WATCHMAN装置部署期间的呼吸暂停管理——附3例病例报告。

IF 1.1 Q3 ANESTHESIOLOGY
Makishi Maeda, Yusuke Yoshikawa, Shunsuke Oura, Kanako Takahashi, Sho Ohno, Naoyuki Hirata, Michiaki Yamakage
{"title":"WATCHMAN装置部署期间的呼吸暂停管理——附3例病例报告。","authors":"Makishi Maeda, Yusuke Yoshikawa, Shunsuke Oura, Kanako Takahashi, Sho Ohno, Naoyuki Hirata, Michiaki Yamakage","doi":"10.4103/aca.aca_11_23","DOIUrl":null,"url":null,"abstract":"<p><p>WATCHMAN is a percutaneous left atrial appendage closure device that is implanted in patients who are unsuitable for anticoagulation therapy for atrial fibrillation. During WATCHMAN implantation, inducing apnea in the patient is preferable to allow stable deployment. We present three cases in which apneic oxygenation was employed to maintain oxygenation during apnea, and oxygen reserve index (ORi<sup>TM</sup>) was measured to evaluate its safety and efficacy. Oxygen was administered continuously via the endotracheal tube during apnea. During all four apneic events in three patients (mean duration of 356 seconds), the ORi values maintained above 0.24, which is generally considered the threshold of partial pressure of arterial oxygen (PaO<sub>2</sub>) > 100 mmHg. Transcutaneous oxygen saturation and PaO<sub>2</sub> remained above 99% and 300 mmHg, respectively. There were no respiratory or circulatory complications during or after the surgery.</p>","PeriodicalId":7997,"journal":{"name":"Annals of Cardiac Anaesthesia","volume":"26 4","pages":"458-460"},"PeriodicalIF":1.1000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691579/pdf/","citationCount":"0","resultStr":"{\"title\":\"Apnea management during WATCHMAN device deployment with apneic oxygenation: A case report of three cases.\",\"authors\":\"Makishi Maeda, Yusuke Yoshikawa, Shunsuke Oura, Kanako Takahashi, Sho Ohno, Naoyuki Hirata, Michiaki Yamakage\",\"doi\":\"10.4103/aca.aca_11_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>WATCHMAN is a percutaneous left atrial appendage closure device that is implanted in patients who are unsuitable for anticoagulation therapy for atrial fibrillation. During WATCHMAN implantation, inducing apnea in the patient is preferable to allow stable deployment. We present three cases in which apneic oxygenation was employed to maintain oxygenation during apnea, and oxygen reserve index (ORi<sup>TM</sup>) was measured to evaluate its safety and efficacy. Oxygen was administered continuously via the endotracheal tube during apnea. During all four apneic events in three patients (mean duration of 356 seconds), the ORi values maintained above 0.24, which is generally considered the threshold of partial pressure of arterial oxygen (PaO<sub>2</sub>) > 100 mmHg. Transcutaneous oxygen saturation and PaO<sub>2</sub> remained above 99% and 300 mmHg, respectively. There were no respiratory or circulatory complications during or after the surgery.</p>\",\"PeriodicalId\":7997,\"journal\":{\"name\":\"Annals of Cardiac Anaesthesia\",\"volume\":\"26 4\",\"pages\":\"458-460\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691579/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Cardiac Anaesthesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/aca.aca_11_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Cardiac Anaesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/aca.aca_11_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

WATCHMAN是一种经皮左心耳闭合装置,用于不适合心房颤动抗凝治疗的患者。WATCHMAN植入期间,最好诱导患者呼吸暂停,以实现稳定部署。我们报告了三例在呼吸暂停期间使用呼吸暂停氧合来维持氧合的病例,并测量了氧储备指数(ORiTM)来评估其安全性和有效性。在呼吸暂停期间,通过气管插管持续给药。在三名患者的所有四次呼吸暂停事件中(平均持续时间356秒),ORi值保持在0.24以上,这通常被认为是动脉氧分压(PaO2)>100 mmHg的阈值。经皮血氧饱和度和PaO2分别保持在99%和300mmHg以上。术中或术后均无呼吸系统或循环系统并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Apnea management during WATCHMAN device deployment with apneic oxygenation: A case report of three cases.

WATCHMAN is a percutaneous left atrial appendage closure device that is implanted in patients who are unsuitable for anticoagulation therapy for atrial fibrillation. During WATCHMAN implantation, inducing apnea in the patient is preferable to allow stable deployment. We present three cases in which apneic oxygenation was employed to maintain oxygenation during apnea, and oxygen reserve index (ORiTM) was measured to evaluate its safety and efficacy. Oxygen was administered continuously via the endotracheal tube during apnea. During all four apneic events in three patients (mean duration of 356 seconds), the ORi values maintained above 0.24, which is generally considered the threshold of partial pressure of arterial oxygen (PaO2) > 100 mmHg. Transcutaneous oxygen saturation and PaO2 remained above 99% and 300 mmHg, respectively. There were no respiratory or circulatory complications during or after the surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.60
自引率
0.00%
发文量
147
审稿时长
26 weeks
期刊介绍: Annals of Cardiac Anaesthesia (ACA) is the official journal of the Indian Association of Cardiovascular Thoracic Anaesthesiologists. The journal is indexed with PubMed/MEDLINE, Excerpta Medica/EMBASE, IndMed and MedInd. The journal’s full text is online at www.annals.in. With the aim of faster and better dissemination of knowledge, we will be publishing articles ‘Ahead of Print’ immediately on acceptance. In addition, the journal would allow free access (Open Access) to its contents, which is likely to attract more readers and citations to articles published in ACA. Authors do not have to pay for submission, processing or publication of articles in ACA.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信