用于放射治疗计划的交互式计算机超声系统

E N Carlsen, J E Chrispens, W T Chu, I R Neilsen, J S Slater
{"title":"用于放射治疗计划的交互式计算机超声系统","authors":"E N Carlsen, J E Chrispens, W T Chu, I R Neilsen, J S Slater","doi":"10.1088/0031-9155/19/2/016","DOIUrl":null,"url":null,"abstract":"A diagnostic ultrasound system generates an echogram of patient contour, tumour volume and other organs. A special attachment to the scanner arm and a split table allows one to draw the complete contours. The echogram is transmitted into one of two storage scan converters and is also displayed on the video screen for immediate visual verification. The echogram is analysed by an on-line dedicated computer and the contour, tumour volume and neighbouring artifacts are identified, digitized and stored in the second scan converter, and are also displayed on a video monitor superimposed on the echogram. Radiation parameters are chosen and the resulting dose distribution is computed by a truncated external-beam program. The isodose curves are stored in the second scan converter and displayed on the video monitor superimposed on the echogram.","PeriodicalId":78434,"journal":{"name":"Medical arts and sciences","volume":"19 1","pages":"230 - 230"},"PeriodicalIF":0.0000,"publicationDate":"1974-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An interactive computer ultrasound system for radiation treatment planning\",\"authors\":\"E N Carlsen, J E Chrispens, W T Chu, I R Neilsen, J S Slater\",\"doi\":\"10.1088/0031-9155/19/2/016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A diagnostic ultrasound system generates an echogram of patient contour, tumour volume and other organs. A special attachment to the scanner arm and a split table allows one to draw the complete contours. The echogram is transmitted into one of two storage scan converters and is also displayed on the video screen for immediate visual verification. The echogram is analysed by an on-line dedicated computer and the contour, tumour volume and neighbouring artifacts are identified, digitized and stored in the second scan converter, and are also displayed on a video monitor superimposed on the echogram. Radiation parameters are chosen and the resulting dose distribution is computed by a truncated external-beam program. The isodose curves are stored in the second scan converter and displayed on the video monitor superimposed on the echogram.\",\"PeriodicalId\":78434,\"journal\":{\"name\":\"Medical arts and sciences\",\"volume\":\"19 1\",\"pages\":\"230 - 230\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1974-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical arts and sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0031-9155/19/2/016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical arts and sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0031-9155/19/2/016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

诊断超声系统生成病人轮廓、肿瘤体积和其他器官的超声图。一个特殊的连接到扫描臂和一个分裂的桌子允许绘制完整的轮廓。回声图被传输到两个存储扫描转换器中的一个,也显示在视频屏幕上,以便立即进行视觉验证。超声图由一台在线专用计算机进行分析,轮廓、肿瘤体积和邻近的伪影被识别、数字化并存储在第二扫描转换器中,并显示在叠加在超声图上的视频监视器上。选择辐射参数,并通过截断外束程序计算得到的剂量分布。等剂量曲线存储在第二扫描转换器中,并显示在叠加在回声图上的视频监视器上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An interactive computer ultrasound system for radiation treatment planning
A diagnostic ultrasound system generates an echogram of patient contour, tumour volume and other organs. A special attachment to the scanner arm and a split table allows one to draw the complete contours. The echogram is transmitted into one of two storage scan converters and is also displayed on the video screen for immediate visual verification. The echogram is analysed by an on-line dedicated computer and the contour, tumour volume and neighbouring artifacts are identified, digitized and stored in the second scan converter, and are also displayed on a video monitor superimposed on the echogram. Radiation parameters are chosen and the resulting dose distribution is computed by a truncated external-beam program. The isodose curves are stored in the second scan converter and displayed on the video monitor superimposed on the echogram.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信