Eschenbach制造的“头部和附件放大镜”的放大倍率和工作距离

T. Tanabe, H. Uozato, K. Tsuji
{"title":"Eschenbach制造的“头部和附件放大镜”的放大倍率和工作距离","authors":"T. Tanabe, H. Uozato, K. Tsuji","doi":"10.1080/13882350701608973","DOIUrl":null,"url":null,"abstract":"Purpose: Because magnification ratios (MRs) indicated (IMRs) in catalogues of “Head and Attachment Magnifiers” made by Eschenbach are not common values, we examined the IMRs in relation to the working distances (WDs) indicated (IWDs) in the catalogues and then calculated the corrected WDs. Methods: From information about loupes given in the catalogues and measurements made with a lensometer, we determined (1) the power of each magnifier and (2) the accommodation needed; we then (3) calculated the MR and (4) established the corrected WD. Results: When used within the IWD, monocular loupe had an MR that was the same as the IMR. However, for binocular loupes, the MR was lower than the IMR. When the loupes were used at the revised WD recommended by the engineer of Eschenbach, binocular loupes had an IMR of “–1,” meaning that a WD shorter than the revised WD was needed to attain the IMR. Conclusion: With Eschenbach head and attachment magnifiers, the IMR is only attained when viewed at a shorter WD than that i...","PeriodicalId":88340,"journal":{"name":"Visual impairment research","volume":"9 1","pages":"51-57"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/13882350701608973","citationCount":"0","resultStr":"{\"title\":\"Magnification Ratios and Working Distances of “Head and Attachment Magnifiers” Made by Eschenbach\",\"authors\":\"T. Tanabe, H. Uozato, K. Tsuji\",\"doi\":\"10.1080/13882350701608973\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: Because magnification ratios (MRs) indicated (IMRs) in catalogues of “Head and Attachment Magnifiers” made by Eschenbach are not common values, we examined the IMRs in relation to the working distances (WDs) indicated (IWDs) in the catalogues and then calculated the corrected WDs. Methods: From information about loupes given in the catalogues and measurements made with a lensometer, we determined (1) the power of each magnifier and (2) the accommodation needed; we then (3) calculated the MR and (4) established the corrected WD. Results: When used within the IWD, monocular loupe had an MR that was the same as the IMR. However, for binocular loupes, the MR was lower than the IMR. When the loupes were used at the revised WD recommended by the engineer of Eschenbach, binocular loupes had an IMR of “–1,” meaning that a WD shorter than the revised WD was needed to attain the IMR. Conclusion: With Eschenbach head and attachment magnifiers, the IMR is only attained when viewed at a shorter WD than that i...\",\"PeriodicalId\":88340,\"journal\":{\"name\":\"Visual impairment research\",\"volume\":\"9 1\",\"pages\":\"51-57\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/13882350701608973\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Visual impairment research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/13882350701608973\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Visual impairment research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/13882350701608973","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:由于Eschenbach制作的“头部和附件放大镜”目录中显示的放大倍率(mr) (IMRs)不是通用值,我们检查了与目录中显示的工作距离(WDs) (IWDs)相关的放大倍率(mr),然后计算校正后的WDs。方法:根据目录中给出的放大镜信息和用透镜计测量的结果,我们确定了(1)每个放大镜的功率和(2)所需的调节;然后(3)计算MR,(4)建立校正WD。结果:在内窥镜内使用时,单眼镜的MR与内窥镜相同。然而,对于双目镜,MR低于IMR。当镜在Eschenbach工程师推荐的修正WD下使用时,双眼镜的IMR为“-1”,这意味着需要比修正WD短的WD来达到IMR。结论:使用Eschenbach头和附着放大镜,只有在较短的WD下才能获得IMR。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Magnification Ratios and Working Distances of “Head and Attachment Magnifiers” Made by Eschenbach
Purpose: Because magnification ratios (MRs) indicated (IMRs) in catalogues of “Head and Attachment Magnifiers” made by Eschenbach are not common values, we examined the IMRs in relation to the working distances (WDs) indicated (IWDs) in the catalogues and then calculated the corrected WDs. Methods: From information about loupes given in the catalogues and measurements made with a lensometer, we determined (1) the power of each magnifier and (2) the accommodation needed; we then (3) calculated the MR and (4) established the corrected WD. Results: When used within the IWD, monocular loupe had an MR that was the same as the IMR. However, for binocular loupes, the MR was lower than the IMR. When the loupes were used at the revised WD recommended by the engineer of Eschenbach, binocular loupes had an IMR of “–1,” meaning that a WD shorter than the revised WD was needed to attain the IMR. Conclusion: With Eschenbach head and attachment magnifiers, the IMR is only attained when viewed at a shorter WD than that i...
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信