieval studies reported that deformation was most prominent on the lateral aspect of the patellar component and in contact regions that occur at higher degrees of knee flexion. Based on this review, it was hypothesised that alignment of the patellar and femoral components should incorporate patellar flexion, proximal-distal translation, anterior-posterior translation and medial-lateral translation. The efficacy of the model was tested by evaluating its ability to create physiological contact patterns in patellar components used in total knee arthroplasty. Two types of components were tested: metal-backed dome and all-polyethylene sombrero-shaped of which the dome-shaped components have a higher reported incidence of failure. The component alignment method resulted in higher contact areas in the sombrero-shaped components than the dome-shaped. Contact patterns of both components were compared to contact patterns reported in the literature for natural and implanted patellae and compared favourably.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信