中压架空电力线路用保护绝缘电线:优点和计算

Q3 Energy
O. D. Podoltsev, I. Kucheriava
{"title":"中压架空电力线路用保护绝缘电线:优点和计算","authors":"O. D. Podoltsev, I. Kucheriava","doi":"10.15407/techned2022.05.014","DOIUrl":null,"url":null,"abstract":"The paper presents the advantages of protected insulated wires for medium-voltage (up to 35 kV) overhead power lines compared to the lines with traditional non-insulated wires. The mathematical model is developed and the computer calculations are realized for a 20 kV protected insulated wire with a steel-aluminum core. For such design, the distributions of the magnetic field and current density in three wires of overhead power line are analyzed, their resistance is determined taking into account the nonlinear properties of the steel core within the frequency range of 50–10000 Hz. This makes it possible to compute the electrical losses in the conductors of the power lines under the transient conditions and at high harmonics in the power network. References 8, figures 4.","PeriodicalId":38557,"journal":{"name":"Technical Electrodynamics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PROTECTED INSULATED WIRES FOR MEDIUM-VOLTAGE OVERHEAD POWER LINES: ADVANTAGES, COMPUTATIONS\",\"authors\":\"O. D. Podoltsev, I. Kucheriava\",\"doi\":\"10.15407/techned2022.05.014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents the advantages of protected insulated wires for medium-voltage (up to 35 kV) overhead power lines compared to the lines with traditional non-insulated wires. The mathematical model is developed and the computer calculations are realized for a 20 kV protected insulated wire with a steel-aluminum core. For such design, the distributions of the magnetic field and current density in three wires of overhead power line are analyzed, their resistance is determined taking into account the nonlinear properties of the steel core within the frequency range of 50–10000 Hz. This makes it possible to compute the electrical losses in the conductors of the power lines under the transient conditions and at high harmonics in the power network. References 8, figures 4.\",\"PeriodicalId\":38557,\"journal\":{\"name\":\"Technical Electrodynamics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technical Electrodynamics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15407/techned2022.05.014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical Electrodynamics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15407/techned2022.05.014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了中压(高达35 kV)架空电力线路用保护绝缘电线与传统非绝缘电线相比的优点。建立了钢铝芯20kV保护绝缘导线的数学模型,并进行了计算机计算。在这种设计中,分析了架空电力线三根导线中的磁场和电流密度的分布,并考虑到钢芯在50–10000 Hz频率范围内的非线性特性来确定它们的电阻。这使得可以计算在瞬态条件下以及在电网中的高次谐波下电力线的导体中的电损耗。参考文献8,图4。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PROTECTED INSULATED WIRES FOR MEDIUM-VOLTAGE OVERHEAD POWER LINES: ADVANTAGES, COMPUTATIONS
The paper presents the advantages of protected insulated wires for medium-voltage (up to 35 kV) overhead power lines compared to the lines with traditional non-insulated wires. The mathematical model is developed and the computer calculations are realized for a 20 kV protected insulated wire with a steel-aluminum core. For such design, the distributions of the magnetic field and current density in three wires of overhead power line are analyzed, their resistance is determined taking into account the nonlinear properties of the steel core within the frequency range of 50–10000 Hz. This makes it possible to compute the electrical losses in the conductors of the power lines under the transient conditions and at high harmonics in the power network. References 8, figures 4.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Technical Electrodynamics
Technical Electrodynamics Energy-Energy Engineering and Power Technology
CiteScore
1.80
自引率
0.00%
发文量
72
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信