{"title":"胫骨远端前外侧钢板固定过程中胫骨前动脉危险区:三维CT血管造影建模研究。","authors":"Brendan O'Leary, Brendon Mitchell, Sean Thomas, Keenan Onodera, Brady Huang, William T Kent","doi":"10.1097/BOT.0000000000002718","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The objective of this study was to define the danger zone at which the anterior tibial artery (ATA) is at risk during anterolateral plating of the distal tibia using a novel 3D computed tomography angiography (CTA) modeling technique.</p><p><strong>Methods: </strong>116 patients (232 lower extremities) who underwent lower extremity CTAs between April 2020 and April 2022 were identified. Those with lower extremity trauma, evidence of a previously healed tibial fracture, or poor visualization of the ATA were excluded. The remaining 150 lower extremities (92 patients) were modeled with an anterolateral distal tibia plate using Sectra IDS7 software. The distance of the ATA from bony landmarks was measured perpendicular to the level at which the vessel intersected the plate.</p><p><strong>Results: </strong>The ATA intersected the plate proximally at a mean distance of 10.5 cm (95% confidence intervals, 10.2-10.9) and at a mean distance of 4.6 cm (95% confidence intervals, 4.4-4.9) distally from the central tibial plafond. The ATA intersected with the plate as far distal as hole number 1 and as proximal as hole 14 of the plate. The greatest injury risk was associated with plate holes 3-8. In this region, the artery was at risk in 46-99 percent of specimens.</p><p><strong>Conclusions: </strong>The ATA is at risk when screws are placed percutaneously in an anterolateral distal tibia plate. The artery can be as close as 4.4 cm and as far as 10.9 cm proximal to the tibial plafond when crossing the plate, correlating to a risk of injury to the ATA at plate holes 1 through 14.</p>","PeriodicalId":16644,"journal":{"name":"Journal of Orthopaedic Trauma","volume":" ","pages":"e15-e19"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Anterior Tibial Artery Danger Zone During Anterolateral Plate Fixation of the Distal Tibia: A 3D Computed Tomography Angiogram Modeling Study.\",\"authors\":\"Brendan O'Leary, Brendon Mitchell, Sean Thomas, Keenan Onodera, Brady Huang, William T Kent\",\"doi\":\"10.1097/BOT.0000000000002718\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The objective of this study was to define the danger zone at which the anterior tibial artery (ATA) is at risk during anterolateral plating of the distal tibia using a novel 3D computed tomography angiography (CTA) modeling technique.</p><p><strong>Methods: </strong>116 patients (232 lower extremities) who underwent lower extremity CTAs between April 2020 and April 2022 were identified. Those with lower extremity trauma, evidence of a previously healed tibial fracture, or poor visualization of the ATA were excluded. The remaining 150 lower extremities (92 patients) were modeled with an anterolateral distal tibia plate using Sectra IDS7 software. The distance of the ATA from bony landmarks was measured perpendicular to the level at which the vessel intersected the plate.</p><p><strong>Results: </strong>The ATA intersected the plate proximally at a mean distance of 10.5 cm (95% confidence intervals, 10.2-10.9) and at a mean distance of 4.6 cm (95% confidence intervals, 4.4-4.9) distally from the central tibial plafond. The ATA intersected with the plate as far distal as hole number 1 and as proximal as hole 14 of the plate. The greatest injury risk was associated with plate holes 3-8. In this region, the artery was at risk in 46-99 percent of specimens.</p><p><strong>Conclusions: </strong>The ATA is at risk when screws are placed percutaneously in an anterolateral distal tibia plate. The artery can be as close as 4.4 cm and as far as 10.9 cm proximal to the tibial plafond when crossing the plate, correlating to a risk of injury to the ATA at plate holes 1 through 14.</p>\",\"PeriodicalId\":16644,\"journal\":{\"name\":\"Journal of Orthopaedic Trauma\",\"volume\":\" \",\"pages\":\"e15-e19\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Trauma\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/BOT.0000000000002718\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Trauma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BOT.0000000000002718","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是使用一种新的三维CTA建模技术来确定胫骨远端前外侧钢板植入过程中胫骨前动脉(ATA)处于危险区域。方法:我们确定了在2020年4月至2022年4月期间进行下肢CTA的116名患者(232名下肢)。那些有下肢创伤、胫骨骨折先前愈合的证据或ATA可视化较差的患者被排除在外。其余150个下肢(92名患者)使用Sectra IDS7软件用胫骨前外侧远端钢板进行建模。ATA与骨标志的距离是垂直于血管与钢板相交的水平测量的。结果:ATA与胫骨中央板的近端平均距离为10.5cm(95%CI 10.2-10.9),远端平均距离为4.6cm(95%CI4.4-4.9)。ATA与板相交,远至孔1,近至板的孔14。最大的受伤风险与钢板孔3-8有关。在这个区域,46-99%的标本中动脉处于危险之中。结论:经皮在胫骨前外侧远端钢板内放置螺钉时,ATA有风险。当穿过钢板时,动脉可能接近胫骨平台4.4厘米,最远可达10.9厘米,这与钢板孔1至14处ATA受伤的风险相关。证据级别:IV级,计算机断层扫描血管造影术研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Anterior Tibial Artery Danger Zone During Anterolateral Plate Fixation of the Distal Tibia: A 3D Computed Tomography Angiogram Modeling Study.

Objectives: The objective of this study was to define the danger zone at which the anterior tibial artery (ATA) is at risk during anterolateral plating of the distal tibia using a novel 3D computed tomography angiography (CTA) modeling technique.

Methods: 116 patients (232 lower extremities) who underwent lower extremity CTAs between April 2020 and April 2022 were identified. Those with lower extremity trauma, evidence of a previously healed tibial fracture, or poor visualization of the ATA were excluded. The remaining 150 lower extremities (92 patients) were modeled with an anterolateral distal tibia plate using Sectra IDS7 software. The distance of the ATA from bony landmarks was measured perpendicular to the level at which the vessel intersected the plate.

Results: The ATA intersected the plate proximally at a mean distance of 10.5 cm (95% confidence intervals, 10.2-10.9) and at a mean distance of 4.6 cm (95% confidence intervals, 4.4-4.9) distally from the central tibial plafond. The ATA intersected with the plate as far distal as hole number 1 and as proximal as hole 14 of the plate. The greatest injury risk was associated with plate holes 3-8. In this region, the artery was at risk in 46-99 percent of specimens.

Conclusions: The ATA is at risk when screws are placed percutaneously in an anterolateral distal tibia plate. The artery can be as close as 4.4 cm and as far as 10.9 cm proximal to the tibial plafond when crossing the plate, correlating to a risk of injury to the ATA at plate holes 1 through 14.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthopaedic Trauma
Journal of Orthopaedic Trauma 医学-运动科学
CiteScore
3.90
自引率
8.70%
发文量
396
审稿时长
3-8 weeks
期刊介绍: Journal of Orthopaedic Trauma is devoted exclusively to the diagnosis and management of hard and soft tissue trauma, including injuries to bone, muscle, ligament, and tendons, as well as spinal cord injuries. Under the guidance of a distinguished international board of editors, the journal provides the most current information on diagnostic techniques, new and improved surgical instruments and procedures, surgical implants and prosthetic devices, bioplastics and biometals; and physical therapy and rehabilitation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信