N. Uçar, Gökçen Gökçeli, Ilkay Ozsev Yuksek, A. Onen, N. Karatepe
{"title":"凝固时间、凝固浴次数和成分对连续氧化石墨烯纤维性能的影响","authors":"N. Uçar, Gökçen Gökçeli, Ilkay Ozsev Yuksek, A. Onen, N. Karatepe","doi":"10.5072/ZENODO.38720","DOIUrl":null,"url":null,"abstract":"The effect of coagulation time, the number of coagulation bath and ingredients on the properties of continuous graphene oxide fibre has been analyzed. It is observed that the number of coagulation baths and coagulation time affect the fibre morphology, electrical conductivity, and tenacity of fibre. Also, addition of the ingredient (ethylenediamine) results in lower strength and highest fibre count together with darker, curly, and rough fibre structure. It can be suggested that among all the samples, the sample with 1 coagulation bath and 2 min coagulation time can be preferred if electrical conductivity is more important than fibre tenacity. However, if fibre tenacity is the issue, preference of the sample with 3 coagulation baths and 2 min coagulation time will be more convenient.","PeriodicalId":13444,"journal":{"name":"Indian Journal of Fibre & Textile Research","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2018-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effect of coagulation time, number of coagulation bath and ingredients on properties of continuous graphene oxide fibre\",\"authors\":\"N. Uçar, Gökçen Gökçeli, Ilkay Ozsev Yuksek, A. Onen, N. Karatepe\",\"doi\":\"10.5072/ZENODO.38720\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of coagulation time, the number of coagulation bath and ingredients on the properties of continuous graphene oxide fibre has been analyzed. It is observed that the number of coagulation baths and coagulation time affect the fibre morphology, electrical conductivity, and tenacity of fibre. Also, addition of the ingredient (ethylenediamine) results in lower strength and highest fibre count together with darker, curly, and rough fibre structure. It can be suggested that among all the samples, the sample with 1 coagulation bath and 2 min coagulation time can be preferred if electrical conductivity is more important than fibre tenacity. However, if fibre tenacity is the issue, preference of the sample with 3 coagulation baths and 2 min coagulation time will be more convenient.\",\"PeriodicalId\":13444,\"journal\":{\"name\":\"Indian Journal of Fibre & Textile Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2018-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Fibre & Textile Research\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.5072/ZENODO.38720\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATERIALS SCIENCE, TEXTILES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Fibre & Textile Research","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.5072/ZENODO.38720","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, TEXTILES","Score":null,"Total":0}
Effect of coagulation time, number of coagulation bath and ingredients on properties of continuous graphene oxide fibre
The effect of coagulation time, the number of coagulation bath and ingredients on the properties of continuous graphene oxide fibre has been analyzed. It is observed that the number of coagulation baths and coagulation time affect the fibre morphology, electrical conductivity, and tenacity of fibre. Also, addition of the ingredient (ethylenediamine) results in lower strength and highest fibre count together with darker, curly, and rough fibre structure. It can be suggested that among all the samples, the sample with 1 coagulation bath and 2 min coagulation time can be preferred if electrical conductivity is more important than fibre tenacity. However, if fibre tenacity is the issue, preference of the sample with 3 coagulation baths and 2 min coagulation time will be more convenient.
期刊介绍:
Started in 1976, this journal publishes papers on both fundamental and applied research in various branches of textile technology and allied areas such as Production and properties of natural and synthetic fibres (including industrial fibres), yarns and fabrics; Physics and chemistry of fibre forming polymers; Chemical and finishing processes; Fibre-reinforced composites; Garment technology; Analysis, testing and quality control; Application of microprocessors; Instrumentation; application of nanotechnology in textiles; and Industrial engineering.