打印机水平分辨率对3d打印临时冠真实性影响的体外研究

Q4 Dentistry
Pham Nhu Hai, T. M. Son, Nguyen Viet Anh, V. Ngoc, N. T. Tra
{"title":"打印机水平分辨率对3d打印临时冠真实性影响的体外研究","authors":"Pham Nhu Hai, T. M. Son, Nguyen Viet Anh, V. Ngoc, N. T. Tra","doi":"10.1055/s-0043-1764478","DOIUrl":null,"url":null,"abstract":"Abstract Objectives  Provisional crowns play an integral role in prosthodontic therapy and need to be fabricated with high accuracy to ensure good marginal fit and proper contour. The aim of this study is to evaluate the effect of 3D printer's horizontal pixel resolution on trueness of the intaglio surface, external surface, and marginal area and the actual marginal adaptation of the interim crowns. Materials and Methods  A gypsum reference model of mandible with a prepared right first molar was scanned with a dental laboratory scanner (AutoScan-DS-MIX, Shining 3D) and a digital provisional crown was design using the computer-aided design (CAD) software (Exocad). The provisional crown was manufactured by two printers with different horizontal resolutions (Sonic Mini 4K Printer and Sonic Mini 8K Printer). The printed crowns were scanned using the aforementioned scanner. The trueness of the external surface, internal surface, and marginal area of the provisional crowns was evaluated by comparing the scanned data with the reference CAD design data using a 3D inspection software (Geomagic Control X, 3D systems). The trueness of the crown manufactured by two printers was compared by a two-sided test ( α  = 0.05). Finally, the marginal adaptation of the provisional crowns was evaluated on the printed removable dies and compared. Results  The results revealed that there was a significant difference in the trueness of the marginal area and the marginal adaptation ( p  < 0.05). Conclusions  It can be concluded that the trueness of provisional crown marginal area and the marginal adaptation was affected by the horizontal resolution of the 3D printer.","PeriodicalId":37771,"journal":{"name":"European Journal of General Dentistry","volume":"12 1","pages":"034 - 041"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Effect of Horizontal Resolution of Printer on Trueness of 3D-Printed Provisional Crown: An In Vitro Study\",\"authors\":\"Pham Nhu Hai, T. M. Son, Nguyen Viet Anh, V. Ngoc, N. T. Tra\",\"doi\":\"10.1055/s-0043-1764478\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Objectives  Provisional crowns play an integral role in prosthodontic therapy and need to be fabricated with high accuracy to ensure good marginal fit and proper contour. The aim of this study is to evaluate the effect of 3D printer's horizontal pixel resolution on trueness of the intaglio surface, external surface, and marginal area and the actual marginal adaptation of the interim crowns. Materials and Methods  A gypsum reference model of mandible with a prepared right first molar was scanned with a dental laboratory scanner (AutoScan-DS-MIX, Shining 3D) and a digital provisional crown was design using the computer-aided design (CAD) software (Exocad). The provisional crown was manufactured by two printers with different horizontal resolutions (Sonic Mini 4K Printer and Sonic Mini 8K Printer). The printed crowns were scanned using the aforementioned scanner. The trueness of the external surface, internal surface, and marginal area of the provisional crowns was evaluated by comparing the scanned data with the reference CAD design data using a 3D inspection software (Geomagic Control X, 3D systems). The trueness of the crown manufactured by two printers was compared by a two-sided test ( α  = 0.05). Finally, the marginal adaptation of the provisional crowns was evaluated on the printed removable dies and compared. Results  The results revealed that there was a significant difference in the trueness of the marginal area and the marginal adaptation ( p  < 0.05). Conclusions  It can be concluded that the trueness of provisional crown marginal area and the marginal adaptation was affected by the horizontal resolution of the 3D printer.\",\"PeriodicalId\":37771,\"journal\":{\"name\":\"European Journal of General Dentistry\",\"volume\":\"12 1\",\"pages\":\"034 - 041\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of General Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0043-1764478\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of General Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1764478","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 2

