二维三相喷床中的气含率

Mohammed Z. Anabtawi, Bekir Z. Uysal
{"title":"二维三相喷床中的气含率","authors":"Mohammed Z. Anabtawi,&nbsp;Bekir Z. Uysal","doi":"10.1016/0300-9467(92)80021-2","DOIUrl":null,"url":null,"abstract":"<div><p>Gas hold-up in a bi-dimensional three-phase spouted bed, operated continuously with respect to the gas flow and batchwise with respect to liquid and solid, was investigated using a bed expansion technique. Experiments were performed in a column of 22 mm × 220 mm × 1250 mm. Sand particles 1.0 mm in diameter, solid fractions 0.05, 0.10, 0.15 and 0.20, five different nozzle sizes (4.0 mm, 5.5 mm, 7.0 mm, 10.0 mm and 12.0 mm), four static bed heights (0.17 m, 0.32 m, 0.58 m and 0.69 m) and superficial gas velocities ranging from 0.34 to 3.43 m s<sup>−1</sup> were employed. A correlation for the gas hold-up was developed with an average deviation of 2.5% and maximum deviation not exceeding 9%.</p></div>","PeriodicalId":101225,"journal":{"name":"The Chemical Engineering Journal","volume":"50 3","pages":"Pages 143-147"},"PeriodicalIF":0.0000,"publicationDate":"1992-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0300-9467(92)80021-2","citationCount":"6","resultStr":"{\"title\":\"Gas hold-up in a bi-dimensional three-phase spouted bed\",\"authors\":\"Mohammed Z. Anabtawi,&nbsp;Bekir Z. Uysal\",\"doi\":\"10.1016/0300-9467(92)80021-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Gas hold-up in a bi-dimensional three-phase spouted bed, operated continuously with respect to the gas flow and batchwise with respect to liquid and solid, was investigated using a bed expansion technique. Experiments were performed in a column of 22 mm × 220 mm × 1250 mm. Sand particles 1.0 mm in diameter, solid fractions 0.05, 0.10, 0.15 and 0.20, five different nozzle sizes (4.0 mm, 5.5 mm, 7.0 mm, 10.0 mm and 12.0 mm), four static bed heights (0.17 m, 0.32 m, 0.58 m and 0.69 m) and superficial gas velocities ranging from 0.34 to 3.43 m s<sup>−1</sup> were employed. A correlation for the gas hold-up was developed with an average deviation of 2.5% and maximum deviation not exceeding 9%.</p></div>\",\"PeriodicalId\":101225,\"journal\":{\"name\":\"The Chemical Engineering Journal\",\"volume\":\"50 3\",\"pages\":\"Pages 143-147\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0300-9467(92)80021-2\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Chemical Engineering Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0300946792800212\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Chemical Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0300946792800212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

采用床层膨胀技术,研究了二维三相喷淋床的气含率。实验柱为22 mm × 220 mm × 1250 mm。砂粒直径为1.0 mm,固体组分为0.05、0.10、0.15和0.20,喷嘴尺寸为4.0 mm、5.5 mm、7.0 mm、10.0 mm和12.0 mm,静态床层高度为0.17 m、0.32 m、0.58 m和0.69 m,表面气速为0.34 ~ 3.43 m s - 1。建立了气含率的相关性,平均偏差为2.5%,最大偏差不超过9%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Gas hold-up in a bi-dimensional three-phase spouted bed

Gas hold-up in a bi-dimensional three-phase spouted bed, operated continuously with respect to the gas flow and batchwise with respect to liquid and solid, was investigated using a bed expansion technique. Experiments were performed in a column of 22 mm × 220 mm × 1250 mm. Sand particles 1.0 mm in diameter, solid fractions 0.05, 0.10, 0.15 and 0.20, five different nozzle sizes (4.0 mm, 5.5 mm, 7.0 mm, 10.0 mm and 12.0 mm), four static bed heights (0.17 m, 0.32 m, 0.58 m and 0.69 m) and superficial gas velocities ranging from 0.34 to 3.43 m s−1 were employed. A correlation for the gas hold-up was developed with an average deviation of 2.5% and maximum deviation not exceeding 9%.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信