听觉脑干植入物定位新方案

S. Veronese, M. Cambiaghi, A. Sbarbati
{"title":"听觉脑干植入物定位新方案","authors":"S. Veronese, M. Cambiaghi, A. Sbarbati","doi":"10.31579/2578-8868/203","DOIUrl":null,"url":null,"abstract":"Background: Surgery for applying the auditory brainstem implant is an otoneurosurgery that requires careful intraoperative monitoring to optimize the placement of the electrode paddle. This study aimed to validate a new method capable of increasing the accuracy of electrode array placement, reducing channel interaction, electrical artefacts, and saturation effects, and providing the largest number of electrodes that can be activated with the lowest possible electric charge. Materials and methods: Thirty-six subjects aged between 1.42 and 69.92 years were tested during surgery for auditory brainstem implantation. We recorded auditory electrical responses of the brainstem using the implant supplier's suggested stimulation protocol and the new protocol. Results: Saturations effects and electric artefacts were noticed respectively in 81.85% and 53.25% of recordings using implant supplier's method, while in 70.34% and 24.75% of recordings using the new method, with a percentage variation of 11.51% and 28.50%. Considering the amount of charge required to activate the electrodes, with the implant supplier's method an average charge of 14 nC was needed, while with the new protocol an average charge of 8 nC was necessary. Conclusions: The new method improves the coupling between the auditory brainstem implant and the surface of the cochlear nucleus.","PeriodicalId":73865,"journal":{"name":"Journal of neuroscience and neurological surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"New Protocol for Auditory Brainstem Implant Positioning\",\"authors\":\"S. Veronese, M. Cambiaghi, A. Sbarbati\",\"doi\":\"10.31579/2578-8868/203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Surgery for applying the auditory brainstem implant is an otoneurosurgery that requires careful intraoperative monitoring to optimize the placement of the electrode paddle. This study aimed to validate a new method capable of increasing the accuracy of electrode array placement, reducing channel interaction, electrical artefacts, and saturation effects, and providing the largest number of electrodes that can be activated with the lowest possible electric charge. Materials and methods: Thirty-six subjects aged between 1.42 and 69.92 years were tested during surgery for auditory brainstem implantation. We recorded auditory electrical responses of the brainstem using the implant supplier's suggested stimulation protocol and the new protocol. Results: Saturations effects and electric artefacts were noticed respectively in 81.85% and 53.25% of recordings using implant supplier's method, while in 70.34% and 24.75% of recordings using the new method, with a percentage variation of 11.51% and 28.50%. Considering the amount of charge required to activate the electrodes, with the implant supplier's method an average charge of 14 nC was needed, while with the new protocol an average charge of 8 nC was necessary. Conclusions: The new method improves the coupling between the auditory brainstem implant and the surface of the cochlear nucleus.\",\"PeriodicalId\":73865,\"journal\":{\"name\":\"Journal of neuroscience and neurological surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neuroscience and neurological surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31579/2578-8868/203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neuroscience and neurological surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31579/2578-8868/203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:应用听觉脑干植入物的手术是一种耳神经外科手术,需要仔细的术中监测以优化电极板的放置。这项研究旨在验证一种新方法,该方法能够提高电极阵列放置的准确性,减少通道相互作用、电伪影和饱和效应,并提供尽可能少的电荷激活的最大数量的电极。材料和方法:36名年龄在1.42至69.92岁之间的受试者在听觉脑干植入手术中接受了测试。我们使用植入物供应商建议的刺激方案和新方案记录了脑干的听觉电反应。结果:在使用植入物供应商方法的记录中,分别有81.85%和53.25%的记录出现饱和效应和电伪影,而在使用新方法的记录的记录中分别有70.34%和24.75%的记录出现,百分比变化分别为11.51%和28.50%。考虑到激活电极所需的电荷量,对于植入物供应商的方法,需要14nC的平均电荷,而对于新方案,需要8NC的平均电荷。结论:该方法改善了听性脑干植入物与耳蜗核表面的耦合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
New Protocol for Auditory Brainstem Implant Positioning
Background: Surgery for applying the auditory brainstem implant is an otoneurosurgery that requires careful intraoperative monitoring to optimize the placement of the electrode paddle. This study aimed to validate a new method capable of increasing the accuracy of electrode array placement, reducing channel interaction, electrical artefacts, and saturation effects, and providing the largest number of electrodes that can be activated with the lowest possible electric charge. Materials and methods: Thirty-six subjects aged between 1.42 and 69.92 years were tested during surgery for auditory brainstem implantation. We recorded auditory electrical responses of the brainstem using the implant supplier's suggested stimulation protocol and the new protocol. Results: Saturations effects and electric artefacts were noticed respectively in 81.85% and 53.25% of recordings using implant supplier's method, while in 70.34% and 24.75% of recordings using the new method, with a percentage variation of 11.51% and 28.50%. Considering the amount of charge required to activate the electrodes, with the implant supplier's method an average charge of 14 nC was needed, while with the new protocol an average charge of 8 nC was necessary. Conclusions: The new method improves the coupling between the auditory brainstem implant and the surface of the cochlear nucleus.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信