{"title":"主动脉残端动脉瘤的分支内移植物修复。","authors":"Sarah E. Langdon BS ,&nbsp;John C. Motta MD ,&nbsp;Alexander Kulik MD, MPH ,&nbsp;Irfan Imami MD ,&nbsp;Lisamarie Kernicky RN, BSN, CCRC ,&nbsp;W. Anthony Lee MD","doi":"10.1016/j.jvsc.2015.05.001","DOIUrl":null,"url":null,"abstract":"<div><p>We present a patient with an aortic stump aneurysm that was repaired with a custom-made, four-branched thoracoabdominal endograft. The repair was performed in two stages using a special delivery system designed to be introduced in an antegrade manner through a median sternotomy due to a lack of iliofemoral access. At 1 year, the patient remains in good health, with his aneurysm completely excluded and decreased in size, without migration, and all branch vessels patent. This report represents a unique endovascular repair of a complex aortic pathology in a patient without other surgical options.</p></div>","PeriodicalId":91348,"journal":{"name":"Journal of vascular surgery cases","volume":"1 2","pages":"Pages 177-179"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jvsc.2015.05.001","citationCount":"0","resultStr":"{\"title\":\"Branched endograft repair of an aortic stump aneurysm\",\"authors\":\"Sarah E. Langdon BS ,&nbsp;John C. Motta MD ,&nbsp;Alexander Kulik MD, MPH ,&nbsp;Irfan Imami MD ,&nbsp;Lisamarie Kernicky RN, BSN, CCRC ,&nbsp;W. Anthony Lee MD\",\"doi\":\"10.1016/j.jvsc.2015.05.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>We present a patient with an aortic stump aneurysm that was repaired with a custom-made, four-branched thoracoabdominal endograft. The repair was performed in two stages using a special delivery system designed to be introduced in an antegrade manner through a median sternotomy due to a lack of iliofemoral access. At 1 year, the patient remains in good health, with his aneurysm completely excluded and decreased in size, without migration, and all branch vessels patent. This report represents a unique endovascular repair of a complex aortic pathology in a patient without other surgical options.</p></div>\",\"PeriodicalId\":91348,\"journal\":{\"name\":\"Journal of vascular surgery cases\",\"volume\":\"1 2\",\"pages\":\"Pages 177-179\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.jvsc.2015.05.001\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of vascular surgery cases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352667X15000776\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of vascular surgery cases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352667X15000776","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们介绍了一名主动脉残端动脉瘤患者,该患者使用定制的四分支胸腹内移植物进行修复。修复分两个阶段进行,使用一种特殊的输送系统,由于缺乏髂股通路,该系统设计为通过正中胸骨切开术顺行引入。1年时,患者健康状况良好,动脉瘤完全排除,体积缩小,无迁移,所有分支血管通畅。本报告介绍了一种在没有其他手术选择的情况下对复杂主动脉病变进行独特的血管内修复的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Branched endograft repair of an aortic stump aneurysm

Branched endograft repair of an aortic stump aneurysm

Branched endograft repair of an aortic stump aneurysm

Branched endograft repair of an aortic stump aneurysm

We present a patient with an aortic stump aneurysm that was repaired with a custom-made, four-branched thoracoabdominal endograft. The repair was performed in two stages using a special delivery system designed to be introduced in an antegrade manner through a median sternotomy due to a lack of iliofemoral access. At 1 year, the patient remains in good health, with his aneurysm completely excluded and decreased in size, without migration, and all branch vessels patent. This report represents a unique endovascular repair of a complex aortic pathology in a patient without other surgical options.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信