{"title":"有效液相色谱法测定眼液中多唑胺HCl(碳酸酐酶抑制剂)含量","authors":"A. Narendra, D. Deepika, M. Annapurna","doi":"10.1155/2012/258261","DOIUrl":null,"url":null,"abstract":"A reverse phase HPLC method is described for the determination of Dorzolamide in eye drops. Chromatography was carried on an Inertsil ODS 3V column using Acetonitrile : (0.02M) 1,Octane Sulphonic acid buffer (pH 3.5) (36:64 v/v) on isocratic mode at a flow rate of 1 mL/min with UV detection at 254 nm. The detector response was linear in the concentration range 4-720 µg/mL. The limit of detection and limit of quantification are found to be 0.7041 and 2.3483 µg/mL respectively. The method was validated as per the ICH guidelines. The proposed method is rapid, accurate and precise and can be applied for the routine analysis of dorzolamide in ophthalimic solutions.","PeriodicalId":11519,"journal":{"name":"E-journal of Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2012/258261","citationCount":"2","resultStr":"{\"title\":\"Validated LC Method for the Estimation of Dorzolamide HCl (Carbonic Anhydrase Inhibitor) in Ophthalmic Solutions\",\"authors\":\"A. Narendra, D. Deepika, M. Annapurna\",\"doi\":\"10.1155/2012/258261\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A reverse phase HPLC method is described for the determination of Dorzolamide in eye drops. Chromatography was carried on an Inertsil ODS 3V column using Acetonitrile : (0.02M) 1,Octane Sulphonic acid buffer (pH 3.5) (36:64 v/v) on isocratic mode at a flow rate of 1 mL/min with UV detection at 254 nm. The detector response was linear in the concentration range 4-720 µg/mL. The limit of detection and limit of quantification are found to be 0.7041 and 2.3483 µg/mL respectively. The method was validated as per the ICH guidelines. The proposed method is rapid, accurate and precise and can be applied for the routine analysis of dorzolamide in ophthalimic solutions.\",\"PeriodicalId\":11519,\"journal\":{\"name\":\"E-journal of Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2012/258261\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"E-journal of Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2012/258261\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"E-journal of Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2012/258261","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Validated LC Method for the Estimation of Dorzolamide HCl (Carbonic Anhydrase Inhibitor) in Ophthalmic Solutions
A reverse phase HPLC method is described for the determination of Dorzolamide in eye drops. Chromatography was carried on an Inertsil ODS 3V column using Acetonitrile : (0.02M) 1,Octane Sulphonic acid buffer (pH 3.5) (36:64 v/v) on isocratic mode at a flow rate of 1 mL/min with UV detection at 254 nm. The detector response was linear in the concentration range 4-720 µg/mL. The limit of detection and limit of quantification are found to be 0.7041 and 2.3483 µg/mL respectively. The method was validated as per the ICH guidelines. The proposed method is rapid, accurate and precise and can be applied for the routine analysis of dorzolamide in ophthalimic solutions.