儿科头部CT程序的局部诊断参考水平

Q3 Medicine
B. Gricienė, Monika Šiukšterytė
{"title":"儿科头部CT程序的局部诊断参考水平","authors":"B. Gricienė, Monika Šiukšterytė","doi":"10.15388/Amed.2021.28.2.13","DOIUrl":null,"url":null,"abstract":"Background. Patients, especially children, are exposed to substantially high doses of ionising radiation during computed tomography (CT) procedures. Children are several times more susceptible to ionising radiation than adults. Diagnostic reference levels (DRLs) are an important tool for monitoring and optimising patient radiation exposure from radiological procedures. The aim of this study is to estimate the ionising radiation exposure doses and set local DRLs for head CT examinations according to age and to compare local DRLs with national and European DRLs and with literature data in other countries. Materials and methods. Scan parameters of single-phase head CT examinations were collected. Patients were grouped by age in the following intervals: <1, 1−5, 5−10, 10−15 and 15−18 years. Local age-based DRLs set as the 3rd quartile of the median dose-length product (DLP) were calculated. Literature analysis was performed on PubMed search engine on inclusion criteria: publication date 2015–2020, used keywords paediatric computed tomography, paediatric CT, diagnostic reference levels (DRLs). The 23 articles discussing paediatric DRLs were further analysed. Results. Data was collected from 194 paediatric head CT examinations performed in 2019. The median DLP values for head CT were 144.3, 233.7, 246.4, 288.9, 315.5 for <1, 1−5, 5−10, 10−15 and 15−18 years old groups. Estimated local DRLs for head CT examinations are 170, 300, 310, 320, 360 mGy*cm for <1, 1−5, 5−10, 10−15 and 15−18 years age groups respectively and 130, 210, 275, 320 mGy*cm for 0−3 months, 3 months−1 year, 1−6 years and ≥ 6 years age groups respectively. Conclusions. Results of this study showed that settled new local DRLs of head CT examinations were 2–4 times lower than national DRLs and about 2 times lower than European DRLs. Moreover, the study indicated that paediatric head CT doses are significantly lower in comparison with those indicated in the majority of published data from other hospitals over the last 6 years. Patient dose assessment and local DRLs establishment plays important role in future exposure optimisation.","PeriodicalId":34365,"journal":{"name":"Acta Medica Lituanica","volume":"28 1","pages":"253 - 261"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Local Diagnostic Reference Levels for Paediatric Head CT Procedures\",\"authors\":\"B. Gricienė, Monika Šiukšterytė\",\"doi\":\"10.15388/Amed.2021.28.2.13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background. Patients, especially children, are exposed to substantially high doses of ionising radiation during computed tomography (CT) procedures. Children are several times more susceptible to ionising radiation than adults. Diagnostic reference levels (DRLs) are an important tool for monitoring and optimising patient radiation exposure from radiological procedures. The aim of this study is to estimate the ionising radiation exposure doses and set local DRLs for head CT examinations according to age and to compare local DRLs with national and European DRLs and with literature data in other countries. Materials and methods. Scan parameters of single-phase head CT examinations were collected. Patients were grouped by age in the following intervals: <1, 1−5, 5−10, 10−15 and 15−18 years. Local age-based DRLs set as the 3rd quartile of the median dose-length product (DLP) were calculated. Literature analysis was performed on PubMed search engine on inclusion criteria: publication date 2015–2020, used keywords paediatric computed tomography, paediatric CT, diagnostic reference levels (DRLs). The 23 articles discussing paediatric DRLs were further analysed. Results. Data was collected from 194 paediatric head CT examinations performed in 2019. The median DLP values for head CT were 144.3, 233.7, 246.4, 288.9, 315.5 for <1, 1−5, 5−10, 10−15 and 15−18 years old groups. Estimated local DRLs for head CT examinations are 170, 300, 310, 320, 360 mGy*cm for <1, 1−5, 5−10, 10−15 and 15−18 years age groups respectively and 130, 210, 275, 320 mGy*cm for 0−3 months, 3 months−1 year, 1−6 years and ≥ 6 years age groups respectively. Conclusions. Results of this study showed that settled new local DRLs of head CT examinations were 2–4 times lower than national DRLs and about 2 times lower than European DRLs. Moreover, the study indicated that paediatric head CT doses are significantly lower in comparison with those indicated in the majority of published data from other hospitals over the last 6 years. Patient dose assessment and local DRLs establishment plays important role in future exposure optimisation.