C. Juarez , F. Rumiche , A. Rozas , J. Cuisano , P. Lean
{"title":"柴油发电机连杆失效分析","authors":"C. Juarez , F. Rumiche , A. Rozas , J. Cuisano , P. Lean","doi":"10.1016/j.csefa.2016.06.001","DOIUrl":null,"url":null,"abstract":"<div><p>This paper presents the results of a failure analysis investigation conducted in a connecting rod from a diesel engine used in the generation of electrical energy. The investigation included an extensive analysis of the con-rod material as well as the fracture zone. The investigation involved the following experimental procedures and testing techniques: visual inspection, fractography, magnetic particle inspection, chemical analysis, tensile and hardness testing, metallography, and microanalysis. The connecting rod was fabricated from an AISI/SAE 4140 low alloy steel; chemical composition, mechanical properties and microstructure were appropriate for the application. The connecting rod fractured at the body in a section close to the head; the origin of the fracture was located at the con-rod lubrication channel. The lubrication channel exhibited an area containing a tungsten based material, presumably from a machining tool, embedded in its surface as a result of a deficient manufacturing process. This area acted as nucleation site for cracks that propagate through the connecting rod section by a fatigue mechanism, reducing its section and finally producing its catastrophic failure.</p></div>","PeriodicalId":91224,"journal":{"name":"Case studies in engineering failure analysis","volume":"7 ","pages":"Pages 24-31"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.csefa.2016.06.001","citationCount":"24","resultStr":"{\"title\":\"Failure analysis of a diesel generator connecting rod\",\"authors\":\"C. Juarez , F. Rumiche , A. Rozas , J. Cuisano , P. Lean\",\"doi\":\"10.1016/j.csefa.2016.06.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This paper presents the results of a failure analysis investigation conducted in a connecting rod from a diesel engine used in the generation of electrical energy. The investigation included an extensive analysis of the con-rod material as well as the fracture zone. The investigation involved the following experimental procedures and testing techniques: visual inspection, fractography, magnetic particle inspection, chemical analysis, tensile and hardness testing, metallography, and microanalysis. The connecting rod was fabricated from an AISI/SAE 4140 low alloy steel; chemical composition, mechanical properties and microstructure were appropriate for the application. The connecting rod fractured at the body in a section close to the head; the origin of the fracture was located at the con-rod lubrication channel. The lubrication channel exhibited an area containing a tungsten based material, presumably from a machining tool, embedded in its surface as a result of a deficient manufacturing process. This area acted as nucleation site for cracks that propagate through the connecting rod section by a fatigue mechanism, reducing its section and finally producing its catastrophic failure.</p></div>\",\"PeriodicalId\":91224,\"journal\":{\"name\":\"Case studies in engineering failure analysis\",\"volume\":\"7 \",\"pages\":\"Pages 24-31\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.csefa.2016.06.001\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Case studies in engineering failure analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2213290216300098\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case studies in engineering failure analysis","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213290216300098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Failure analysis of a diesel generator connecting rod
This paper presents the results of a failure analysis investigation conducted in a connecting rod from a diesel engine used in the generation of electrical energy. The investigation included an extensive analysis of the con-rod material as well as the fracture zone. The investigation involved the following experimental procedures and testing techniques: visual inspection, fractography, magnetic particle inspection, chemical analysis, tensile and hardness testing, metallography, and microanalysis. The connecting rod was fabricated from an AISI/SAE 4140 low alloy steel; chemical composition, mechanical properties and microstructure were appropriate for the application. The connecting rod fractured at the body in a section close to the head; the origin of the fracture was located at the con-rod lubrication channel. The lubrication channel exhibited an area containing a tungsten based material, presumably from a machining tool, embedded in its surface as a result of a deficient manufacturing process. This area acted as nucleation site for cracks that propagate through the connecting rod section by a fatigue mechanism, reducing its section and finally producing its catastrophic failure.