{"title":"超声内镜引导下游离性胰腺坏死引流术中“碎片评估”的观察者间共识","authors":"Partha Pal , Sundeep Lakhtakia , Nitin Jagtap , Shujaath Asif , Krithi Krishna Koduri , Rajesh Gupta , Jahangeer Basha , Azimudin Haja , Aniruddha Pratap Singh , Ashirwad Pasumarthy , Zaheer Nabi , Jagdeesh Rampal Singh , Rakesh Kalpala , Mohan Ramchandani , D Nageshwar Reddy","doi":"10.1016/j.tige.2023.03.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and Aims</h3><p>Estimation of the solid component in walled-off pancreatic necrosis<span> (WOPN) during endoscopic ultrasound (EUS) is an important parameter to guide the selection of stent for drainage but is often not objectively quantified.</span></p></div><div><h3>Methods</h3><p>We aimed to study the interobserver agreement (IOA) among endosonographers assessing debris in the pancreatic fluid collection and their choice of stent. EUS videos of 15 patients having pancreatic fluid collection with concurrent magnetic resonance imaging (MRI) assessment of debris were independently reviewed by 40 endosonographers for the percentage of debris (10% increments) and their choice of stent (plastic or metal). The Fleiss kappa (κ) coefficient was used to assess IOA. Post-hoc analysis was done using wider debris intervals (20% or greater increments).</p></div><div><h3>Results</h3><p>Poor agreement was observed for the percentage of debris (κ = 0.188), which did not improve (κ = 0.196) even after including only expert endosonographers with more than 10 years of experience (n = 33). There was fair agreement (κ = 0.266) with reference MRI on the percentage of debris. On post-hoc analysis, the IOA (κ = 0.56, substantial agreement) and agreement with MRI (κ = 0.59, substantial agreement) improved as the debris intervals widened (<10%, 10%-50%, >50%). The agreement for stent selection (plastic vs metal) was poor (κ = 0.174) and did not improve with case volume (κ = 0.153 among respondents with >25 EUS-guided drainage/year; n = 21) or years of experience (κ = 0.195 for >10-year experience; n = 33).</p></div><div><h3>Conclusion</h3><p>IOA between endosonographers regarding estimation of debris in WOPN and subsequent stent choice for drainage is poor. The experience of endosonographers did not improve IOA. Studies to standardize the EUS criteria for debris assessment in WOPN and subsequent therapeutic approaches are warranted.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interobserver Agreement on “Assessment of Debris” During Endoscopic Ultrasound-guided Drainage of Walled-off Pancreatic Necrosis\",\"authors\":\"Partha Pal , Sundeep Lakhtakia , Nitin Jagtap , Shujaath Asif , Krithi Krishna Koduri , Rajesh Gupta , Jahangeer Basha , Azimudin Haja , Aniruddha Pratap Singh , Ashirwad Pasumarthy , Zaheer Nabi , Jagdeesh Rampal Singh , Rakesh Kalpala , Mohan Ramchandani , D Nageshwar Reddy\",\"doi\":\"10.1016/j.tige.2023.03.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background and Aims</h3><p>Estimation of the solid component in walled-off pancreatic necrosis<span> (WOPN) during endoscopic ultrasound (EUS) is an important parameter to guide the selection of stent for drainage but is often not objectively quantified.</span></p></div><div><h3>Methods</h3><p>We aimed to study the interobserver agreement (IOA) among endosonographers assessing debris in the pancreatic fluid collection and their choice of stent. EUS videos of 15 patients having pancreatic fluid collection with concurrent magnetic resonance imaging (MRI) assessment of debris were independently reviewed by 40 endosonographers for the percentage of debris (10% increments) and their choice of stent (plastic or metal). The Fleiss kappa (κ) coefficient was used to assess IOA. Post-hoc analysis was done using wider debris intervals (20% or greater increments).</p></div><div><h3>Results</h3><p>Poor agreement was observed for the percentage of debris (κ = 0.188), which did not improve (κ = 0.196) even after including only expert endosonographers with more than 10 years of experience (n = 33). There was fair agreement (κ = 0.266) with reference MRI on the percentage of debris. On post-hoc analysis, the IOA (κ = 0.56, substantial agreement) and agreement with MRI (κ = 0.59, substantial agreement) improved as the debris intervals widened (<10%, 10%-50%, >50%). The agreement for stent selection (plastic vs metal) was poor (κ = 0.174) and did not improve with case volume (κ = 0.153 among respondents with >25 EUS-guided drainage/year; n = 21) or years of experience (κ = 0.195 for >10-year experience; n = 33).</p></div><div><h3>Conclusion</h3><p>IOA between endosonographers regarding estimation of debris in WOPN and subsequent stent choice for drainage is poor. The experience of endosonographers did not improve IOA. Studies to standardize the EUS criteria for debris assessment in WOPN and subsequent therapeutic approaches are warranted.</p></div>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590030723000272\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590030723000272","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Interobserver Agreement on “Assessment of Debris” During Endoscopic Ultrasound-guided Drainage of Walled-off Pancreatic Necrosis
Background and Aims
Estimation of the solid component in walled-off pancreatic necrosis (WOPN) during endoscopic ultrasound (EUS) is an important parameter to guide the selection of stent for drainage but is often not objectively quantified.
Methods
We aimed to study the interobserver agreement (IOA) among endosonographers assessing debris in the pancreatic fluid collection and their choice of stent. EUS videos of 15 patients having pancreatic fluid collection with concurrent magnetic resonance imaging (MRI) assessment of debris were independently reviewed by 40 endosonographers for the percentage of debris (10% increments) and their choice of stent (plastic or metal). The Fleiss kappa (κ) coefficient was used to assess IOA. Post-hoc analysis was done using wider debris intervals (20% or greater increments).
Results
Poor agreement was observed for the percentage of debris (κ = 0.188), which did not improve (κ = 0.196) even after including only expert endosonographers with more than 10 years of experience (n = 33). There was fair agreement (κ = 0.266) with reference MRI on the percentage of debris. On post-hoc analysis, the IOA (κ = 0.56, substantial agreement) and agreement with MRI (κ = 0.59, substantial agreement) improved as the debris intervals widened (<10%, 10%-50%, >50%). The agreement for stent selection (plastic vs metal) was poor (κ = 0.174) and did not improve with case volume (κ = 0.153 among respondents with >25 EUS-guided drainage/year; n = 21) or years of experience (κ = 0.195 for >10-year experience; n = 33).
Conclusion
IOA between endosonographers regarding estimation of debris in WOPN and subsequent stent choice for drainage is poor. The experience of endosonographers did not improve IOA. Studies to standardize the EUS criteria for debris assessment in WOPN and subsequent therapeutic approaches are warranted.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.