粘结剂的使用方法和热循环对不同粘结剂体系与牙本质粘结性能的影响

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Lamiaa M. Moharam, R. Afifi
{"title":"粘结剂的使用方法和热循环对不同粘结剂体系与牙本质粘结性能的影响","authors":"Lamiaa M. Moharam, R. Afifi","doi":"10.4103/jioh.jioh_235_22","DOIUrl":null,"url":null,"abstract":"Aim: To assess the effect of multiple layers application of different adhesive systems on the microshear bond strength (μSBS) of dentin with and without thermocycling. Materials and Methods: Two hundred forty sound human premolars had their enamel surfaces removed to expose even surfaces of dentin. The teeth were mounted in acrylic resin blocks and then assigned arbitrarily into four main groups (n = 60) representing the investigated adhesives (a self-etch [SE] adhesive, a total-etch [TE] adhesive, and a multimode [MM] adhesive used in TE and SE modes). Individually, the main groups were equally alienated into three subgroups (n = 20), each representing the number of the applied adhesive layers (one layer [1L], two layers [2L], and three layers [3L]). Then, each respective subgroup was divided subsequently into two equal divisions with n = 10 each according to thermocycling (with and without thermocycling). Each occlusal surface received three composite microrods. Prepared specimens were reserved in distilled water at temperature of 37°C until the μSBS test was performed after 24 h or after thermocycling for 3000 cycles at 5°C–55°C water bath. Results: A three-way analysis of variance (ANOVA) disclosed that multilayer application, adhesive type, and thermocycling showed a significant statistical impact on μSBS. The 1L, 2L, and 3L groups showed a statistically significant difference between the groups. The 3L groups showed the highest μSBS, whereas 1L groups recorded the least μSBS. Within the adhesive groups, a statistically significant difference was evident. The highest μSBS was recorded for TE, whereas SE recorded the least μSBS. Thermocycling (TC) has a statistically significant effect on μSBS and “no-thermocycling” (T0) groups recorded higher μSBS than thermocycled groups. Conclusion: Multilayer application of the tested adhesives had the potential to increase dentin μSBS.","PeriodicalId":16138,"journal":{"name":"Journal of International Oral Health","volume":"15 1","pages":"168 - 173"},"PeriodicalIF":0.5000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Influence of adhesive application method and thermocycling on the bonding performance of different adhesive systems to dentin\",\"authors\":\"Lamiaa M. Moharam, R. Afifi\",\"doi\":\"10.4103/jioh.jioh_235_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: To assess the effect of multiple layers application of different adhesive systems on the microshear bond strength (μSBS) of dentin with and without thermocycling. Materials and Methods: Two hundred forty sound human premolars had their enamel surfaces removed to expose even surfaces of dentin. The teeth were mounted in acrylic resin blocks and then assigned arbitrarily into four main groups (n = 60) representing the investigated adhesives (a self-etch [SE] adhesive, a total-etch [TE] adhesive, and a multimode [MM] adhesive used in TE and SE modes). Individually, the main groups were equally alienated into three subgroups (n = 20), each representing the number of the applied adhesive layers (one layer [1L], two layers [2L], and three layers [3L]). Then, each respective subgroup was divided subsequently into two equal divisions with n = 10 each according to thermocycling (with and without thermocycling). Each occlusal surface received three composite microrods. Prepared specimens were reserved in distilled water at temperature of 37°C until the μSBS test was performed after 24 h or after thermocycling for 3000 cycles at 5°C–55°C water bath. Results: A three-way analysis of variance (ANOVA) disclosed that multilayer application, adhesive type, and thermocycling showed a significant statistical impact on μSBS. The 1L, 2L, and 3L groups showed a statistically significant difference between the groups. The 3L groups showed the highest μSBS, whereas 1L groups recorded the least μSBS. Within the adhesive groups, a statistically significant difference was evident. The highest μSBS was recorded for TE, whereas SE recorded the least μSBS. Thermocycling (TC) has a statistically significant effect on μSBS and “no-thermocycling” (T0) groups recorded higher μSBS than thermocycled groups. Conclusion: Multilayer application of the tested adhesives had the potential to increase dentin μSBS.\",\"PeriodicalId\":16138,\"journal\":{\"name\":\"Journal of International Oral Health\",\"volume\":\"15 1\",\"pages\":\"168 - 173\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of International Oral Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jioh.jioh_235_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of International Oral Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jioh.jioh_235_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

