T. Ahmadzadeh, E. Babaei, M. Sabahi, T. Abedinzadeh
{"title":"一种改进的无变压器并网光伏系统及其控制策略以降低漏电流、提取最大功率点和控制功率","authors":"T. Ahmadzadeh, E. Babaei, M. Sabahi, T. Abedinzadeh","doi":"10.22068/IJEEE.16.4.513","DOIUrl":null,"url":null,"abstract":"The main purposes of a transformerless grid-connected photovoltaic (PV) system consist of the reduction of leakage current, extraction of maximum power point (MPP), tracking of MPP (MPPT), controlling the active and reactive powers, and having the unity power factor. To achieve the above-mentioned aims, the following actions have been performed in this paper. First of all, a brief analysis of the transformerless PV system has been done by using the conventional full-bridge (FB) topologies with two bipolar and unipolar PWM techniques. Then, an effective solution has been also introduced to significantly reduce the leakage current in the conventional H5 FB topology. Moreover, a proper control method has been proposed by using the combination of the fractional opencircuit voltage (FOCV) and the model predictive control (MPC) strategies to extract the MPP from PV panels, control the injection of the reactive power to the gird and have the unity power factor. At last, the simulation results performed in PSCAD software will be used to prove the correct performance of the proposed control method in the improved H5 FB topology.","PeriodicalId":39055,"journal":{"name":"Iranian Journal of Electrical and Electronic Engineering","volume":"16 1","pages":"513-523"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"An Improved Transformerless Grid-Connected PV System With Related Control Strategy to Reduce Leakage Current, Extract Maximum Power Point and Control Power\",\"authors\":\"T. Ahmadzadeh, E. Babaei, M. Sabahi, T. Abedinzadeh\",\"doi\":\"10.22068/IJEEE.16.4.513\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main purposes of a transformerless grid-connected photovoltaic (PV) system consist of the reduction of leakage current, extraction of maximum power point (MPP), tracking of MPP (MPPT), controlling the active and reactive powers, and having the unity power factor. To achieve the above-mentioned aims, the following actions have been performed in this paper. First of all, a brief analysis of the transformerless PV system has been done by using the conventional full-bridge (FB) topologies with two bipolar and unipolar PWM techniques. Then, an effective solution has been also introduced to significantly reduce the leakage current in the conventional H5 FB topology. Moreover, a proper control method has been proposed by using the combination of the fractional opencircuit voltage (FOCV) and the model predictive control (MPC) strategies to extract the MPP from PV panels, control the injection of the reactive power to the gird and have the unity power factor. At last, the simulation results performed in PSCAD software will be used to prove the correct performance of the proposed control method in the improved H5 FB topology.\",\"PeriodicalId\":39055,\"journal\":{\"name\":\"Iranian Journal of Electrical and Electronic Engineering\",\"volume\":\"16 1\",\"pages\":\"513-523\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Electrical and Electronic Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22068/IJEEE.16.4.513\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Energy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Electrical and Electronic Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22068/IJEEE.16.4.513","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
An Improved Transformerless Grid-Connected PV System With Related Control Strategy to Reduce Leakage Current, Extract Maximum Power Point and Control Power
The main purposes of a transformerless grid-connected photovoltaic (PV) system consist of the reduction of leakage current, extraction of maximum power point (MPP), tracking of MPP (MPPT), controlling the active and reactive powers, and having the unity power factor. To achieve the above-mentioned aims, the following actions have been performed in this paper. First of all, a brief analysis of the transformerless PV system has been done by using the conventional full-bridge (FB) topologies with two bipolar and unipolar PWM techniques. Then, an effective solution has been also introduced to significantly reduce the leakage current in the conventional H5 FB topology. Moreover, a proper control method has been proposed by using the combination of the fractional opencircuit voltage (FOCV) and the model predictive control (MPC) strategies to extract the MPP from PV panels, control the injection of the reactive power to the gird and have the unity power factor. At last, the simulation results performed in PSCAD software will be used to prove the correct performance of the proposed control method in the improved H5 FB topology.