清真市场肉鸡的电虫病规程

IF 1.2 4区 农林科学 Q3 AGRICULTURE, DAIRY & ANIMAL SCIENCE
Gustavo Henrique Joazeiro de Almeida, C. Komiyama, V. A. R. Castilho, R. G. Garcia, M. Burbarelli, Jacqueline Rosa de Souza, Erique Ferreira Porifio, Bruna de Souza Eberhart
{"title":"清真市场肉鸡的电虫病规程","authors":"Gustavo Henrique Joazeiro de Almeida, C. Komiyama, V. A. R. Castilho, R. G. Garcia, M. Burbarelli, Jacqueline Rosa de Souza, Erique Ferreira Porifio, Bruna de Souza Eberhart","doi":"10.1139/cjas-2021-0082","DOIUrl":null,"url":null,"abstract":"Abstract This study considered the parameters of the halal market to evaluate different protocols for broiler electronarcosis regarding time to return of consciousness, bleeding efficiency, and carcass and meat quality at a broiler slaughterhouse. One hundred and eighty-four 43-day-old male broilers of the Cobb® strain were used. The experimental design used was completely randomized with 46 broilers for each protocol. The protocols used 80 V and 600 Hz, 50 V and 1000 Hz, 60 V and 1000 Hz, and 70 V and 1000 Hz. Time to return of consciousness, bleeding efficiency, bruising, presence of broken bones in pectoral muscle, and meat quality were evaluated. Birds subjected to stunning by the 50 V and 1000 Hz protocol showed the shortest time to return of consciousness after electronarcosis, and high incidence of breast hemorrhage. Birds subjected to the 60 V and 1000 Hz protocol had a higher percentage of broken bones in the pectoralis minor. The 50 V and 1000 Hz electronarcosis protocol fits better to the halal market due to the shorter time to return of consciousness and improved bleeding efficiency. This study suggests new proposals for stunning protocols to serve the halal market. Résumé Cette étude a considéré les paramètres du marché halal afin d’évaluer différents protocoles d’électronarcose (ou étourdissement électrique) des poulets à griller en ce qui a trait au temps de retour à la conscience, l’efficacité de la saignée, et la qualité de la carcasse et de la viande dans un abattoir de poulets à griller. Cent quatre-vingt-quatre poulets à griller mâles âgés de 43 jours de race Cobb® ont été utilisés. Le design expérimental utilisé était complètement aléatoire avec 46 poulets à griller pour chaque protocole. Les protocoles utilisés : 80 V et 600 Hz; 50 V et 1000 Hz; 60 V et 1000 Hz; 70 V et 1000 Hz. Le temps pour le retour à la conscience, l’efficacité de la saignée, les contusions, la présence de fractures aux os dans le muscle pectoral, et la qualité de viande ont été évalués. Les poulets ayant subi le protocole 50 V/1000 Hz ont montré la plus courte durée du retour à la conscience après l’électronarcose, et la plus grande incidence d’hémorragie de la poitrine. Les poulets ayant subi le protocole 60 V et 1000 Hz avaient un plus grand pourcentage de fractures d’os dans le Pectoralis minor. Le protocole d’électronarcose 50 V et 1000 Hz convient mieux au marché halal puisqu’il a la plus courte durée du retour à la conscience, et la meilleure efficacité de la saignée. Cette étude suggère de nouvelles propositions en matière de protocoles d’étourdissement pour servir le marché halal. [Traduit par la Rédaction]","PeriodicalId":9512,"journal":{"name":"Canadian Journal of Animal Science","volume":"102 1","pages":"440 - 447"},"PeriodicalIF":1.2000,"publicationDate":"2022-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electronarcosis protocols in broiler chickens for the halal market\",\"authors\":\"Gustavo Henrique Joazeiro de Almeida, C. Komiyama, V. A. R. Castilho, R. G. Garcia, M. Burbarelli, Jacqueline Rosa de Souza, Erique Ferreira Porifio, Bruna de Souza Eberhart\",\"doi\":\"10.1139/cjas-2021-0082\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This study considered