基于回收系统的纺织品执行器

IF 1 4区 工程技术 Q3 MATERIALS SCIENCE, TEXTILES
R. Aileni, D. Toma, C. Stroe, T. Sarbu
{"title":"基于回收系统的纺织品执行器","authors":"R. Aileni, D. Toma, C. Stroe, T. Sarbu","doi":"10.35530/it.074.04.2022100","DOIUrl":null,"url":null,"abstract":"This paper presents a medical recovery system based on electrical stimuli transmitted through textile electrodes based\non copper microparticles. The textile electrodes are connected to an electronic device capable of generating\ntranscutaneous electrical nerve stimulation (TENS) using low-frequency (0–100 Hz) (diadynamic or interference)\nelectrical currents. To evaluate the system, the current intensity, frequency and supply voltage were measured using\ndifferent multimeters (Agilent Technologies U3606A and portable digital multimeter), and the signal was analysed.\nDepending on the intensity of the transcutaneous electrostimulation program, obtained by varying the electrical\nparameters, such as electrical voltage (U, mV), current intensity (I, mA) and frequency (f, Hz), it is possible that the\npatient feels pinches or vibration.","PeriodicalId":13638,"journal":{"name":"Industria Textila","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2023-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Recovery system-based textile actuators\",\"authors\":\"R. Aileni, D. Toma, C. Stroe, T. Sarbu\",\"doi\":\"10.35530/it.074.04.2022100\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a medical recovery system based on electrical stimuli transmitted through textile electrodes based\\non copper microparticles. The textile electrodes are connected to an electronic device capable of generating\\ntranscutaneous electrical nerve stimulation (TENS) using low-frequency (0–100 Hz) (diadynamic or interference)\\nelectrical currents. To evaluate the system, the current intensity, frequency and supply voltage were measured using\\ndifferent multimeters (Agilent Technologies U3606A and portable digital multimeter), and the signal was analysed.\\nDepending on the intensity of the transcutaneous electrostimulation program, obtained by varying the electrical\\nparameters, such as electrical voltage (U, mV), current intensity (I, mA) and frequency (f, Hz), it is possible that the\\npatient feels pinches or vibration.\",\"PeriodicalId\":13638,\"journal\":{\"name\":\"Industria Textila\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Industria Textila\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.35530/it.074.04.2022100\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, TEXTILES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Industria Textila","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.35530/it.074.04.2022100","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, TEXTILES","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种基于基于铜微粒的纺织电极传输电刺激的医疗恢复系统。纺织品电极连接到能够使用低频(0-100 Hz)(双动态或干扰)电流产生经皮神经电刺激(TENS)的电子设备。为了评估系统,使用不同的万用表(Agilent Technologies U3606A和便携式数字万用表)测量了电流强度、频率和电源电压,并对信号进行了分析。根据经皮电刺激程序的强度,通过改变电参数获得,如电压(U, mV),电流强度(I, mA)和频率(f, Hz),患者可能会感到挤压或振动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Recovery system-based textile actuators
This paper presents a medical recovery system based on electrical stimuli transmitted through textile electrodes based on copper microparticles. The textile electrodes are connected to an electronic device capable of generating transcutaneous electrical nerve stimulation (TENS) using low-frequency (0–100 Hz) (diadynamic or interference) electrical currents. To evaluate the system, the current intensity, frequency and supply voltage were measured using different multimeters (Agilent Technologies U3606A and portable digital multimeter), and the signal was analysed. Depending on the intensity of the transcutaneous electrostimulation program, obtained by varying the electrical parameters, such as electrical voltage (U, mV), current intensity (I, mA) and frequency (f, Hz), it is possible that the patient feels pinches or vibration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Industria Textila
Industria Textila 工程技术-材料科学:纺织
CiteScore
1.80
自引率
14.30%
发文量
81
审稿时长
3.5 months
期刊介绍: Industria Textila journal is addressed to university and research specialists, to companies active in the textiles and clothing sector and to the related sectors users of textile products with a technical purpose.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信