{"title":"乳房植入物输送用预润滑聚丙烯注射器","authors":"Hsiao-Hung Chaing, Chen-Ying Su, Hsiu-Peng Lin, Chiao-Pei Chen, Ting-Chu Yu, Hsu-Wei Fang","doi":"10.1115/1.4052122","DOIUrl":null,"url":null,"abstract":"\n Breast augmentation is a common aesthetic surgery, and there are two major surgical methods for breast implant delivery: the finger method and the plastic film method. There are advantages and disadvantages for each method, and we have developed a pre-lubricated polypropylene (PP) injector that might be the most suitable device for delivering breast implants. By covering the interior surface of the injector with the hydrophilic coating, the friction coefficient was significantly reduced when sliding a silicone sled against the pre-lubricated PP injector. In order to confirm the pre-lubricated PP injector would not damage the breast implant, fatigue testing was performed and the result showed the injector did not cause rupture or microleakage of the breast implant. In addition, the cell viability result demonstrated the pre-lubricated PP injector was biocompatible. In addition, the pre-lubricated PP injector provides a small incision site and stability during breast implant delivery. Our results provided evidence that the pre-lubricated PP injector is a smooth and safe method for breast implant delivery.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pre-Lubricated Polypropylene Injector for Breast Implant Delivery\",\"authors\":\"Hsiao-Hung Chaing, Chen-Ying Su, Hsiu-Peng Lin, Chiao-Pei Chen, Ting-Chu Yu, Hsu-Wei Fang\",\"doi\":\"10.1115/1.4052122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Breast augmentation is a common aesthetic surgery, and there are two major surgical methods for breast implant delivery: the finger method and the plastic film method. There are advantages and disadvantages for each method, and we have developed a pre-lubricated polypropylene (PP) injector that might be the most suitable device for delivering breast implants. By covering the interior surface of the injector with the hydrophilic coating, the friction coefficient was significantly reduced when sliding a silicone sled against the pre-lubricated PP injector. In order to confirm the pre-lubricated PP injector would not damage the breast implant, fatigue testing was performed and the result showed the injector did not cause rupture or microleakage of the breast implant. In addition, the cell viability result demonstrated the pre-lubricated PP injector was biocompatible. In addition, the pre-lubricated PP injector provides a small incision site and stability during breast implant delivery. Our results provided evidence that the pre-lubricated PP injector is a smooth and safe method for breast implant delivery.\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4052122\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4052122","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Pre-Lubricated Polypropylene Injector for Breast Implant Delivery
Breast augmentation is a common aesthetic surgery, and there are two major surgical methods for breast implant delivery: the finger method and the plastic film method. There are advantages and disadvantages for each method, and we have developed a pre-lubricated polypropylene (PP) injector that might be the most suitable device for delivering breast implants. By covering the interior surface of the injector with the hydrophilic coating, the friction coefficient was significantly reduced when sliding a silicone sled against the pre-lubricated PP injector. In order to confirm the pre-lubricated PP injector would not damage the breast implant, fatigue testing was performed and the result showed the injector did not cause rupture or microleakage of the breast implant. In addition, the cell viability result demonstrated the pre-lubricated PP injector was biocompatible. In addition, the pre-lubricated PP injector provides a small incision site and stability during breast implant delivery. Our results provided evidence that the pre-lubricated PP injector is a smooth and safe method for breast implant delivery.
期刊介绍:
The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.