人工瓣膜血栓形成:文献综述和两例报告

IF 0.2 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
Cor et vasa Pub Date : 2023-03-01 DOI:10.33678/cor.2022.054
Kotryna Druteikaitė, Simona Bėrontaitė, Gintarė Valterytė, G. Jaruševičius
{"title":"人工瓣膜血栓形成:文献综述和两例报告","authors":"Kotryna Druteikaitė, Simona Bėrontaitė, Gintarė Valterytė, G. Jaruševičius","doi":"10.33678/cor.2022.054","DOIUrl":null,"url":null,"abstract":"Prosthetic heart valve thrombosis is one of the most dangerous prosthetic valve complications. Proper monitoring and management of these patients help to prevent this complication. Fluoroscopy is advantageous in cases of thrombosis to assess the function of the prosthetic valve by measuring opening and closing angles. We describe two cases of aortic mechanical valve thrombosis with different mechanisms of thrombus formation. The fi rst case was a 48-year-old woman admitted to the hospital because of shortness of breath during minimal exertion and signifi cantly reduced exercise tolerance. Due to rheumatic heart disease the patient underwent aortic and mitral mechanical prosthesis and has been using warfarin in therapeutic norms. During echocardioscopy aortic prosthesis obstruction and severe tricuspid valve regurgitation were observed. The patient was scheduled for aortic root and TV prosthesis surgery. The second patient also had aortic mechanical valve due to severe aortic stenosis caused by rheumatism and presented with organizing pneumonia and progressing respiratory failure as complications of the COVID-19 infection and was admitted with dyspnea, cough, and weakness. Aortic prosthetic valve thrombosis was diagnosed despite optimal treatment and therapeutic INR.","PeriodicalId":10787,"journal":{"name":"Cor et vasa","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prosthetic valve thrombosis: literature review and two case reports\",\"authors\":\"Kotryna Druteikaitė, Simona Bėrontaitė, Gintarė Valterytė, G. Jaruševičius\",\"doi\":\"10.33678/cor.2022.054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Prosthetic heart valve thrombosis is one of the most dangerous prosthetic valve complications. Proper monitoring and management of these patients help to prevent this complication. Fluoroscopy is advantageous in cases of thrombosis to assess the function of the prosthetic valve by measuring opening and closing angles. We describe two cases of aortic mechanical valve thrombosis with different mechanisms of thrombus formation. The fi rst case was a 48-year-old woman admitted to the hospital because of shortness of breath during minimal exertion and signifi cantly reduced exercise tolerance. Due to rheumatic heart disease the patient underwent aortic and mitral mechanical prosthesis and has been using warfarin in therapeutic norms. During echocardioscopy aortic prosthesis obstruction and severe tricuspid valve regurgitation were observed. The patient was scheduled for aortic root and TV prosthesis surgery. The second patient also had aortic mechanical valve due to severe aortic stenosis caused by rheumatism and presented with organizing pneumonia and progressing respiratory failure as complications of the COVID-19 infection and was admitted with dyspnea, cough, and weakness. Aortic prosthetic valve thrombosis was diagnosed despite optimal treatment and therapeutic INR.\",\"PeriodicalId\":10787,\"journal\":{\"name\":\"Cor et vasa\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cor et vasa\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33678/cor.2022.054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cor et vasa","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33678/cor.2022.054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

人工心脏瓣膜血栓形成是最危险的人工瓣膜并发症之一。对这些患者进行适当的监测和管理有助于预防这种并发症。在血栓形成的情况下,荧光镜检查有利于通过测量打开和关闭角度来评估人工瓣膜的功能。我们描述了两例主动脉机械瓣膜血栓形成的不同血栓形成机制。第一个病例是一名48岁的女性,她因在最小运动量下呼吸急促和运动耐受性显著降低而入院。由于风湿性心脏病,患者接受了主动脉和二尖瓣机械假体,并在治疗规范中使用华法林。在超声心动图检查中,观察到主动脉瓣阻塞和严重的三尖瓣反流。患者被安排进行主动脉根部和电视假体手术。第二名患者也因风湿引起的严重主动脉狭窄而患有主动脉机械瓣,并表现为组织性肺炎和进展性呼吸衰竭,这是新冠肺炎感染的并发症,并因呼吸困难、咳嗽和虚弱入院。尽管采用了最佳治疗和INR治疗,但仍诊断出主动脉瓣血栓形成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Prosthetic valve thrombosis: literature review and two case reports
Prosthetic heart valve thrombosis is one of the most dangerous prosthetic valve complications. Proper monitoring and management of these patients help to prevent this complication. Fluoroscopy is advantageous in cases of thrombosis to assess the function of the prosthetic valve by measuring opening and closing angles. We describe two cases of aortic mechanical valve thrombosis with different mechanisms of thrombus formation. The fi rst case was a 48-year-old woman admitted to the hospital because of shortness of breath during minimal exertion and signifi cantly reduced exercise tolerance. Due to rheumatic heart disease the patient underwent aortic and mitral mechanical prosthesis and has been using warfarin in therapeutic norms. During echocardioscopy aortic prosthesis obstruction and severe tricuspid valve regurgitation were observed. The patient was scheduled for aortic root and TV prosthesis surgery. The second patient also had aortic mechanical valve due to severe aortic stenosis caused by rheumatism and presented with organizing pneumonia and progressing respiratory failure as complications of the COVID-19 infection and was admitted with dyspnea, cough, and weakness. Aortic prosthetic valve thrombosis was diagnosed despite optimal treatment and therapeutic INR.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cor et vasa
Cor et vasa CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
0.50
自引率
50.00%
发文量
66
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信