{"title":"一个新颖的屋顶改造概念的结构和耐久性分析","authors":"R. Richman, E. Bentz, Denver Jermyn, Chang Sun","doi":"10.3846/2029882X.2017.1404939","DOIUrl":null,"url":null,"abstract":"Metal roof decks in long-span light steel structures can become damaged and obsolete by corrosion should the roofing system become compromised. Re-roofing is conducted by either removing and replacing damaged areas (resulting in suspension of interior operations and lost revenue) or installing new decking directly over the damaged areas which can transfer corrosion to the new deck. This research conducts structural and durability analyses on a novel proposed re-roofing concept that installs a new metal roof deck over the existing deck by using a proprietary deck strap resulting in no interruption of interior processes. Preliminary structural analysis shows the proposed concept to be applicable to generic conditions around Southern Ontario. Recommendations for project specific structural analysis are made. Durability analysis demonstrates that the proposed concept system improves hygrothermal performance of the roof assembly in all cases except when insulation in the existing roof assembly is saturated. Saturated insulation should be removed prior to installing the re-roofing system.","PeriodicalId":11839,"journal":{"name":"Engineering Structures and Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3846/2029882X.2017.1404939","citationCount":"0","resultStr":"{\"title\":\"Structural and durability analysis of a novel re-roofing concept\",\"authors\":\"R. Richman, E. Bentz, Denver Jermyn, Chang Sun\",\"doi\":\"10.3846/2029882X.2017.1404939\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Metal roof decks in long-span light steel structures can become damaged and obsolete by corrosion should the roofing system become compromised. Re-roofing is conducted by either removing and replacing damaged areas (resulting in suspension of interior operations and lost revenue) or installing new decking directly over the damaged areas which can transfer corrosion to the new deck. This research conducts structural and durability analyses on a novel proposed re-roofing concept that installs a new metal roof deck over the existing deck by using a proprietary deck strap resulting in no interruption of interior processes. Preliminary structural analysis shows the proposed concept to be applicable to generic conditions around Southern Ontario. Recommendations for project specific structural analysis are made. Durability analysis demonstrates that the proposed concept system improves hygrothermal performance of the roof assembly in all cases except when insulation in the existing roof assembly is saturated. Saturated insulation should be removed prior to installing the re-roofing system.\",\"PeriodicalId\":11839,\"journal\":{\"name\":\"Engineering Structures and Technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3846/2029882X.2017.1404939\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering Structures and Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3846/2029882X.2017.1404939\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Structures and Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3846/2029882X.2017.1404939","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Structural and durability analysis of a novel re-roofing concept
Metal roof decks in long-span light steel structures can become damaged and obsolete by corrosion should the roofing system become compromised. Re-roofing is conducted by either removing and replacing damaged areas (resulting in suspension of interior operations and lost revenue) or installing new decking directly over the damaged areas which can transfer corrosion to the new deck. This research conducts structural and durability analyses on a novel proposed re-roofing concept that installs a new metal roof deck over the existing deck by using a proprietary deck strap resulting in no interruption of interior processes. Preliminary structural analysis shows the proposed concept to be applicable to generic conditions around Southern Ontario. Recommendations for project specific structural analysis are made. Durability analysis demonstrates that the proposed concept system improves hygrothermal performance of the roof assembly in all cases except when insulation in the existing roof assembly is saturated. Saturated insulation should be removed prior to installing the re-roofing system.