{"title":"受污染的一次性橡胶手套作为神经毒剂化学袭击后的证据样本","authors":"Tomas Rozsypal","doi":"10.1002/dta.3468","DOIUrl":null,"url":null,"abstract":"<p>Nerve agents have been used recently in the Syrian civil war. Collecting relevant samples for retrospective identification of an attack is often problematic. The article deals with the possibility of using contaminated gloves as an analytical sample for evidence of the chemical weapons use. There have not yet been published studies dealing with the identification of chemical warfare agents in this type of matrix, where the diversity of chemical properties of gloves and the lifetime of the contaminated sample would be considered. Sarin, soman, and cyclosarin were used as contaminants in the study. Nitrile, latex, and vinyl disposable gloves were chosen as matrices. The identification method was gas chromatography. Six solvents commonly used in military laboratories were tested as extractants. The extraction procedure was optimized in terms of the appropriate method (vortex) and the required extraction time (1 min) and resulted in significant reduction in sample preparation time. The chromatographic background of the extracts was also monitored in order to find a method with the least number of peaks interfering in the identification. Suitable solvents were hexane and acetonitrile. The lifetime of the sample was also investigated. The worst result was recorded for latex. For individual contaminants, the time varied depending on the volatility. The developed procedures were successfully validated within a sample handling effects scenario. The results demonstrate that in the event of an ongoing military risk at the site of an attack, even discarded disposable rubber glove type samples can be used as evidence.</p>","PeriodicalId":160,"journal":{"name":"Drug Testing and Analysis","volume":"15 7","pages":"745-756"},"PeriodicalIF":2.6000,"publicationDate":"2023-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Contaminated disposable rubber gloves as evidence samples after a chemical attack with nerve agents\",\"authors\":\"Tomas Rozsypal\",\"doi\":\"10.1002/dta.3468\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Nerve agents have been used recently in the Syrian civil war. Collecting relevant samples for retrospective identification of an attack is often problematic. The article deals with the possibility of using contaminated gloves as an analytical sample for evidence of the chemical weapons use. There have not yet been published studies dealing with the identification of chemical warfare agents in this type of matrix, where the diversity of chemical properties of gloves and the lifetime of the contaminated sample would be considered. Sarin, soman, and cyclosarin were used as contaminants in the study. Nitrile, latex, and vinyl disposable gloves were chosen as matrices. The identification method was gas chromatography. Six solvents commonly used in military laboratories were tested as extractants. The extraction procedure was optimized in terms of the appropriate method (vortex) and the required extraction time (1 min) and resulted in significant reduction in sample preparation time. The chromatographic background of the extracts was also monitored in order to find a method with the least number of peaks interfering in the identification. Suitable solvents were hexane and acetonitrile. The lifetime of the sample was also investigated. The worst result was recorded for latex. For individual contaminants, the time varied depending on the volatility. The developed procedures were successfully validated within a sample handling effects scenario. The results demonstrate that in the event of an ongoing military risk at the site of an attack, even discarded disposable rubber glove type samples can be used as evidence.</p>\",\"PeriodicalId\":160,\"journal\":{\"name\":\"Drug Testing and Analysis\",\"volume\":\"15 7\",\"pages\":\"745-756\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drug Testing and Analysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/dta.3468\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Testing and Analysis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/dta.3468","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Contaminated disposable rubber gloves as evidence samples after a chemical attack with nerve agents
Nerve agents have been used recently in the Syrian civil war. Collecting relevant samples for retrospective identification of an attack is often problematic. The article deals with the possibility of using contaminated gloves as an analytical sample for evidence of the chemical weapons use. There have not yet been published studies dealing with the identification of chemical warfare agents in this type of matrix, where the diversity of chemical properties of gloves and the lifetime of the contaminated sample would be considered. Sarin, soman, and cyclosarin were used as contaminants in the study. Nitrile, latex, and vinyl disposable gloves were chosen as matrices. The identification method was gas chromatography. Six solvents commonly used in military laboratories were tested as extractants. The extraction procedure was optimized in terms of the appropriate method (vortex) and the required extraction time (1 min) and resulted in significant reduction in sample preparation time. The chromatographic background of the extracts was also monitored in order to find a method with the least number of peaks interfering in the identification. Suitable solvents were hexane and acetonitrile. The lifetime of the sample was also investigated. The worst result was recorded for latex. For individual contaminants, the time varied depending on the volatility. The developed procedures were successfully validated within a sample handling effects scenario. The results demonstrate that in the event of an ongoing military risk at the site of an attack, even discarded disposable rubber glove type samples can be used as evidence.
期刊介绍:
As the incidence of drugs escalates in 21st century living, their detection and analysis have become increasingly important. Sport, the workplace, crime investigation, homeland security, the pharmaceutical industry and the environment are just some of the high profile arenas in which analytical testing has provided an important investigative tool for uncovering the presence of extraneous substances.
In addition to the usual publishing fare of primary research articles, case reports and letters, Drug Testing and Analysis offers a unique combination of; ‘How to’ material such as ‘Tutorials’ and ‘Reviews’, Speculative pieces (‘Commentaries’ and ‘Perspectives'', providing a broader scientific and social context to the aspects of analytical testing), ‘Annual banned substance reviews’ (delivering a critical evaluation of the methods used in the characterization of established and newly outlawed compounds).
Rather than focus on the application of a single technique, Drug Testing and Analysis employs a unique multidisciplinary approach to the field of controversial compound determination. Papers discussing chromatography, mass spectrometry, immunological approaches, 1D/2D gel electrophoresis, to name just a few select methods, are welcomed where their application is related to any of the six key topics listed below.