{"title":"水平定向钻井条件下埋地管道涂层完整性和阴极保护评估","authors":"Y. Huo, Bob Varela, M. Tan","doi":"10.1080/1478422X.2022.2120090","DOIUrl":null,"url":null,"abstract":"ABSTRACT A moving electrochemical probe technique is developed for probing coating damages on underground pipelines installed by horizontal directional drilling (HDD) and for assessing the efficiency of cathodic protection (CP) through measuring local polarisation currents and local electrochemical impedance spectroscopy (EIS). The capability and accuracy of the probe in detecting coating defects have been evaluated, and compared with current techniques, using a simulated HDD pipe in a borehole. Results show that the probe is able to detect the locations of coating defects over the HDD pipe and that the capacitance of coating defects calculated from EIS data is a rather accurate parameter for defect size determination. The probe has also been used to apply local CP over coating defects for enhancing local corrosion protection. Preliminary field testing on a section of simulated HDD pipe has also shown reasonable accuracy of the probe in determining coating defect locations and sizes.","PeriodicalId":10711,"journal":{"name":"Corrosion Engineering, Science and Technology","volume":"57 1","pages":"717 - 729"},"PeriodicalIF":1.5000,"publicationDate":"2022-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessing coating integrity and cathodic protection on buried pipelines under horizontal directional drilling conditions\",\"authors\":\"Y. Huo, Bob Varela, M. Tan\",\"doi\":\"10.1080/1478422X.2022.2120090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT A moving electrochemical probe technique is developed for probing coating damages on underground pipelines installed by horizontal directional drilling (HDD) and for assessing the efficiency of cathodic protection (CP) through measuring local polarisation currents and local electrochemical impedance spectroscopy (EIS). The capability and accuracy of the probe in detecting coating defects have been evaluated, and compared with current techniques, using a simulated HDD pipe in a borehole. Results show that the probe is able to detect the locations of coating defects over the HDD pipe and that the capacitance of coating defects calculated from EIS data is a rather accurate parameter for defect size determination. The probe has also been used to apply local CP over coating defects for enhancing local corrosion protection. Preliminary field testing on a section of simulated HDD pipe has also shown reasonable accuracy of the probe in determining coating defect locations and sizes.\",\"PeriodicalId\":10711,\"journal\":{\"name\":\"Corrosion Engineering, Science and Technology\",\"volume\":\"57 1\",\"pages\":\"717 - 729\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2022-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Corrosion Engineering, Science and Technology\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1080/1478422X.2022.2120090\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion Engineering, Science and Technology","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1080/1478422X.2022.2120090","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
Assessing coating integrity and cathodic protection on buried pipelines under horizontal directional drilling conditions
ABSTRACT A moving electrochemical probe technique is developed for probing coating damages on underground pipelines installed by horizontal directional drilling (HDD) and for assessing the efficiency of cathodic protection (CP) through measuring local polarisation currents and local electrochemical impedance spectroscopy (EIS). The capability and accuracy of the probe in detecting coating defects have been evaluated, and compared with current techniques, using a simulated HDD pipe in a borehole. Results show that the probe is able to detect the locations of coating defects over the HDD pipe and that the capacitance of coating defects calculated from EIS data is a rather accurate parameter for defect size determination. The probe has also been used to apply local CP over coating defects for enhancing local corrosion protection. Preliminary field testing on a section of simulated HDD pipe has also shown reasonable accuracy of the probe in determining coating defect locations and sizes.
期刊介绍:
Corrosion Engineering, Science and Technology provides broad international coverage of research and practice in corrosion processes and corrosion control. Peer-reviewed contributions address all aspects of corrosion engineering and corrosion science; there is strong emphasis on effective design and materials selection to combat corrosion and the journal carries failure case studies to further knowledge in these areas.