A. Salazar, Javier Romero, Oscar Bernal, Angela Moreno, Sofía Velasco, Xavier A. Díaz
{"title":"计算机x线摄影、胶片和数字化胶片在远程摄影服务中的临床表现的非劣效性和等效性评价","authors":"A. Salazar, Javier Romero, Oscar Bernal, Angela Moreno, Sofía Velasco, Xavier A. Díaz","doi":"10.1155/2016/3642960","DOIUrl":null,"url":null,"abstract":"Objective. The aim of this study was to evaluate and compare the clinical performance of different alternatives to implement low-cost screening telemammography. We compared computed radiography, film printed images, and digitized films produced with a specialized film digitizer and a digital camera. Material and Methods. The ethics committee of our institution approved this study. We assessed the equivalence of the clinical performance of observers for cancer detection. The factorial design included 70 screening patients, four technological alternatives, and cases interpreted by seven radiologists, for a total of 1,960 observations. The variables evaluated were the positive predictive value (PPV), accuracy, sensitivity, specificity, and the area under the receiver operating characteristic curves (AUC). Result. The mean values for the observed variables were as follows: accuracy ranged from 0.77 to 0.82, the PPV ranged from 0.67 to 0.68, sensitivity ranged from 0.64 to 0.74, specificity ranged from 0.87 to 0.90, and the AUC ranged from 0.87 to 0.90. At a difference of 0.1 to claim equivalence, all alternatives were equivalent for all variables. Conclusion. Our findings suggest that telemammography screening programs may be provided to underserved populations at a low cost, using a film digitizer or a digital camera.","PeriodicalId":45630,"journal":{"name":"International Journal of Telemedicine and Applications","volume":"2016 1","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2016/3642960","citationCount":"6","resultStr":"{\"title\":\"Noninferiority and Equivalence Evaluation of Clinical Performance among Computed Radiography, Film, and Digitized Film for Telemammography Services\",\"authors\":\"A. Salazar, Javier Romero, Oscar Bernal, Angela Moreno, Sofía Velasco, Xavier A. Díaz\",\"doi\":\"10.1155/2016/3642960\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective. The aim of this study was to evaluate and compare the clinical performance of different alternatives to implement low-cost screening telemammography. We compared computed radiography, film printed images, and digitized films produced with a specialized film digitizer and a digital camera. Material and Methods. The ethics committee of our institution approved this study. We assessed the equivalence of the clinical performance of observers for cancer detection. The factorial design included 70 screening patients, four technological alternatives, and cases interpreted by seven radiologists, for a total of 1,960 observations. The variables evaluated were the positive predictive value (PPV), accuracy, sensitivity, specificity, and the area under the receiver operating characteristic curves (AUC). Result. The mean values for the observed variables were as follows: accuracy ranged from 0.77 to 0.82, the PPV ranged from 0.67 to 0.68, sensitivity ranged from 0.64 to 0.74, specificity ranged from 0.87 to 0.90, and the AUC ranged from 0.87 to 0.90. At a difference of 0.1 to claim equivalence, all alternatives were equivalent for all variables. Conclusion. Our findings suggest that telemammography screening programs may be provided to underserved populations at a low cost, using a film digitizer or a digital camera.\",\"PeriodicalId\":45630,\"journal\":{\"name\":\"International Journal of Telemedicine and Applications\",\"volume\":\"2016 1\",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2016/3642960\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Telemedicine and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2016/3642960\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Telemedicine and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2016/3642960","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
Noninferiority and Equivalence Evaluation of Clinical Performance among Computed Radiography, Film, and Digitized Film for Telemammography Services
Objective. The aim of this study was to evaluate and compare the clinical performance of different alternatives to implement low-cost screening telemammography. We compared computed radiography, film printed images, and digitized films produced with a specialized film digitizer and a digital camera. Material and Methods. The ethics committee of our institution approved this study. We assessed the equivalence of the clinical performance of observers for cancer detection. The factorial design included 70 screening patients, four technological alternatives, and cases interpreted by seven radiologists, for a total of 1,960 observations. The variables evaluated were the positive predictive value (PPV), accuracy, sensitivity, specificity, and the area under the receiver operating characteristic curves (AUC). Result. The mean values for the observed variables were as follows: accuracy ranged from 0.77 to 0.82, the PPV ranged from 0.67 to 0.68, sensitivity ranged from 0.64 to 0.74, specificity ranged from 0.87 to 0.90, and the AUC ranged from 0.87 to 0.90. At a difference of 0.1 to claim equivalence, all alternatives were equivalent for all variables. Conclusion. Our findings suggest that telemammography screening programs may be provided to underserved populations at a low cost, using a film digitizer or a digital camera.
期刊介绍:
The overall aim of the International Journal of Telemedicine and Applications is to bring together science and applications of medical practice and medical care at a distance as well as their supporting technologies such as, computing, communications, and networking technologies with emphasis on telemedicine techniques and telemedicine applications. It is directed at practicing engineers, academic researchers, as well as doctors, nurses, etc. Telemedicine is an information technology that enables doctors to perform medical consultations, diagnoses, and treatments, as well as medical education, away from patients. For example, doctors can remotely examine patients via remote viewing monitors and sound devices, and/or sampling physiological data using telecommunication. Telemedicine technology is applied to areas of emergency healthcare, videoconsulting, telecardiology, telepathology, teledermatology, teleophthalmology, teleoncology, telepsychiatry, teledentistry, etc. International Journal of Telemedicine and Applications will highlight the continued growth and new challenges in telemedicine, applications, and their supporting technologies, for both application development and basic research. Papers should emphasize original results or case studies relating to the theory and/or applications of telemedicine. Tutorial papers, especially those emphasizing multidisciplinary views of telemedicine, are also welcome. International Journal of Telemedicine and Applications employs a paperless, electronic submission and evaluation system to promote a rapid turnaround in the peer-review process.