掌侧锁定钢板外固定与K线在关节镜辅助桡骨远端关节内骨折内固定中的比较

Uldis Krustiņš, J. Krustiņš, Diāna Bringina, Kristine Laurane, A. Jumtins
{"title":"掌侧锁定钢板外固定与K线在关节镜辅助桡骨远端关节内骨折内固定中的比较","authors":"Uldis Krustiņš, J. Krustiņš, Diāna Bringina, Kristine Laurane, A. Jumtins","doi":"10.1177/1753193419879567","DOIUrl":null,"url":null,"abstract":"This article presents the results of a prospective cohort study that included 63 patients with intra-articular (AO Type C) distal radial fractures who were treated using an arthroscopically assisted approach with either volar locking plates or external fixator and K-wires. Postoperative analysis was carried out using X-ray assessment, clinical data, Patient-Rated Wrist Evaluation score, Gartland and Werley score, Modern Activity Subjective Survey of 2007 score, range of motion, grip, pinch and tripod pinch assessment at 1, 3, 6 and 12 months postoperatively. Despite the statistically significant differences found in a number of parameters during the period of observation, there were no clinically relevant differences determined between the two methods. There was a greater number of complications in the external fixator and K-wire treated patients. Level of evidence: II","PeriodicalId":73762,"journal":{"name":"Journal of hand surgery (Edinburgh, Scotland)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1753193419879567","citationCount":"6","resultStr":"{\"title\":\"Comparison of volar locking plates with external fixation and K-wires in arthroscopically assisted intra-articular distal radial fracture fixation\",\"authors\":\"Uldis Krustiņš, J. Krustiņš, Diāna Bringina, Kristine Laurane, A. Jumtins\",\"doi\":\"10.1177/1753193419879567\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article presents the results of a prospective cohort study that included 63 patients with intra-articular (AO Type C) distal radial fractures who were treated using an arthroscopically assisted approach with either volar locking plates or external fixator and K-wires. Postoperative analysis was carried out using X-ray assessment, clinical data, Patient-Rated Wrist Evaluation score, Gartland and Werley score, Modern Activity Subjective Survey of 2007 score, range of motion, grip, pinch and tripod pinch assessment at 1, 3, 6 and 12 months postoperatively. Despite the statistically significant differences found in a number of parameters during the period of observation, there were no clinically relevant differences determined between the two methods. There was a greater number of complications in the external fixator and K-wire treated patients. Level of evidence: II\",\"PeriodicalId\":73762,\"journal\":{\"name\":\"Journal of hand surgery (Edinburgh, Scotland)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1753193419879567\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of hand surgery (Edinburgh, Scotland)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1753193419879567\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of hand surgery (Edinburgh, Scotland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1753193419879567","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

这篇文章介绍了一项前瞻性队列研究的结果,该研究包括63名关节内(AO C型)桡骨远端骨折患者,他们使用关节镜辅助方法,使用掌侧锁定板或外固定器和K线进行治疗。术后分析使用X射线评估、临床数据、患者评分腕关节评估评分、Gartland和Werley评分、2007年现代活动主观调查评分、1、3、6和12岁时的活动范围、握力、握力和三脚架握力评估 术后数月。尽管在观察期间发现许多参数存在统计学上的显著差异,但两种方法之间没有确定临床相关的差异。外固定器和K线治疗的患者有更多的并发症。证据级别:二
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of volar locking plates with external fixation and K-wires in arthroscopically assisted intra-articular distal radial fracture fixation
This article presents the results of a prospective cohort study that included 63 patients with intra-articular (AO Type C) distal radial fractures who were treated using an arthroscopically assisted approach with either volar locking plates or external fixator and K-wires. Postoperative analysis was carried out using X-ray assessment, clinical data, Patient-Rated Wrist Evaluation score, Gartland and Werley score, Modern Activity Subjective Survey of 2007 score, range of motion, grip, pinch and tripod pinch assessment at 1, 3, 6 and 12 months postoperatively. Despite the statistically significant differences found in a number of parameters during the period of observation, there were no clinically relevant differences determined between the two methods. There was a greater number of complications in the external fixator and K-wire treated patients. Level of evidence: II
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信