{"title":"醒着和睡着的人的振幅调制反应——40hz和80hz调制频率的比较","authors":"J. Pethe, H. Specht, R. Mühler, T. Hocke","doi":"10.1080/010503901300007371","DOIUrl":null,"url":null,"abstract":"There have been several studies, which suggest that the amplitude of amplitude modulation following responses (AMFR) is correlated to the state of vigilance, similar to the 40 Hz event-related potentials. The aim of the present study was to compare the dependency of the AMFR-amplitude from the state of sleep for 40 Hz and 80 Hz modulation frequency. Eight normal hearing adults were investigated during natural and drug-induced sleep. The stimuli used were sinusoidally amplitude-modulated tones of 1 kHz carried frequency and 40 or 80 Hz modulation frequency at 60 dB nH stimulation level. For 40 Hz modulation frequency an increase of EEG-activity in the Delta-and Theta-band during periods of sleep correlates significantly with a decreased AMFR-amplitude whereas for 80 Hz no significant relation between stage of sleep and AMFR-amplitude could be found. The results suggest that in audiological use of 40 Hz-AMFR the state of vigilance should be monitored and stabilized at a high level.","PeriodicalId":76516,"journal":{"name":"Scandinavian audiology","volume":"30 1","pages":"152 - 155"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/010503901300007371","citationCount":"24","resultStr":"{\"title\":\"Amplitude modulation following responses in awake and sleeping humans - a comparison for 40 Hz and 80 Hz modulation frequency\",\"authors\":\"J. Pethe, H. Specht, R. Mühler, T. Hocke\",\"doi\":\"10.1080/010503901300007371\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There have been several studies, which suggest that the amplitude of amplitude modulation following responses (AMFR) is correlated to the state of vigilance, similar to the 40 Hz event-related potentials. The aim of the present study was to compare the dependency of the AMFR-amplitude from the state of sleep for 40 Hz and 80 Hz modulation frequency. Eight normal hearing adults were investigated during natural and drug-induced sleep. The stimuli used were sinusoidally amplitude-modulated tones of 1 kHz carried frequency and 40 or 80 Hz modulation frequency at 60 dB nH stimulation level. For 40 Hz modulation frequency an increase of EEG-activity in the Delta-and Theta-band during periods of sleep correlates significantly with a decreased AMFR-amplitude whereas for 80 Hz no significant relation between stage of sleep and AMFR-amplitude could be found. The results suggest that in audiological use of 40 Hz-AMFR the state of vigilance should be monitored and stabilized at a high level.\",\"PeriodicalId\":76516,\"journal\":{\"name\":\"Scandinavian audiology\",\"volume\":\"30 1\",\"pages\":\"152 - 155\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/010503901300007371\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/010503901300007371\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/010503901300007371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24
摘要
有几项研究表明,振幅调制跟随反应(AMFR)的振幅与警觉性状态相关,类似于40 Hz事件相关电位。本研究的目的是比较睡眠状态下amfr振幅对40hz和80hz调制频率的依赖性。8名听力正常的成年人在自然睡眠和药物诱导睡眠中进行了调查。使用的刺激是1 kHz携带频率和40或80 Hz调制频率的正弦调幅音调,60 dB nH刺激水平。当调制频率为40 Hz时,睡眠期间delta和theta波段脑电图活动的增加与amfr振幅的下降显著相关,而当调制频率为80 Hz时,睡眠阶段与amfr振幅之间没有显著关系。结果提示,在听力学使用40hz - amfr时,应监测并保持高警戒状态。
Amplitude modulation following responses in awake and sleeping humans - a comparison for 40 Hz and 80 Hz modulation frequency
There have been several studies, which suggest that the amplitude of amplitude modulation following responses (AMFR) is correlated to the state of vigilance, similar to the 40 Hz event-related potentials. The aim of the present study was to compare the dependency of the AMFR-amplitude from the state of sleep for 40 Hz and 80 Hz modulation frequency. Eight normal hearing adults were investigated during natural and drug-induced sleep. The stimuli used were sinusoidally amplitude-modulated tones of 1 kHz carried frequency and 40 or 80 Hz modulation frequency at 60 dB nH stimulation level. For 40 Hz modulation frequency an increase of EEG-activity in the Delta-and Theta-band during periods of sleep correlates significantly with a decreased AMFR-amplitude whereas for 80 Hz no significant relation between stage of sleep and AMFR-amplitude could be found. The results suggest that in audiological use of 40 Hz-AMFR the state of vigilance should be monitored and stabilized at a high level.