实验室后退致动器和火炮发射的爆炸适用性

E. Baker
{"title":"实验室后退致动器和火炮发射的爆炸适用性","authors":"E. Baker","doi":"10.5604/01.3001.0013.0793","DOIUrl":null,"url":null,"abstract":"There is currently no agreed standard methodology for assessing the suitability of explosives for gun launch or for the determination of acceptance criteria for explosive fill defects. Laboratory setback activator testing has been used as an assessment tool for investigating the suitability of explosives for gun launch. Unfortunately, laboratory setback activator testing is not standardized and large variations exist in activator design, function, and results between different laboratories. However, it is the only currently available tool for assessing an explosives safety and suitability to launch-induced setback forces. In laboratory setback activator tests, ignitions are observed at setback loadings that are much higher than produced in actual gun launched projectiles. This may be related to the defects in actual projectiles, which appear to be very different than the laboratory tests.\n\n","PeriodicalId":52820,"journal":{"name":"Problemy Mechatroniki","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Laboratory Setback Actuators and Explosive Suitability for Gun Launch\",\"authors\":\"E. Baker\",\"doi\":\"10.5604/01.3001.0013.0793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There is currently no agreed standard methodology for assessing the suitability of explosives for gun launch or for the determination of acceptance criteria for explosive fill defects. Laboratory setback activator testing has been used as an assessment tool for investigating the suitability of explosives for gun launch. Unfortunately, laboratory setback activator testing is not standardized and large variations exist in activator design, function, and results between different laboratories. However, it is the only currently available tool for assessing an explosives safety and suitability to launch-induced setback forces. In laboratory setback activator tests, ignitions are observed at setback loadings that are much higher than produced in actual gun launched projectiles. This may be related to the defects in actual projectiles, which appear to be very different than the laboratory tests.\\n\\n\",\"PeriodicalId\":52820,\"journal\":{\"name\":\"Problemy Mechatroniki\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Problemy Mechatroniki\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0013.0793\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Problemy Mechatroniki","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0013.0793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目前还没有商定的标准方法来评估炸药是否适合用枪发射或确定炸药填充缺陷的接受标准。实验室挫折激发剂试验已被用作调查炸药是否适合火炮发射的评估工具。不幸的是,实验室挫折激活剂测试没有标准化,不同实验室之间的激活剂设计、功能和结果存在很大差异。然而,它是目前唯一可用的工具,用于评估爆炸物的安全性和发射引起的挫折力的适用性。在实验室挫折激活试验中,观察到的挫折载荷比实际火炮发射的炮弹产生的载荷高得多。这可能与实际弹丸的缺陷有关,这些缺陷似乎与实验室测试结果大不相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Laboratory Setback Actuators and Explosive Suitability for Gun Launch
There is currently no agreed standard methodology for assessing the suitability of explosives for gun launch or for the determination of acceptance criteria for explosive fill defects. Laboratory setback activator testing has been used as an assessment tool for investigating the suitability of explosives for gun launch. Unfortunately, laboratory setback activator testing is not standardized and large variations exist in activator design, function, and results between different laboratories. However, it is the only currently available tool for assessing an explosives safety and suitability to launch-induced setback forces. In laboratory setback activator tests, ignitions are observed at setback loadings that are much higher than produced in actual gun launched projectiles. This may be related to the defects in actual projectiles, which appear to be very different than the laboratory tests.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
23
审稿时长
53 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信