聚l -赖氨酸/还原氧化石墨烯传感器检测化妆品中对羟基苯甲酸甲酯

D. Nguyen, Tran Thanh Tam Toan
{"title":"聚l -赖氨酸/还原氧化石墨烯传感器检测化妆品中对羟基苯甲酸甲酯","authors":"D. Nguyen, Tran Thanh Tam Toan","doi":"10.1149/2754-2726/ac8aa7","DOIUrl":null,"url":null,"abstract":"In this study, a PoL/RGO material was successfully synthesized and employed to modify the working electrode for determining MPB in medication products through voltammetric techniques. The structure of the nanocomposite was characterized by UV–vis and FT-IR spectrum and its application to the MPB electrochemical detection was tested by the CV and DPV techniques. In the result, the modified PoL-RGO/GCE electrode exhibited a superior response toward MPB by applying the DPV method, compares to using the bare GCE, with a limit of detection (LOD), a limit of quantification (LOQ) is 0.20 μM and 0.70 μM, respectively and the concentration ranging from 1 to 200 μM. In addition, the repeatability (RSD of 2.2, 1.6, 1.4 for 5, 50 and 100 μM MPB, respectively), and the reproducibility (RSD of 4.7%) of the technique were examined as well. This illustrates the performance of the electrochemical sensor was statistically investigated by the CV and DPV methods demonstrating accuracy comparable to other analytical methods as well as indicating that MPB can be determined in cosmetics with high recovery ranging from 97% to 104.3%.","PeriodicalId":72870,"journal":{"name":"ECS sensors plus","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Detection of Methylparaben in Cosmetics by Poly L–Lysine/Reduced Graphene Oxide-Based Sensor\",\"authors\":\"D. Nguyen, Tran Thanh Tam Toan\",\"doi\":\"10.1149/2754-2726/ac8aa7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, a PoL/RGO material was successfully synthesized and employed to modify the working electrode for determining MPB in medication products through voltammetric techniques. The structure of the nanocomposite was characterized by UV–vis and FT-IR spectrum and its application to the MPB electrochemical detection was tested by the CV and DPV techniques. In the result, the modified PoL-RGO/GCE electrode exhibited a superior response toward MPB by applying the DPV method, compares to using the bare GCE, with a limit of detection (LOD), a limit of quantification (LOQ) is 0.20 μM and 0.70 μM, respectively and the concentration ranging from 1 to 200 μM. In addition, the repeatability (RSD of 2.2, 1.6, 1.4 for 5, 50 and 100 μM MPB, respectively), and the reproducibility (RSD of 4.7%) of the technique were examined as well. This illustrates the performance of the electrochemical sensor was statistically investigated by the CV and DPV methods demonstrating accuracy comparable to other analytical methods as well as indicating that MPB can be determined in cosmetics with high recovery ranging from 97% to 104.3%.\",\"PeriodicalId\":72870,\"journal\":{\"name\":\"ECS sensors plus\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ECS sensors plus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1149/2754-2726/ac8aa7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS sensors plus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/2754-2726/ac8aa7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

在本研究中,成功合成了一种PoL/RGO材料,并将其用于修饰工作电极,通过伏安技术测定药物产品中的MPB。采用紫外可见光谱和傅里叶变换红外光谱对纳米复合材料的结构进行了表征,并利用CV和DPV技术对其在MPB电化学检测中的应用进行了测试。结果表明,DPV法修饰的PoL-RGO/GCE电极对MPB的响应优于裸GCE,检测限(LOD)和定量限(LOQ)分别为0.20 μM和0.70 μM,浓度范围为1 ~ 200 μM。此外,对该方法的重复性(在5、50和100 μM MPB条件下RSD分别为2.2、1.6和1.4)和重现性(RSD为4.7%)进行了检验。这表明,通过CV和DPV方法对电化学传感器的性能进行了统计调查,显示出与其他分析方法相当的准确性,并且表明可以在化妆品中检测MPB,回收率在97%至104.3%之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detection of Methylparaben in Cosmetics by Poly L–Lysine/Reduced Graphene Oxide-Based Sensor
In this study, a PoL/RGO material was successfully synthesized and employed to modify the working electrode for determining MPB in medication products through voltammetric techniques. The structure of the nanocomposite was characterized by UV–vis and FT-IR spectrum and its application to the MPB electrochemical detection was tested by the CV and DPV techniques. In the result, the modified PoL-RGO/GCE electrode exhibited a superior response toward MPB by applying the DPV method, compares to using the bare GCE, with a limit of detection (LOD), a limit of quantification (LOQ) is 0.20 μM and 0.70 μM, respectively and the concentration ranging from 1 to 200 μM. In addition, the repeatability (RSD of 2.2, 1.6, 1.4 for 5, 50 and 100 μM MPB, respectively), and the reproducibility (RSD of 4.7%) of the technique were examined as well. This illustrates the performance of the electrochemical sensor was statistically investigated by the CV and DPV methods demonstrating accuracy comparable to other analytical methods as well as indicating that MPB can be determined in cosmetics with high recovery ranging from 97% to 104.3%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信