the parameters of the halal market to evaluate different protocols for broiler electronarcosis regarding time to return of consciousness, bleeding efficiency, and carcass and meat quality at a broiler slaughterhouse. One hundred and eighty-four 43-day-old male broilers of the Cobb® strain were used. The experimental design used was completely randomized with 46 broilers for each protocol. The protocols used 80 V and 600 Hz, 50 V and 1000 Hz, 60 V and 1000 Hz, and 70 V and 1000 Hz. Time to return of consciousness, bleeding efficiency, bruising, presence of broken bones in pectoral muscle, and meat quality were evaluated. Birds subjected to stunning by the 50 V and 1000 Hz protocol showed the shortest time to return of consciousness after electronarcosis, and high incidence of breast hemorrhage. Birds subjected to the 60 V and 1000 Hz protocol had a higher percentage of broken bones in the pectoralis minor. The 50 V and 1000 Hz electronarcosis protocol fits better to the halal market due to the shorter time to return of consciousness and improved bleeding efficiency. This study suggests new proposals for stunning protocols to serve the halal market. Résumé Cette étude a considéré les paramètres du marché halal afin d’évaluer différents protocoles d’électronarcose (ou étourdissement électrique) des poulets à griller en ce qui a trait au temps de retour à la conscience, l’efficacité de la saignée, et la qualité de la carcasse et de la viande dans un abattoir de poulets à griller. Cent quatre-vingt-quatre poulets à griller mâles âgés de 43 jours de race Cobb® ont été utilisés. Le design expérimental utilisé était complètement aléatoire avec 46 poulets à griller pour chaque protocole. Les protocoles utilisés : 80 V et 600 Hz; 50 V et 1000 Hz; 60 V et 1000 Hz; 70 V et 1000 Hz. Le temps pour le retour à la conscience, l’efficacité de la saignée, les contusions, la présence de fractures aux os dans le muscle pectoral, et la qualité de viande ont été évalués. Les poulets ayant subi le protocole 50 V/1000 Hz ont montré la plus courte durée du retour à la conscience après l’électronarcose, et la plus grande incidence d’hémorragie de la poitrine. Les poulets ayant subi le protocole 60 V et 1000 Hz avaient un plus grand pourcentage de fractures d’os dans le Pectoralis minor. Le protocole d’électronarcose 50 V et 1000 Hz convient mieux au marché halal puisqu’il a la plus courte durée du retour à la conscience, et la meilleure efficacité de la saignée. Cette étude suggère de nouvelles propositions en matière de protocoles d’étourdissement pour servir le marché halal. [Traduit par la Rédaction]\",\"PeriodicalId\":9512,\"journal\":{\"name\":\"Canadian Journal of Animal Science\",\"volume\":\"102 1\",\"pages\":\"440 - 447\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Journal of Animal Science\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1139/cjas-2021-0082\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"AGRICULTURE, DAIRY & ANIMAL SCIENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Animal Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1139/cjas-2021-0082","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AGRICULTURE, DAIRY & ANIMAL SCIENCE","Score":null,"Total":0}
引用次数: 0

摘要

摘要本研究考虑了清真市场的参数,以评估肉鸡屠宰场意识、出血效率、尸体和肉类质量恢复时间的不同肉鸡电子中毒协议。一百八十四43天-科布的老雄性肉鸡® 使用了Strain。使用的实验设计完全随机,每个协议有46个研磨机。协议使用80V和600Hz、50V和1000Hz、60V和1000Hz以及70V和1000Hz。评估了恢复意识、出血效率、布鲁森、胸肌骨折和肉类质量的时间。受50V和1000Hz协议影响的鸟类显示,电麻醉后恢复意识的时间最短,乳腺出血发生率高。受60 V和1000 Hz协议约束的鸟类胸肌小骨骨折比例较高。50V和1000Hz电子麻醉协议更适合清真市场,因为恢复意识和提高出血效率的时间更短。这项研究提出了服务于清真市场的令人惊叹的协议的新建议。摘要:本研究考虑了清真市场参数,以评估肉鸡在恢复意识时间、出血效率以及肉鸡屠宰场的胴体和肉质量方面的不同电麻醉(或电击)方案。Cobb品种的184只43日龄雄性肉鸡® 已被使用。所使用的实验设计是完全随机的,每个方案有46只肉鸡。使用的协议:80V和600Hz;50V和1000Hz;60V和1000Hz;70V和1000Hz。评估了恢复意识的时间、出血的有效性、瘀伤、胸肌骨折的存在以及肉类质量。接受50V/1000Hz方案的鸡在电麻醉后恢复意识的时间最短,胸部出血的发生率最高。接受60V和1000Hz方案的鸡胸肌小骨折的比例更高。50 V和1000 Hz的电子麻醉协议更适合清真市场,因为它具有最短的恢复意识时间和最佳的出血效率。这项研究提出了服务于清真市场的令人惊叹的协议的新建议。[由编辑翻译]
