{"title":"应用耦合器微吻合器切除端到端吻合治疗小脑后下动脉远端动脉瘤1例","authors":"O. Goren, R. Sampath, Akshal S. Patel, C. Griessenauer, C. Schirmer, D. Newell","doi":"10.1093/neuopn/okaa002","DOIUrl":null,"url":null,"abstract":"\n \n \n The Coupler microanastomotic device (Medical Companies Alliance, Birmingham, Alabama) aims at facilitating safe and efficient end-to-end reconstruction of the native vessel ends following resection of intracranial aneurysms.\n \n \n \n We report the first case of the Coupler device used to treat a ruptured posterior inferior cerebellar artery (PICA) aneurysm. Following aneurysmal trapping and excision, the native parent vessel ends were connected in an end-to-end fashion.\n \n \n \n The microanastomotic Coupler device is an acceptable option for end-to-end anastomosis and was successfully applied in the management of a ruptured fusiform PICA aneurysm.\n","PeriodicalId":93342,"journal":{"name":"Neurosurgery open","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1093/neuopn/okaa002","citationCount":"0","resultStr":"{\"title\":\"Use of the Coupler Microanastomotic Device for the Treatment of a Distal Posterior Inferior Cerebellar Artery Aneurysm Via Excision and End-to-End Anastomosis—A Case Report\",\"authors\":\"O. Goren, R. Sampath, Akshal S. Patel, C. Griessenauer, C. Schirmer, D. Newell\",\"doi\":\"10.1093/neuopn/okaa002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n \\n \\n The Coupler microanastomotic device (Medical Companies Alliance, Birmingham, Alabama) aims at facilitating safe and efficient end-to-end reconstruction of the native vessel ends following resection of intracranial aneurysms.\\n \\n \\n \\n We report the first case of the Coupler device used to treat a ruptured posterior inferior cerebellar artery (PICA) aneurysm. Following aneurysmal trapping and excision, the native parent vessel ends were connected in an end-to-end fashion.\\n \\n \\n \\n The microanastomotic Coupler device is an acceptable option for end-to-end anastomosis and was successfully applied in the management of a ruptured fusiform PICA aneurysm.\\n\",\"PeriodicalId\":93342,\"journal\":{\"name\":\"Neurosurgery open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1093/neuopn/okaa002\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurosurgery open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/neuopn/okaa002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurosurgery open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/neuopn/okaa002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Coupler微型吻合装置(Medical Companies Alliance,Birmingham,Alabama)旨在促进颅内动脉瘤切除后天然血管端部的安全高效端到端重建。我们报告了第一例使用Coupler装置治疗小脑后下动脉(PICA)动脉瘤破裂的病例。动脉瘤捕获和切除后,天然母血管末端以端到端的方式连接。显微吻合耦合器是端对端吻合的一种可接受的选择,并成功应用于治疗破裂的梭形PICA动脉瘤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Use of the Coupler Microanastomotic Device for the Treatment of a Distal Posterior Inferior Cerebellar Artery Aneurysm Via Excision and End-to-End Anastomosis—A Case Report
The Coupler microanastomotic device (Medical Companies Alliance, Birmingham, Alabama) aims at facilitating safe and efficient end-to-end reconstruction of the native vessel ends following resection of intracranial aneurysms. We report the first case of the Coupler device used to treat a ruptured posterior inferior cerebellar artery (PICA) aneurysm. Following aneurysmal trapping and excision, the native parent vessel ends were connected in an end-to-end fashion. The microanastomotic Coupler device is an acceptable option for end-to-end anastomosis and was successfully applied in the management of a ruptured fusiform PICA aneurysm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信