流动库仑法测定水中磷酸盐

IF 0.9 Q4 CHEMISTRY, MULTIDISCIPLINARY
A. Manová, E. Beinrohr
{"title":"流动库仑法测定水中磷酸盐","authors":"A. Manová, E. Beinrohr","doi":"10.2478/acs-2020-0015","DOIUrl":null,"url":null,"abstract":"Abstract In this work, the possibility of flow coulometry application as coulometric titration was studied. The method was used to analyze phosphates in wastewater samples. The principle of the determination consisted in the formation of molybdophosphate and its subsequent one-electron electrolytic reduction. The present method is applicable under optimal conditions in the concentration range of 1.5 × 10−6 to 5.5 × 10−5 mol/dm3. Detection limit of the method is 3.42 × 10−7 mol/dm3. Mineralization step has been proved a problem in total phosphate content determination. If mineralization was not carried out, only inorganic soluble phosphates were determined. It is a new method characterized by its simplicity of instrumentation and handling, which is a prerequisite for its further use in the field of trace analysis.","PeriodicalId":7088,"journal":{"name":"Acta Chimica Slovaca","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Determination of phosphate in water by flow coulometry\",\"authors\":\"A. Manová, E. Beinrohr\",\"doi\":\"10.2478/acs-2020-0015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract In this work, the possibility of flow coulometry application as coulometric titration was studied. The method was used to analyze phosphates in wastewater samples. The principle of the determination consisted in the formation of molybdophosphate and its subsequent one-electron electrolytic reduction. The present method is applicable under optimal conditions in the concentration range of 1.5 × 10−6 to 5.5 × 10−5 mol/dm3. Detection limit of the method is 3.42 × 10−7 mol/dm3. Mineralization step has been proved a problem in total phosphate content determination. If mineralization was not carried out, only inorganic soluble phosphates were determined. It is a new method characterized by its simplicity of instrumentation and handling, which is a prerequisite for its further use in the field of trace analysis.\",\"PeriodicalId\":7088,\"journal\":{\"name\":\"Acta Chimica Slovaca\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2020-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Chimica Slovaca\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/acs-2020-0015\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chimica Slovaca","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/acs-2020-0015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 5

摘要

本文研究了流动电量法作为电量滴定法应用的可能性。该方法用于分析废水样品中的磷酸盐。测定原理包括磷钼的形成及其随后的单电子电解还原。本方法适用于1.5×10−6至5.5×10−5 mol/dm3浓度范围内的最佳条件。方法的检出限为3.42×10−7mol/dm3。矿化步骤已被证明是测定总磷酸盐含量的一个问题。如果不进行矿化,则只测定无机可溶性磷酸盐。这是一种新方法,其特点是仪器和处理简单,这是它在痕量分析领域进一步应用的先决条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of phosphate in water by flow coulometry
Abstract In this work, the possibility of flow coulometry application as coulometric titration was studied. The method was used to analyze phosphates in wastewater samples. The principle of the determination consisted in the formation of molybdophosphate and its subsequent one-electron electrolytic reduction. The present method is applicable under optimal conditions in the concentration range of 1.5 × 10−6 to 5.5 × 10−5 mol/dm3. Detection limit of the method is 3.42 × 10−7 mol/dm3. Mineralization step has been proved a problem in total phosphate content determination. If mineralization was not carried out, only inorganic soluble phosphates were determined. It is a new method characterized by its simplicity of instrumentation and handling, which is a prerequisite for its further use in the field of trace analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Chimica Slovaca
Acta Chimica Slovaca CHEMISTRY, MULTIDISCIPLINARY-
自引率
12.50%
发文量
11
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信