目的:评价不同粘接体系的多层应用对有和无热循环的牙本质微剪切结合强度(μSBS)的影响。材料和方法:240颗健康的人类前磨牙去除了牙釉质表面,以暴露出均匀的牙本质表面。将牙齿安装在丙烯酸树脂块中,然后任意分为四个主要组(n=60),代表所研究的粘合剂(自蚀刻[SE]粘合剂、全蚀刻[TE]粘合剂和用于TE和SE模式的多模[MM]粘合剂)。单独地,主要组被等分为三个亚组(n=20),每个亚组代表所施加的粘合剂层的数量(一层[1L]、两层[2L]和三层[3L])。然后,根据热循环(有和没有热循环),每个相应的亚组随后被划分为两个相等的部分,每个部分n=10。每个咬合表面接收三个复合微棒。将制备好的试样保存在37°C的蒸馏水中,直到24小时后进行μSBS试验 h或在5°C–55°C水浴中热循环3000次后。结果:三元方差分析(ANOVA)显示,多层应用、粘合剂类型和热循环对μSBS有显著的统计影响。1L、2L和3L组之间的差异具有统计学意义。3L组显示最高的μSBS,而1L组记录的μSBS最少。在粘合剂组中,统计学上的显著差异是明显的。TE的μSBS最高,而SE的μSBS最低。热循环(TC)对μSBS有统计学显著影响,“无热循环”(T0)组的μSBS高于热循环组。结论:所制备的胶粘剂具有增加牙本质μSBS的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of adhesive application method and thermocycling on the bonding performance of different adhesive systems to dentin
Aim: To assess the effect of multiple layers application of different adhesive systems on the microshear bond strength (μSBS) of dentin with and without thermocycling. Materials and Methods: Two hundred forty sound human premolars had their enamel surfaces removed to expose even surfaces of dentin. The teeth were mounted in acrylic resin blocks and then assigned arbitrarily into four main groups (n = 60) representing the investigated adhesives (a self-etch [SE] adhesive, a total-etch [TE] adhesive, and a multimode [MM] adhesive used in TE and SE modes). Individually, the main groups were equally alienated into three subgroups (n = 20), each representing the number of the applied adhesive layers (one layer [1L], two layers [2L], and three layers [3L]). Then, each respective subgroup was divided subsequently into two equal divisions with n = 10 each according to thermocycling (with and without thermocycling). Each occlusal surface received three composite microrods. Prepared specimens were reserved in distilled water at temperature of 37°C until the μSBS test was performed after 24 h or after thermocycling for 3000 cycles at 5°C–55°C water bath. Results: A three-way analysis of variance (ANOVA) disclosed that multilayer application, adhesive type, and thermocycling showed a significant statistical impact on μSBS. The 1L, 2L, and 3L groups showed a statistically significant difference between the groups. The 3L groups showed the highest μSBS, whereas 1L groups recorded the least μSBS. Within the adhesive groups, a statistically significant difference was evident. The highest μSBS was recorded for TE, whereas SE recorded the least μSBS. Thermocycling (TC) has a statistically significant effect on μSBS and “no-thermocycling” (T0) groups recorded higher μSBS than thermocycled groups. Conclusion: Multilayer application of the tested adhesives had the potential to increase dentin μSBS.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of International Oral Health
Journal of International Oral Health Dentistry-Dentistry (all)
CiteScore
1.00
自引率
14.30%
发文量
15
期刊介绍: It is a journal aimed for research, scientific facts and details covering all specialties of dentistry with a good determination for exploring and sharing the knowledge in the medical and dental fraternity. The scope is therefore huge covering almost all streams of dentistry - starting from original studies, systematic reviews, narrative reviews, very unique case reports. Our journal appreciates research articles pertaining with advancement of dentistry. Journal scope is not limited to these subjects and is more wider covering all specialities of dentistry follows: Preventive and Community Dentistry (Dental Public Health) Endodontics Oral and Maxillofacial Pathology Oral and Maxillofacial Radiology Oral and Maxillofacial Surgery (also called Oral Surgery) Orthodontics and Dentofacial Orthopaedics Periodontology (also called Periodontics) Pediatric Dentistry (also called Pedodontics) Prosthodontics (also called Prosthetic Dentistry) Oral Medicine Special Needs Dentistry (also called Special Care Dentistry) Oral Biology Forensic Odontology Geriatric Dentistry or Geriodontics Implantology Laser and Aesthetic Dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信