护理点设备MZI结构中BCB和SU 8光子波导的分析

S. Prasanna Kumaar, A. Sivasubramanian
{"title":"护理点设备MZI结构中BCB和SU 8光子波导的分析","authors":"S. Prasanna Kumaar,&nbsp;A. Sivasubramanian","doi":"10.1016/j.sintl.2022.100207","DOIUrl":null,"url":null,"abstract":"<div><p>The proposed refractive index-based biosensor made of cost-effective polymer material in Mach-Zehnder configuration with novel horizontal slot waveguide structure offers high sensitivity. Due to the recent demand for low-cost point-of-care biosensor, silicon wafer-based polymer material has the potential for developing new hybrid waveguides for sensors. Hence we designed BenzoCycloButene (BCB), SU8 material as the core, and polymethyl methacrylate (PMMA) clad on a silicon wafer. The novelty of proposed BCB and SU8 horizontal slot waveguide structure of 2.5 <span><math><mrow><mi>μ</mi></mrow></math></span> m wide and 1.<span><math><mrow><mn>8</mn><mi>μ</mi></mrow></math></span> m thick with a slot height of 400 ​nm, which handles the analyte effectively without any external sample holder. In Mach-Zehnder Interferometer architecture, reference arm 1 ​cm and sensing arm at a length of 1.1 ​cm with analyte refractive index of cancer cell (RI ​= ​1.401) and Influenza A type virus (RI ​= ​1.48) are used. Effective mode index of BCB core and SU8 are investigated through Finite-difference time domain (FDTD) analysis, and sensitivity results are calculated. Detection of disease are plotted in the transmission spectrum with reference to normal human serum (RI ​= ​1.35). This horizontal slot waveguide of BCB core achieves a sensitivity of 19280 nm/RIU and SU8 horizontal slot core waveguide provides a sensitivity of 16500 nm/RIU, which is higher in this polymer based refractive index biosensing.</p></div>","PeriodicalId":21733,"journal":{"name":"Sensors International","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of BCB and SU 8 photonic waveguide in MZI architecture for point-of-care devices\",\"authors\":\"S. Prasanna Kumaar,&nbsp;A. Sivasubramanian\",\"doi\":\"10.1016/j.sintl.2022.100207\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The proposed refractive index-based biosensor made of cost-effective polymer material in Mach-Zehnder configuration with novel horizontal slot waveguide structure offers high sensitivity. Due to the recent demand for low-cost point-of-care biosensor, silicon wafer-based polymer material has the potential for developing new hybrid waveguides for sensors. Hence we designed BenzoCycloButene (BCB), SU8 material as the core, and polymethyl methacrylate (PMMA) clad on a silicon wafer. The novelty of proposed BCB and SU8 horizontal slot waveguide structure of 2.5 <span><math><mrow><mi>μ</mi></mrow></math></span> m wide and 1.<span><math><mrow><mn>8</mn><mi>μ</mi></mrow></math></span> m thick with a slot height of 400 ​nm, which handles the analyte effectively without any external sample holder. In Mach-Zehnder Interferometer architecture, reference arm 1 ​cm and sensing arm at a length of 1.1 ​cm with analyte refractive index of cancer cell (RI ​= ​1.401) and Influenza A type virus (RI ​= ​1.48) are used. Effective mode index of BCB core and SU8 are investigated through Finite-difference time domain (FDTD) analysis, and sensitivity results are calculated. Detection of disease are plotted in the transmission spectrum with reference to normal human serum (RI ​= ​1.35). This horizontal slot waveguide of BCB core achieves a sensitivity of 19280 nm/RIU and SU8 horizontal slot core waveguide provides a sensitivity of 16500 nm/RIU, which is higher in this polymer based refractive index biosensing.</p></div>\",\"PeriodicalId\":21733,\"journal\":{\"name\":\"Sensors International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666351122000523\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666351122000523","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

所提出的基于折射率的生物传感器由Mach-Zehnder配置的成本效益高的聚合物材料制成,具有新颖的水平缝隙波导结构,具有高灵敏度。由于最近对低成本护理点生物传感器的需求,基于硅片的聚合物材料具有开发用于传感器的新型混合波导的潜力。因此,我们设计了苯并环丁烯(BCB),SU8材料为核心,聚甲基丙烯酸甲酯(PMMA)覆盖在硅片上。所提出的2.5μm宽、1.8μm厚、槽高为400的BCB和SU8水平槽波导结构的新颖性​nm,其在没有任何外部样品支架的情况下有效地处理分析物。在马赫-曾德尔干涉仪结构中,参考臂1​cm,传感臂长度为1.1​cm与癌症细胞的分析物折射率(RI​=​1.401)和甲型流感病毒(RI​=​1.48)。通过时域有限差分(FDTD)分析,研究了BCB核心和SU8的有效模指数,并计算了灵敏度结果。参照正常人血清在透射光谱中绘制疾病检测图(RI​=​1.35)。BCB芯的这种水平槽波导实现了19280nm/RIU的灵敏度,并且SU8水平槽芯波导提供了16500nm/RIU的灵敏度,这在这种基于聚合物的折射率生物传感中更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Analysis of BCB and SU 8 photonic waveguide in MZI architecture for point-of-care devices

Analysis of BCB and SU 8 photonic waveguide in MZI architecture for point-of-care devices

The proposed refractive index-based biosensor made of cost-effective polymer material in Mach-Zehnder configuration with novel horizontal slot waveguide structure offers high sensitivity. Due to the recent demand for low-cost point-of-care biosensor, silicon wafer-based polymer material has the potential for developing new hybrid waveguides for sensors. Hence we designed BenzoCycloButene (BCB), SU8 material as the core, and polymethyl methacrylate (PMMA) clad on a silicon wafer. The novelty of proposed BCB and SU8 horizontal slot waveguide structure of 2.5 μ m wide and 1.8μ m thick with a slot height of 400 ​nm, which handles the analyte effectively without any external sample holder. In Mach-Zehnder Interferometer architecture, reference arm 1 ​cm and sensing arm at a length of 1.1 ​cm with analyte refractive index of cancer cell (RI ​= ​1.401) and Influenza A type virus (RI ​= ​1.48) are used. Effective mode index of BCB core and SU8 are investigated through Finite-difference time domain (FDTD) analysis, and sensitivity results are calculated. Detection of disease are plotted in the transmission spectrum with reference to normal human serum (RI ​= ​1.35). This horizontal slot waveguide of BCB core achieves a sensitivity of 19280 nm/RIU and SU8 horizontal slot core waveguide provides a sensitivity of 16500 nm/RIU, which is higher in this polymer based refractive index biosensing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
17.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信