一种基于二氧化钛的丙醇厚膜气体传感器

IF 2.2 Q3 MATERIALS SCIENCE, MULTIDISCIPLINARY
Ankit Kumar Vishwakarma , Ajaya Kumar Sharma , Ashok Kumar Mishra , Lallan Yadava
{"title":"一种基于二氧化钛的丙醇厚膜气体传感器","authors":"Ankit Kumar Vishwakarma ,&nbsp;Ajaya Kumar Sharma ,&nbsp;Ashok Kumar Mishra ,&nbsp;Lallan Yadava","doi":"10.1016/j.mlblux.2023.100184","DOIUrl":null,"url":null,"abstract":"<div><p>In the present paper, we reported the sensing behavior and mechanism of a titanium dioxide-based thick film sensor for the detection of propanol at room temperature. Undoped titanium dioxide (UTO) and 2 wt% cadmium sulfide doped titanium dioxide (CdTO) thick film samples are fabricated on an alumina substrate. The response of the fabricated samples is measured with varying concentrations of propanol (0–5000 ppm) in a testing chamber at room temperature. The measurement showed that the 2 wt% CdS doped sample showed a maximum response (63 %) for propanol. The transient response is also measured and the response time is 65 s and recovery 195 s.</p></div>","PeriodicalId":18245,"journal":{"name":"Materials Letters: X","volume":"17 ","pages":"Article 100184"},"PeriodicalIF":2.2000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A titanium dioxide-based thick film gas sensor for propanol\",\"authors\":\"Ankit Kumar Vishwakarma ,&nbsp;Ajaya Kumar Sharma ,&nbsp;Ashok Kumar Mishra ,&nbsp;Lallan Yadava\",\"doi\":\"10.1016/j.mlblux.2023.100184\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In the present paper, we reported the sensing behavior and mechanism of a titanium dioxide-based thick film sensor for the detection of propanol at room temperature. Undoped titanium dioxide (UTO) and 2 wt% cadmium sulfide doped titanium dioxide (CdTO) thick film samples are fabricated on an alumina substrate. The response of the fabricated samples is measured with varying concentrations of propanol (0–5000 ppm) in a testing chamber at room temperature. The measurement showed that the 2 wt% CdS doped sample showed a maximum response (63 %) for propanol. The transient response is also measured and the response time is 65 s and recovery 195 s.</p></div>\",\"PeriodicalId\":18245,\"journal\":{\"name\":\"Materials Letters: X\",\"volume\":\"17 \",\"pages\":\"Article 100184\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Materials Letters: X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590150823000042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Letters: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590150823000042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本文报道了一种二氧化钛基厚膜传感器在室温下检测丙醇的传感行为和机理。在氧化铝衬底上制备了未掺杂二氧化钛(UTO)和2 wt%硫化镉掺杂二氧化钛(CdTO)厚膜样品。在室温下的测试室中,用不同浓度的丙醇(0 - 5000ppm)测量制备样品的响应。测量结果表明,2 wt%的CdS掺杂样品对丙醇的响应最大(63%)。测量了瞬态响应,响应时间为65 s,恢复时间为195 s。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A titanium dioxide-based thick film gas sensor for propanol

A titanium dioxide-based thick film gas sensor for propanol

In the present paper, we reported the sensing behavior and mechanism of a titanium dioxide-based thick film sensor for the detection of propanol at room temperature. Undoped titanium dioxide (UTO) and 2 wt% cadmium sulfide doped titanium dioxide (CdTO) thick film samples are fabricated on an alumina substrate. The response of the fabricated samples is measured with varying concentrations of propanol (0–5000 ppm) in a testing chamber at room temperature. The measurement showed that the 2 wt% CdS doped sample showed a maximum response (63 %) for propanol. The transient response is also measured and the response time is 65 s and recovery 195 s.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
50
审稿时长
114 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信