D. Saenz, N. Papanikolaou, E. Zoros, E. Pappas, M. Reiner, Lip Teck Chew, Hooi Yin Lim, S. Hancock, A. Nevelsky, C. Njeh, G. Anagnostopoulos
{"title":"跨机构单等中心多转移立体定向放射外科端到端测试的稳健性","authors":"D. Saenz, N. Papanikolaou, E. Zoros, E. Pappas, M. Reiner, Lip Teck Chew, Hooi Yin Lim, S. Hancock, A. Nevelsky, C. Njeh, G. Anagnostopoulos","doi":"10.21203/rs.3.rs-15983/v1","DOIUrl":null,"url":null,"abstract":"The accuracy of stereotactic radiosurgery (SRS) to multiple metastases with a single-isocenter using high definition dynamic radiosurgery (HDRS) was evaluated across institutions. An SRS plan was delivered at six HDRS-capable institutions to an anthropomorphic phantom consisting of point, film, and 3D-gel dosimeters. Direct dose comparison and gamma analysis were used to evaluate the accuracy. Point measurements averaged across institutions were within 1.2±0.5%. The average gamma passing rate in the film was 96.6±2.2% (3%/2 mm). For targets within 4 cm of the isocenter, the 3D dosimetric gel gamma passing rate averaged across institutions was >90% (3%/2 mm). The targeting accuracy of high definition dynamic radiosurgery assessed by geometrical offset of the center of dose distributions across multiple institutions in this study was within 1 mm for targets within 4 cm of isocenter. Across variations in clinical practice, comparable dosimetry and localization is possible with this treatment planning and delivery technique.","PeriodicalId":16917,"journal":{"name":"Journal of radiosurgery and SBRT","volume":"7 1","pages":"223 - 232"},"PeriodicalIF":0.7000,"publicationDate":"2020-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Robustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions\",\"authors\":\"D. Saenz, N. Papanikolaou, E. Zoros, E. Pappas, M. Reiner, Lip Teck Chew, Hooi Yin Lim, S. Hancock, A. Nevelsky, C. Njeh, G. Anagnostopoulos\",\"doi\":\"10.21203/rs.3.rs-15983/v1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The accuracy of stereotactic radiosurgery (SRS) to multiple metastases with a single-isocenter using high definition dynamic radiosurgery (HDRS) was evaluated across institutions. An SRS plan was delivered at six HDRS-capable institutions to an anthropomorphic phantom consisting of point, film, and 3D-gel dosimeters. Direct dose comparison and gamma analysis were used to evaluate the accuracy. Point measurements averaged across institutions were within 1.2±0.5%. The average gamma passing rate in the film was 96.6±2.2% (3%/2 mm). For targets within 4 cm of the isocenter, the 3D dosimetric gel gamma passing rate averaged across institutions was >90% (3%/2 mm). The targeting accuracy of high definition dynamic radiosurgery assessed by geometrical offset of the center of dose distributions across multiple institutions in this study was within 1 mm for targets within 4 cm of isocenter. Across variations in clinical practice, comparable dosimetry and localization is possible with this treatment planning and delivery technique.\",\"PeriodicalId\":16917,\"journal\":{\"name\":\"Journal of radiosurgery and SBRT\",\"volume\":\"7 1\",\"pages\":\"223 - 232\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2020-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of radiosurgery and SBRT\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21203/rs.3.rs-15983/v1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of radiosurgery and SBRT","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21203/rs.3.rs-15983/v1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
Robustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions
The accuracy of stereotactic radiosurgery (SRS) to multiple metastases with a single-isocenter using high definition dynamic radiosurgery (HDRS) was evaluated across institutions. An SRS plan was delivered at six HDRS-capable institutions to an anthropomorphic phantom consisting of point, film, and 3D-gel dosimeters. Direct dose comparison and gamma analysis were used to evaluate the accuracy. Point measurements averaged across institutions were within 1.2±0.5%. The average gamma passing rate in the film was 96.6±2.2% (3%/2 mm). For targets within 4 cm of the isocenter, the 3D dosimetric gel gamma passing rate averaged across institutions was >90% (3%/2 mm). The targeting accuracy of high definition dynamic radiosurgery assessed by geometrical offset of the center of dose distributions across multiple institutions in this study was within 1 mm for targets within 4 cm of isocenter. Across variations in clinical practice, comparable dosimetry and localization is possible with this treatment planning and delivery technique.