Andreas Greiner, O. Böckmann, S. Weber, M. Ostermann, M. Schaefer
{"title":"CoolSkin","authors":"Andreas Greiner, O. Böckmann, S. Weber, M. Ostermann, M. Schaefer","doi":"10.47982/jfde.2022.powerskin.3","DOIUrl":null,"url":null,"abstract":"The article investigates the dependencies of façade design and construction in the integration of a sustainable solar-powered cooling system based on closed adsorption. The presented work focuses on the possible design variants of the envelope surface of the façade -integrated adsorber. The principle of adsorption cooling is presented and, based on this, architectural options for façade integration are investigated. This is done both constructively and visually. For each variant, the solar gains are summed up and compared with each other. A functionally designed adsorber, similar to a flat plate collector, serves as a reference and starting point for the modifications. It provides the comparative value for the energy evaluation. The modification is limited to the visible surface of the absorber. The texture of the solar adsorbing sheet was changed and the glazing used was replaced by ETFE cushions and by a novel ETFE vacuum panel. Finally, the solar simulation results were integrated into the higher-level system simulation to evaluate the resulting gain in cooling capacity. The results show that the system could generate more than 100 W per installed square metre of adsorber façade. Furthermore, higher solar gains compared to the reference case can be obtained at particular times of the day due to geometry and material changes. However, the modifications always lead to a reduction of the total cooling power. In conclusion, the simulation results reveal that design flexibility is possible, but currently the studied design variants have a lower cooling capacity compared to the solely functionally designed adsorber.","PeriodicalId":37451,"journal":{"name":"Journal of Facade Design and Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CoolSkin\",\"authors\":\"Andreas Greiner, O. Böckmann, S. Weber, M. Ostermann, M. Schaefer\",\"doi\":\"10.47982/jfde.2022.powerskin.3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article investigates the dependencies of façade design and construction in the integration of a sustainable solar-powered cooling system based on closed adsorption. The presented work focuses on the possible design variants of the envelope surface of the façade -integrated adsorber. The principle of adsorption cooling is presented and, based on this, architectural options for façade integration are investigated. This is done both constructively and visually. For each variant, the solar gains are summed up and compared with each other. A functionally designed adsorber, similar to a flat plate collector, serves as a reference and starting point for the modifications. It provides the comparative value for the energy evaluation. The modification is limited to the visible surface of the absorber. The texture of the solar adsorbing sheet was changed and the glazing used was replaced by ETFE cushions and by a novel ETFE vacuum panel. Finally, the solar simulation results were integrated into the higher-level system simulation to evaluate the resulting gain in cooling capacity. The results show that the system could generate more than 100 W per installed square metre of adsorber façade. Furthermore, higher solar gains compared to the reference case can be obtained at particular times of the day due to geometry and material changes. However, the modifications always lead to a reduction of the total cooling power. In conclusion, the simulation results reveal that design flexibility is possible, but currently the studied design variants have a lower cooling capacity compared to the solely functionally designed adsorber.\",\"PeriodicalId\":37451,\"journal\":{\"name\":\"Journal of Facade Design and Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Facade Design and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47982/jfde.2022.powerskin.3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Facade Design and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47982/jfde.2022.powerskin.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
The article investigates the dependencies of façade design and construction in the integration of a sustainable solar-powered cooling system based on closed adsorption. The presented work focuses on the possible design variants of the envelope surface of the façade -integrated adsorber. The principle of adsorption cooling is presented and, based on this, architectural options for façade integration are investigated. This is done both constructively and visually. For each variant, the solar gains are summed up and compared with each other. A functionally designed adsorber, similar to a flat plate collector, serves as a reference and starting point for the modifications. It provides the comparative value for the energy evaluation. The modification is limited to the visible surface of the absorber. The texture of the solar adsorbing sheet was changed and the glazing used was replaced by ETFE cushions and by a novel ETFE vacuum panel. Finally, the solar simulation results were integrated into the higher-level system simulation to evaluate the resulting gain in cooling capacity. The results show that the system could generate more than 100 W per installed square metre of adsorber façade. Furthermore, higher solar gains compared to the reference case can be obtained at particular times of the day due to geometry and material changes. However, the modifications always lead to a reduction of the total cooling power. In conclusion, the simulation results reveal that design flexibility is possible, but currently the studied design variants have a lower cooling capacity compared to the solely functionally designed adsorber.
期刊介绍:
The Journal of Facade Design and Engineering presents new research results and new proven practice in the field of facade design and engineering. The goal is to improve building technologies, as well as process management and architectural design. This journal is a valuable resource for professionals and academics involved in the design and engineering of building envelopes, including the following disciplines: Architecture Façade Engineering Climate Design Building Services Integration Building Physics Façade Design and Construction Management Novel Material Applications. The journal will be directed at the scientific community, but it will also feature papers that focus on the dissemination of science into practice and industrial innovations. In this way, readers explore the interaction between scientific developments, technical considerations and management issues.