\",\"PeriodicalId\":34365,\"journal\":{\"name\":\"Acta Medica Lituanica\",\"volume\":\"28 1\",\"pages\":\"253 - 261\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Medica Lituanica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15388/Amed.2021.28.2.13\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Medica Lituanica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15388/Amed.2021.28.2.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

背景患者,尤其是儿童,在计算机断层扫描(CT)过程中暴露于相当高剂量的电离辐射。儿童比成年人更容易受到电离辐射的影响。诊断参考水平(DRL)是监测和优化放射手术患者辐射暴露的重要工具。本研究的目的是估计电离辐射暴露剂量,并根据年龄设置头部CT检查的局部DRL,并将局部DRL与国家和欧洲的DRL以及其他国家的文献数据进行比较。材料和方法。收集单相头部CT检查的扫描参数。患者按年龄分组,时间间隔如下:<1、1-5、5-10、10-15和15-18岁。计算设定为中位剂量-长度乘积(DLP)第三个四分位数的局部基于年龄的DRL。在PubMed搜索引擎上对纳入标准进行文献分析:发表日期:2015-2020,使用关键词儿科计算机断层扫描、儿科CT、诊断参考水平(DRL)。对23篇讨论儿科DRL的文章进行了进一步分析。后果数据收集自2019年进行的194次儿科头部CT检查。<1、1−5、5−10、10−15和15−18岁组的头部CT DLP中值分别为144.3、233.7、246.4、288.9、315.5。头部CT检查的局部DRLs估计值,<1、1−5、5−10、10−15和15−18岁年龄组分别为170、300、310、320、360 mGy*cm,0−3个月、3个月-1年、1−6岁和≥6岁年龄组则分别为130、210、275、320 mGy*cm。结论。这项研究的结果表明,头部CT检查中确定的新的局部DRL比国家DRL低2-4倍,比欧洲DRL低约2倍。此外,该研究表明,与过去6年其他医院公布的大多数数据相比,儿科头部CT剂量明显较低。患者剂量评估和局部DRL的建立在未来暴露优化中发挥着重要作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Local Diagnostic Reference Levels for Paediatric Head CT Procedures
Background. Patients, especially children, are exposed to substantially high doses of ionising radiation during computed tomography (CT) procedures. Children are several times more susceptible to ionising radiation than adults. Diagnostic reference levels (DRLs) are an important tool for monitoring and optimising patient radiation exposure from radiological procedures. The aim of this study is to estimate the ionising radiation exposure doses and set local DRLs for head CT examinations according to age and to compare local DRLs with national and European DRLs and with literature data in other countries. Materials and methods. Scan parameters of single-phase head CT examinations were collected. Patients were grouped by age in the following intervals: <1, 1−5, 5−10, 10−15 and 15−18 years. Local age-based DRLs set as the 3rd quartile of the median dose-length product (DLP) were calculated. Literature analysis was performed on PubMed search engine on inclusion criteria: publication date 2015–2020, used keywords paediatric computed tomography, paediatric CT, diagnostic reference levels (DRLs). The 23 articles discussing paediatric DRLs were further analysed. Results. Data was collected from 194 paediatric head CT examinations performed in 2019. The median DLP values for head CT were 144.3, 233.7, 246.4, 288.9, 315.5 for <1, 1−5, 5−10, 10−15 and 15−18 years old groups. Estimated local DRLs for head CT examinations are 170, 300, 310, 320, 360 mGy*cm for <1, 1−5, 5−10, 10−15 and 15−18 years age groups respectively and 130, 210, 275, 320 mGy*cm for 0−3 months, 3 months−1 year, 1−6 years and ≥ 6 years age groups respectively. Conclusions. Results of this study showed that settled new local DRLs of head CT examinations were 2–4 times lower than national DRLs and about 2 times lower than European DRLs. Moreover, the study indicated that paediatric head CT doses are significantly lower in comparison with those indicated in the majority of published data from other hospitals over the last 6 years. Patient dose assessment and local DRLs establishment plays important role in future exposure optimisation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Medica Lituanica
Acta Medica Lituanica Medicine-General Medicine
CiteScore
0.70
自引率
0.00%
发文量
33
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信