椎体间螺钉锁定钢板与跖骨解剖锁定钢板用于Lapidus关节融合术的比较:生物力学尸体研究

IF 1.8 Q2 ORTHOPEDICS
James M. Cottom, Joseph S Baker
{"title":"椎体间螺钉锁定钢板与跖骨解剖锁定钢板用于Lapidus关节融合术的比较:生物力学尸体研究","authors":"James M. Cottom, Joseph S Baker","doi":"10.1177/1938640016676341","DOIUrl":null,"url":null,"abstract":"Arthrodesis of the first metatarsal cuneiform joint, or Lapidus procedure, is a widely accepted treatment for hallux valgus. Recent studies have focused on comparing various constructs for this procedure both in the laboratory and clinical settings. The current study compared in a cadaveric model the strength of 2 constructs. The first construct utilized a medially applied low-profile locking plate and an interfragmentary screw directed from plantar-distal to dorsal-proximal. The second construct consisted of a plantarly applied plate with a compression screw placed through the plate from plantar-distal to dorsal-proximal. The ultimate load to failure for the 2 groups tested was 255.38 ± 155.38 N and 197.48 ± 108.61 N, respectively (P = .402). There was no significant difference found between the 2 groups with respect to ultimate load to failure, stiffness of the construct, or moment at time of failure. In conclusion, the medially applied plate with plantar interfragmentary screw appears to be stronger than the plantar Lapidus plate tested for first metatarsal cuneiform arthrodesis, though this difference did not reach statistical significance. Levels of Evidence: Level V: Biomechanical Study","PeriodicalId":39271,"journal":{"name":"Foot and Ankle Specialist","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1938640016676341","citationCount":"10","resultStr":"{\"title\":\"Comparison of Locking Plate with Interfragmentary Screw Versus Plantarly Applied Anatomic Locking Plate for Lapidus Arthrodesis: A Biomechanical Cadaveric Study\",\"authors\":\"James M. Cottom, Joseph S Baker\",\"doi\":\"10.1177/1938640016676341\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Arthrodesis of the first metatarsal cuneiform joint, or Lapidus procedure, is a widely accepted treatment for hallux valgus. Recent studies have focused on comparing various constructs for this procedure both in the laboratory and clinical settings. The current study compared in a cadaveric model the strength of 2 constructs. The first construct utilized a medially applied low-profile locking plate and an interfragmentary screw directed from plantar-distal to dorsal-proximal. The second construct consisted of a plantarly applied plate with a compression screw placed through the plate from plantar-distal to dorsal-proximal. The ultimate load to failure for the 2 groups tested was 255.38 ± 155.38 N and 197.48 ± 108.61 N, respectively (P = .402). There was no significant difference found between the 2 groups with respect to ultimate load to failure, stiffness of the construct, or moment at time of failure. In conclusion, the medially applied plate with plantar interfragmentary screw appears to be stronger than the plantar Lapidus plate tested for first metatarsal cuneiform arthrodesis, though this difference did not reach statistical significance. Levels of Evidence: Level V: Biomechanical Study\",\"PeriodicalId\":39271,\"journal\":{\"name\":\"Foot and Ankle Specialist\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2017-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1938640016676341\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Foot and Ankle Specialist\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1938640016676341\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot and Ankle Specialist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1938640016676341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 10

摘要

第一跖楔形关节融合术,或Lapidus手术,是一种广泛接受的治疗拇外翻的方法。最近的研究集中在比较实验室和临床设置中该程序的各种结构。目前的研究在尸体模型中比较了两种构念的强度。第一种结构采用内侧应用的低轮廓锁定钢板和从跖远端到背近端的骨折间螺钉。第二种构造包括一个跖骨钢板,通过钢板从跖骨远端到背侧近端放置一个加压螺钉。两组的极限失效负荷分别为255.38±155.38 N和197.48±108.61 N (P = .402)。两组之间在失效的极限载荷、结构刚度或失效时的力矩方面没有显著差异。综上所述,在第一跖楔形关节融合术中,内侧应用带足底碎片间螺钉钢板似乎比足底Lapidus钢板更坚固,尽管这种差异没有达到统计学意义。证据等级:V级:生物力学研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Locking Plate with Interfragmentary Screw Versus Plantarly Applied Anatomic Locking Plate for Lapidus Arthrodesis: A Biomechanical Cadaveric Study
Arthrodesis of the first metatarsal cuneiform joint, or Lapidus procedure, is a widely accepted treatment for hallux valgus. Recent studies have focused on comparing various constructs for this procedure both in the laboratory and clinical settings. The current study compared in a cadaveric model the strength of 2 constructs. The first construct utilized a medially applied low-profile locking plate and an interfragmentary screw directed from plantar-distal to dorsal-proximal. The second construct consisted of a plantarly applied plate with a compression screw placed through the plate from plantar-distal to dorsal-proximal. The ultimate load to failure for the 2 groups tested was 255.38 ± 155.38 N and 197.48 ± 108.61 N, respectively (P = .402). There was no significant difference found between the 2 groups with respect to ultimate load to failure, stiffness of the construct, or moment at time of failure. In conclusion, the medially applied plate with plantar interfragmentary screw appears to be stronger than the plantar Lapidus plate tested for first metatarsal cuneiform arthrodesis, though this difference did not reach statistical significance. Levels of Evidence: Level V: Biomechanical Study
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Foot and Ankle Specialist
Foot and Ankle Specialist Health Professions-Podiatry
CiteScore
3.10
自引率
0.00%
发文量
100
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信