{"title":"滤料粒径和加载速率对快速砂滤去除微塑料过滤性能的影响","authors":"Mutiara Fajar, Emenda Sembiring, M. Handajani","doi":"10.5614/j.eng.technol.sci.2022.54.5.12","DOIUrl":null,"url":null,"abstract":"Microplastics (MP) can pose a serious threat to the environment and human health because of their tiny size and ability to spread easily in water. One of the alternative treatments to remove MP from water is the rapid sand filter (RSF). The objective of this study was to analyze the effects of filter media size and loading rate on RSF performance in removing MP. The applied filter media was silica sand with effective sizes (ES) of 0.39 and 0.68 mm. The loading rates of filtration were 4; 6; 8 and 10 m3/m2-h. The MP samples were made from plastic bags and torn tires (artificial samples: 10 to 800 µm). This study showed that the MP removal percentage was up to 96.6% (MP size larger than 200 µm). The head loss increment for loading rates 4; 6; 8; 10 m3/m2-h was 0.16; 0.35; 0.34; 0.25 m (ES 0.39 m) and 0.10; 0.18; 0.18; 0.19 m (ES 0.68 m)), respectively. Meanwhile, the filtration cycle for loading rates 4; 6; 8; and 10 m3/m2-h was 5, 2, 2, and 1 days (ES 0.39 mm) and 9, 4, 3, and 3 days (ES 0.68 mm), respectively. The result of this study showed that the smaller the filter media size, the higher the head loss of the filter media bed. Furthermore, there is an increased head loss of the filter media bed when the loading rate is greater.","PeriodicalId":15689,"journal":{"name":"Journal of Engineering and Technological Sciences","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2022-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Effect of Filter Media Size and Loading Rate to Filter Performance of Removing Microplastics using Rapid Sand Filter\",\"authors\":\"Mutiara Fajar, Emenda Sembiring, M. Handajani\",\"doi\":\"10.5614/j.eng.technol.sci.2022.54.5.12\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Microplastics (MP) can pose a serious threat to the environment and human health because of their tiny size and ability to spread easily in water. One of the alternative treatments to remove MP from water is the rapid sand filter (RSF). The objective of this study was to analyze the effects of filter media size and loading rate on RSF performance in removing MP. The applied filter media was silica sand with effective sizes (ES) of 0.39 and 0.68 mm. The loading rates of filtration were 4; 6; 8 and 10 m3/m2-h. The MP samples were made from plastic bags and torn tires (artificial samples: 10 to 800 µm). This study showed that the MP removal percentage was up to 96.6% (MP size larger than 200 µm). The head loss increment for loading rates 4; 6; 8; 10 m3/m2-h was 0.16; 0.35; 0.34; 0.25 m (ES 0.39 m) and 0.10; 0.18; 0.18; 0.19 m (ES 0.68 m)), respectively. Meanwhile, the filtration cycle for loading rates 4; 6; 8; and 10 m3/m2-h was 5, 2, 2, and 1 days (ES 0.39 mm) and 9, 4, 3, and 3 days (ES 0.68 mm), respectively. The result of this study showed that the smaller the filter media size, the higher the head loss of the filter media bed. Furthermore, there is an increased head loss of the filter media bed when the loading rate is greater.\",\"PeriodicalId\":15689,\"journal\":{\"name\":\"Journal of Engineering and Technological Sciences\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2022-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Engineering and Technological Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5614/j.eng.technol.sci.2022.54.5.12\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering and Technological Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5614/j.eng.technol.sci.2022.54.5.12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

摘要

微塑料(MP)由于其微小的尺寸和易于在水中扩散的能力,可能对环境和人类健康构成严重威胁。从水中去除MP的替代处理之一是快速砂滤(RSF)。本研究的目的是分析滤料尺寸和加载速率对RSF去除MP性能的影响。过滤介质为硅砂,有效粒径(ES)分别为0.39和0.68 mm。过滤负荷率为4;6;8和10 m3/m2-h。MP样品由塑料袋和撕裂轮胎制成(人工样品:10 ~ 800µm)。实验结果表明,MP去除率高达96.6% (MP粒径大于200µm)。加载速率为4时水头损失增量;6;8;10 m3/m2-h = 0.16;0.35;0.34;0.25 m (ES 0.39 m)和0.10;0.18;0.18;0.19 m (ES 0.68 m))。同时,过滤周期为加载速率4;6;8;10 m3/m2-h分别为5、2、2和1天(ES 0.39 mm)和9、4、3和3天(ES 0.68 mm)。研究结果表明,滤料粒径越小,滤料床的水头损失越大。此外,当负载率较大时,滤料床的水头损失增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Filter Media Size and Loading Rate to Filter Performance of Removing Microplastics using Rapid Sand Filter
Microplastics (MP) can pose a serious threat to the environment and human health because of their tiny size and ability to spread easily in water. One of the alternative treatments to remove MP from water is the rapid sand filter (RSF). The objective of this study was to analyze the effects of filter media size and loading rate on RSF performance in removing MP. The applied filter media was silica sand with effective sizes (ES) of 0.39 and 0.68 mm. The loading rates of filtration were 4; 6; 8 and 10 m3/m2-h. The MP samples were made from plastic bags and torn tires (artificial samples: 10 to 800 µm). This study showed that the MP removal percentage was up to 96.6% (MP size larger than 200 µm). The head loss increment for loading rates 4; 6; 8; 10 m3/m2-h was 0.16; 0.35; 0.34; 0.25 m (ES 0.39 m) and 0.10; 0.18; 0.18; 0.19 m (ES 0.68 m)), respectively. Meanwhile, the filtration cycle for loading rates 4; 6; 8; and 10 m3/m2-h was 5, 2, 2, and 1 days (ES 0.39 mm) and 9, 4, 3, and 3 days (ES 0.68 mm), respectively. The result of this study showed that the smaller the filter media size, the higher the head loss of the filter media bed. Furthermore, there is an increased head loss of the filter media bed when the loading rate is greater.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Engineering and Technological Sciences
Journal of Engineering and Technological Sciences ENGINEERING, MULTIDISCIPLINARY-
CiteScore
2.30
自引率
11.10%
发文量
77
审稿时长
24 weeks
期刊介绍: Journal of Engineering and Technological Sciences welcomes full research articles in the area of Engineering Sciences from the following subject areas: Aerospace Engineering, Biotechnology, Chemical Engineering, Civil Engineering, Electrical Engineering, Engineering Physics, Environmental Engineering, Industrial Engineering, Information Engineering, Mechanical Engineering, Material Science and Engineering, Manufacturing Processes, Microelectronics, Mining Engineering, Petroleum Engineering, and other application of physical, biological, chemical and mathematical sciences in engineering. Authors are invited to submit articles that have not been published previously and are not under consideration elsewhere.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信