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electronarcosis protocols in broiler chickens for the halal market
Abstract This study considered the parameters of the halal market to evaluate different protocols for broiler electronarcosis regarding time to return of consciousness, bleeding efficiency, and carcass and meat quality at a broiler slaughterhouse. One hundred and eighty-four 43-day-old male broilers of the Cobb® strain were used. The experimental design used was completely randomized with 46 broilers for each protocol. The protocols used 80 V and 600 Hz, 50 V and 1000 Hz, 60 V and 1000 Hz, and 70 V and 1000 Hz. Time to return of consciousness, bleeding efficiency, bruising, presence of broken bones in pectoral muscle, and meat quality were evaluated. Birds subjected to stunning by the 50 V and 1000 Hz protocol showed the shortest time to return of consciousness after electronarcosis, and high incidence of breast hemorrhage. Birds subjected to the 60 V and 1000 Hz protocol had a higher percentage of broken bones in the pectoralis minor. The 50 V and 1000 Hz electronarcosis protocol fits better to the halal market due to the shorter time to return of consciousness and improved bleeding efficiency. This study suggests new proposals for stunning protocols to serve the halal market. Résumé Cette étude a considéré les paramètres du marché halal afin d’évaluer différents protocoles d’électronarcose (ou étourdissement électrique) des poulets à griller en ce qui a trait au temps de retour à la conscience, l’efficacité de la saignée, et la qualité de la carcasse et de la viande dans un abattoir de poulets à griller. Cent quatre-vingt-quatre poulets à griller mâles âgés de 43 jours de race Cobb® ont été utilisés. Le design expérimental utilisé était complètement aléatoire avec 46 poulets à griller pour chaque protocole. Les protocoles utilisés : 80 V et 600 Hz; 50 V et 1000 Hz; 60 V et 1000 Hz; 70 V et 1000 Hz. Le temps pour le retour à la conscience, l’efficacité de la saignée, les contusions, la présence de fractures aux os dans le muscle pectoral, et la qualité de viande ont été évalués. Les poulets ayant subi le protocole 50 V/1000 Hz ont montré la plus courte durée du retour à la conscience après l’électronarcose, et la plus grande incidence d’hémorragie de la poitrine. Les poulets ayant subi le protocole 60 V et 1000 Hz avaient un plus grand pourcentage de fractures d’os dans le Pectoralis minor. Le protocole d’électronarcose 50 V et 1000 Hz convient mieux au marché halal puisqu’il a la plus courte durée du retour à la conscience, et la meilleure efficacité de la saignée. Cette étude suggère de nouvelles propositions en matière de protocoles d’étourdissement pour servir le marché halal. [Traduit par la Rédaction]
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Canadian Journal of Animal Science
Canadian Journal of Animal Science 农林科学-奶制品与动物科学
CiteScore
2.30
自引率
0.00%
发文量
51
审稿时长
6 months
期刊介绍: Published since 1957, this quarterly journal contains new research on all aspects of animal agriculture and animal products, including breeding and genetics; cellular and molecular biology; growth and development; meat science; modelling animal systems; physiology and endocrinology; ruminant nutrition; non-ruminant nutrition; and welfare, behaviour, and management. It also publishes reviews, letters to the editor, abstracts of technical papers presented at the annual meeting of the Canadian Society of Animal Science, and occasionally conference proceedings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信