摘要

抽象目标 临时牙冠在口腔修复治疗中起着不可或缺的作用,需要高精度制造,以确保良好的边缘配合和合适的轮廓。本研究的目的是评估3D打印机的水平像素分辨率对凹版表面、外表面和边缘区域的真实性以及过渡牙冠的实际边缘适应的影响。材料和方法 用牙科实验室扫描仪(AutoScan DS MIX,Shining 3D)扫描具有制备的右第一磨牙的下颌骨石膏参考模型,并使用计算机辅助设计(CAD)软件(Exocad)设计数字临时牙冠。临时牙冠由两台具有不同水平分辨率的打印机(Sonic Mini 4K打印机和Sonic Mini 8K打印机)制造。使用上述扫描仪对印刷的牙冠进行扫描。通过使用3D检查软件(Geomagic Control X,3D系统)将扫描数据与参考CAD设计数据进行比较,来评估临时牙冠的外表面、内表面和边缘区域的真实性。通过双面测试比较了两台打印机制造的牙冠的真实性(α = 0.05)。最后,在印刷的可移除模具上评估临时牙冠的边缘适应性并进行比较。后果 结果表明,边缘区域的真实性和边缘适应性存在显著差异(p < 0.05)。结论 可以得出结论,3D打印机的水平分辨率影响了临时牙冠边缘区域的真实性和边缘适应性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Horizontal Resolution of Printer on Trueness of 3D-Printed Provisional Crown: An In Vitro Study
Abstract Objectives  Provisional crowns play an integral role in prosthodontic therapy and need to be fabricated with high accuracy to ensure good marginal fit and proper contour. The aim of this study is to evaluate the effect of 3D printer's horizontal pixel resolution on trueness of the intaglio surface, external surface, and marginal area and the actual marginal adaptation of the interim crowns. Materials and Methods  A gypsum reference model of mandible with a prepared right first molar was scanned with a dental laboratory scanner (AutoScan-DS-MIX, Shining 3D) and a digital provisional crown was design using the computer-aided design (CAD) software (Exocad). The provisional crown was manufactured by two printers with different horizontal resolutions (Sonic Mini 4K Printer and Sonic Mini 8K Printer). The printed crowns were scanned using the aforementioned scanner. The trueness of the external surface, internal surface, and marginal area of the provisional crowns was evaluated by comparing the scanned data with the reference CAD design data using a 3D inspection software (Geomagic Control X, 3D systems). The trueness of the crown manufactured by two printers was compared by a two-sided test ( α  = 0.05). Finally, the marginal adaptation of the provisional crowns was evaluated on the printed removable dies and compared. Results  The results revealed that there was a significant difference in the trueness of the marginal area and the marginal adaptation ( p  < 0.05). Conclusions  It can be concluded that the trueness of provisional crown marginal area and the marginal adaptation was affected by the horizontal resolution of the 3D printer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of General Dentistry
European Journal of General Dentistry Dentistry-Dentistry (all)
CiteScore
1.00
自引率
0.00%
发文量
21
期刊介绍: European Journal of General Dentistry (EJGD) is one of the leading open-access international dental journal within the field of Dentistry. The aim of EJGD is publishing novel and high-quality research papers, as well as to influence the practice of dentistry at clinician, research, industry and policy-maker level on an international basis. EJGD publishes articles on all disciplines of dentistry including the cariology, orthodontics, oral surgery, preventive dentistry, periodontology, endodontology, operative dentistry, fixed and removable prosthodontics, dental biomaterials science, long-term clinical trials including epidemiology and oral health, technology transfer of new scientific instrumentation or procedures, as well as clinically relevant oral biology and translational research.Moreover, EJGD also publish the scientific researches evaluating the use of new biomaterials, new drugs and new methods for treatment of patients with different kinds of oral and maxillofacial diseases or defects, the diagnosis of oral and maxillofacial diseases with new methods, etc. Moreover, researches on the quality of life, psychological interventions, improving disease treatment outcomes, the prevention, diagnosis and management of cancer therapeutic complications, rehabilitation, palliative and end of life care, and support teamwork for cancer care and oral health care for old patients are also welcome. EJGD publishes research articles, case reports, reviews and comparison studies evaluating materials and methods in the all fields of related to dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信