用红外相机评价黑体表面温度均匀性的实验研究

IF 3.7 3区 工程技术 Q1 INSTRUMENTS & INSTRUMENTATION
S. Yoon, J.C. Park, Y. J. Cho
{"title":"用红外相机评价黑体表面温度均匀性的实验研究","authors":"S. Yoon, J.C. Park, Y. J. Cho","doi":"10.1080/17686733.2021.1877918","DOIUrl":null,"url":null,"abstract":"ABSTRACT Blackbody radiation is standardised electromagnetic energy emitted into space at a given temperature and wavelength distribution. It is used as a reference model to compare radiation emitted from various objects. This reference performance of blackbody systems should be maintained through periodic inspection and calibration. In this study, temperature uniformity on the surface of the blackbody was evaluated using infrared cameras. To this end, we divided the blackbody system measurements into ‘before’ and ‘after’ calibration sets and examined the blackbody surface in different bands, using two infrared cameras with different measurement principles. To evaluate surface temperature uniformity, we calculated the signal transfer function, equivalent noise temperature difference, and 3D noise of the infrared detector, and then comparatively analysed them.","PeriodicalId":54525,"journal":{"name":"Quantitative Infrared Thermography Journal","volume":"19 1","pages":"172 - 186"},"PeriodicalIF":3.7000,"publicationDate":"2021-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/17686733.2021.1877918","citationCount":"15","resultStr":"{\"title\":\"An experimental study on the evaluation of temperature uniformity on the surface of a blackbody using infrared cameras\",\"authors\":\"S. Yoon, J.C. Park, Y. J. Cho\",\"doi\":\"10.1080/17686733.2021.1877918\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Blackbody radiation is standardised electromagnetic energy emitted into space at a given temperature and wavelength distribution. It is used as a reference model to compare radiation emitted from various objects. This reference performance of blackbody systems should be maintained through periodic inspection and calibration. In this study, temperature uniformity on the surface of the blackbody was evaluated using infrared cameras. To this end, we divided the blackbody system measurements into ‘before’ and ‘after’ calibration sets and examined the blackbody surface in different bands, using two infrared cameras with different measurement principles. To evaluate surface temperature uniformity, we calculated the signal transfer function, equivalent noise temperature difference, and 3D noise of the infrared detector, and then comparatively analysed them.\",\"PeriodicalId\":54525,\"journal\":{\"name\":\"Quantitative Infrared Thermography Journal\",\"volume\":\"19 1\",\"pages\":\"172 - 186\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2021-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/17686733.2021.1877918\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quantitative Infrared Thermography Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/17686733.2021.1877918\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quantitative Infrared Thermography Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17686733.2021.1877918","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 15

摘要

黑体辐射是在给定温度和波长分布下发射到空间中的标准化电磁能。它被用作比较不同物体发出的辐射的参考模型。应通过定期检查和校准来保持黑体系统的这种参考性能。本研究利用红外摄像机对黑体表面的温度均匀性进行了评价。为此,我们将黑体系统测量分为“前”和“后”校准集,使用两台测量原理不同的红外相机,在不同波段对黑体表面进行了检测。为了评价红外探测器的表面温度均匀性,我们计算了红外探测器的信号传递函数、等效噪声温差和三维噪声,并对它们进行了对比分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An experimental study on the evaluation of temperature uniformity on the surface of a blackbody using infrared cameras
ABSTRACT Blackbody radiation is standardised electromagnetic energy emitted into space at a given temperature and wavelength distribution. It is used as a reference model to compare radiation emitted from various objects. This reference performance of blackbody systems should be maintained through periodic inspection and calibration. In this study, temperature uniformity on the surface of the blackbody was evaluated using infrared cameras. To this end, we divided the blackbody system measurements into ‘before’ and ‘after’ calibration sets and examined the blackbody surface in different bands, using two infrared cameras with different measurement principles. To evaluate surface temperature uniformity, we calculated the signal transfer function, equivalent noise temperature difference, and 3D noise of the infrared detector, and then comparatively analysed them.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Quantitative Infrared Thermography Journal
Quantitative Infrared Thermography Journal Physics and Astronomy-Instrumentation
CiteScore
6.80
自引率
12.00%
发文量
17
审稿时长
>12 weeks
期刊介绍: The Quantitative InfraRed Thermography Journal (QIRT) provides a forum for industry and academia to discuss the latest developments of instrumentation, theoretical and experimental practices, data reduction, and image processing related to infrared thermography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信