M. Badeche, Y. Bouchahm
{"title":"半干旱气候下大型玻璃办公建筑室内环境研究","authors":"M. Badeche, Y. Bouchahm","doi":"10.5755/j01.sace.29.2.28008","DOIUrl":null,"url":null,"abstract":"In recent years the rate of buildings with large glazed facades is rapidly increasing, particularly in office buildings. Where, the creation of a suitable thermal and visual comfort is a significant factor affecting productivity. The use of large glazed facades without adapted shading measure generates thermal and visual discomfort, wich ranges from uncomfortable environment conditions to serious health effects. Specialized work and literature about performance evaluation of large glazed office buildings in relation to their environment are lacking in semi arid climates, characterized by significant intensity of solar radiations in the summer period of the year.\nThis study investigates the impact of large glazing areas on thermal and visual comfort in a sample of naturally ventilated office building located in the semi arid climate of Algeria (36°, 17 N and 7°, 23’ E). A Post Occupancy Evaluation technique (POE), being a mainstream activity in the process of building operation phase is used for this purpose. The main objective is to stress practitioners, specifically architects, to take conscious decisions in an early phase of design process. The study clearly highlighted discomfort in the studied office building. It included unacceptable temperature arising from glazed facade; overheating due to excessive solar gains; insufficient ventilation and poor daylighting. The results indicate that such large fenestration system is not recommended in summer time. However, a judicious choice of the glazing size and type by simulation tools must balance lighting and thermal needs.","PeriodicalId":36795,"journal":{"name":"Journal of Sustainable Architecture and Civil Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A study of Indoor Environment of Large Glazed Office Building in Semi Arid Climate\",\"authors\":\"M. Badeche, Y. Bouchahm\",\"doi\":\"10.5755/j01.sace.29.2.28008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years the rate of buildings with large glazed facades is rapidly increasing, particularly in office buildings. Where, the creation of a suitable thermal and visual comfort is a significant factor affecting productivity. The use of large glazed facades without adapted shading measure generates thermal and visual discomfort, wich ranges from uncomfortable environment conditions to serious health effects. Specialized work and literature about performance evaluation of large glazed office buildings in relation to their environment are lacking in semi arid climates, characterized by significant intensity of solar radiations in the summer period of the year.\\nThis study investigates the impact of large glazing areas on thermal and visual comfort in a sample of naturally ventilated office building located in the semi arid climate of Algeria (36°, 17 N and 7°, 23’ E). A Post Occupancy Evaluation technique (POE), being a mainstream activity in the process of building operation phase is used for this purpose. The main objective is to stress practitioners, specifically architects, to take conscious decisions in an early phase of design process. The study clearly highlighted discomfort in the studied office building. It included unacceptable temperature arising from glazed facade; overheating due to excessive solar gains; insufficient ventilation and poor daylighting. The results indicate that such large fenestration system is not recommended in summer time. However, a judicious choice of the glazing size and type by simulation tools must balance lighting and thermal needs.\",\"PeriodicalId\":36795,\"journal\":{\"name\":\"Journal of Sustainable Architecture and Civil Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sustainable Architecture and Civil Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5755/j01.sace.29.2.28008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sustainable Architecture and Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5755/j01.sace.29.2.28008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 3

摘要

近年来,大型玻璃幕墙建筑的比例正在迅速增加,特别是在办公楼中。其中,创造合适的热舒适和视觉舒适是影响生产力的重要因素。没有适当遮阳措施的大型玻璃立面的使用会产生热和视觉上的不适,从不舒适的环境条件到严重的健康影响。在半干旱气候条件下,大型玻璃办公楼的性能评估与环境相关的专业工作和文献缺乏,而半干旱气候条件的特点是一年中的夏季太阳辐射强度很大。本研究以位于阿尔及利亚半干旱气候(北纬36°,17°和东经7°,23′)的自然通风办公楼为样本,调查了大型玻璃区域对热舒适性和视觉舒适性的影响。为此,采用了一种使用后评估技术(POE),这是建筑运行阶段过程中的主流活动。主要目的是强调从业者,特别是建筑师,在设计过程的早期阶段做出有意识的决定。这项研究明确强调了办公楼内的不适。它包括玻璃幕墙引起的不可接受的温度;过度的太阳能增益导致的过热;通风不足,采光差。结果表明,在夏季不建议采用这种大开窗系统。然而,通过模拟工具明智地选择玻璃尺寸和类型必须平衡照明和热需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A study of Indoor Environment of Large Glazed Office Building in Semi Arid Climate
In recent years the rate of buildings with large glazed facades is rapidly increasing, particularly in office buildings. Where, the creation of a suitable thermal and visual comfort is a significant factor affecting productivity. The use of large glazed facades without adapted shading measure generates thermal and visual discomfort, wich ranges from uncomfortable environment conditions to serious health effects. Specialized work and literature about performance evaluation of large glazed office buildings in relation to their environment are lacking in semi arid climates, characterized by significant intensity of solar radiations in the summer period of the year. This study investigates the impact of large glazing areas on thermal and visual comfort in a sample of naturally ventilated office building located in the semi arid climate of Algeria (36°, 17 N and 7°, 23’ E). A Post Occupancy Evaluation technique (POE), being a mainstream activity in the process of building operation phase is used for this purpose. The main objective is to stress practitioners, specifically architects, to take conscious decisions in an early phase of design process. The study clearly highlighted discomfort in the studied office building. It included unacceptable temperature arising from glazed facade; overheating due to excessive solar gains; insufficient ventilation and poor daylighting. The results indicate that such large fenestration system is not recommended in summer time. However, a judicious choice of the glazing size and type by simulation tools must balance lighting and thermal needs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
21
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信