两种仪器技术对VDW的影响。旋转器械对碎片和冲洗物根尖挤压的体外研究

IF 0.2 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Seda Falakaloğlu, Merve Yeniçeri Özata, E. Iriboz
{"title":"两种仪器技术对VDW的影响。旋转器械对碎片和冲洗物根尖挤压的体外研究","authors":"Seda Falakaloğlu, Merve Yeniçeri Özata, E. Iriboz","doi":"10.14693/jdi.v29i1.1299","DOIUrl":null,"url":null,"abstract":"Objectives: This study compared the amount of apically extruded debris and irrigant using VDW.ROTATE instruments with different kinematics (continuous rotation and reciprocation motion) and the ProTaper Gold system. Methods: Sixty extracted mandibular premolar teeth were selected. The teeth were prepared for the agar gel model. The roots were randomly divided into three groups (n=20). In two groups, the root canals were instrumented using the following movement kinematics: VDW.ROTATE reciprocation motion and continuous rotation. In the other group, root canals were prepared with ProTaper Gold. Apically extruded debris and irrigant during instrumentation were collected into preweighed Eppendorf tubes and were assessed with an electronic balance. All procedures were performed in a 35oC hot water bath. The data were analyzed using the Shapiro–Wilk and Kruskal–Wallis tests at a 5% significance level. Results: ROTATE-Reciprocation extruded the least amount of debris, but this finding was not significant when compared with the amount of debris and irrigant extruded by the ProTaper Gold and ROTATE-Rotation (p>.05). Conclusion: All instrumentation kinematics were associated with apical debris and irrigant extrusion. Movement kinematics did not affect the amount of apically extruded debris and irrigants when using VDW.ROTATE instruments.","PeriodicalId":53873,"journal":{"name":"Journal of Dentistry Indonesia","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2022-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effects of Two Instrumentation Techniques for VDW.Rotate Instruments on the Apical Extrusion of Debris and Irrigants: An In Vitro Study\",\"authors\":\"Seda Falakaloğlu, Merve Yeniçeri Özata, E. Iriboz\",\"doi\":\"10.14693/jdi.v29i1.1299\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives: This study compared the amount of apically extruded debris and irrigant using VDW.ROTATE instruments with different kinematics (continuous rotation and reciprocation motion) and the ProTaper Gold system. Methods: Sixty extracted mandibular premolar teeth were selected. The teeth were prepared for the agar gel model. The roots were randomly divided into three groups (n=20). In two groups, the root canals were instrumented using the following movement kinematics: VDW.ROTATE reciprocation motion and continuous rotation. In the other group, root canals were prepared with ProTaper Gold. Apically extruded debris and irrigant during instrumentation were collected into preweighed Eppendorf tubes and were assessed with an electronic balance. All procedures were performed in a 35oC hot water bath. The data were analyzed using the Shapiro–Wilk and Kruskal–Wallis tests at a 5% significance level. Results: ROTATE-Reciprocation extruded the least amount of debris, but this finding was not significant when compared with the amount of debris and irrigant extruded by the ProTaper Gold and ROTATE-Rotation (p>.05). Conclusion: All instrumentation kinematics were associated with apical debris and irrigant extrusion. Movement kinematics did not affect the amount of apically extruded debris and irrigants when using VDW.ROTATE instruments.\",\"PeriodicalId\":53873,\"journal\":{\"name\":\"Journal of Dentistry Indonesia\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dentistry Indonesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14693/jdi.v29i1.1299\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14693/jdi.v29i1.1299","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究比较了VDW的根尖挤压碎片和冲洗量。旋转不同运动(连续旋转和往复运动)的仪器和ProTaper Gold系统。方法:选择拔除的下颌前磨牙60颗。制备琼脂凝胶牙模型。根随机分为3组(n=20)。在两组中,使用以下运动运动学对根管进行固定:VDW。旋转往复运动,连续旋转。另一组用ProTaper Gold预备根管。在仪器过程中,将根尖挤压的碎片和冲洗物收集到预称重的埃彭多夫管中,并用电子天平进行评估。所有手术均在35℃热水浴中进行。使用Shapiro-Wilk和Kruskal-Wallis检验在5%显著性水平上分析数据。结果:ROTATE-Reciprocation挤出的碎屑最少,但与ProTaper Gold和ROTATE-Rotation挤出的碎屑和冲洗液相比,这一发现并不显著(p>.05)。结论:所有的内固定运动都与根尖碎片和冲洗挤压有关。当使用VDW时,运动运动学不影响根尖挤压碎片和冲洗物的数量。旋转工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effects of Two Instrumentation Techniques for VDW.Rotate Instruments on the Apical Extrusion of Debris and Irrigants: An In Vitro Study
Objectives: This study compared the amount of apically extruded debris and irrigant using VDW.ROTATE instruments with different kinematics (continuous rotation and reciprocation motion) and the ProTaper Gold system. Methods: Sixty extracted mandibular premolar teeth were selected. The teeth were prepared for the agar gel model. The roots were randomly divided into three groups (n=20). In two groups, the root canals were instrumented using the following movement kinematics: VDW.ROTATE reciprocation motion and continuous rotation. In the other group, root canals were prepared with ProTaper Gold. Apically extruded debris and irrigant during instrumentation were collected into preweighed Eppendorf tubes and were assessed with an electronic balance. All procedures were performed in a 35oC hot water bath. The data were analyzed using the Shapiro–Wilk and Kruskal–Wallis tests at a 5% significance level. Results: ROTATE-Reciprocation extruded the least amount of debris, but this finding was not significant when compared with the amount of debris and irrigant extruded by the ProTaper Gold and ROTATE-Rotation (p>.05). Conclusion: All instrumentation kinematics were associated with apical debris and irrigant extrusion. Movement kinematics did not affect the amount of apically extruded debris and irrigants when using VDW.ROTATE instruments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Dentistry Indonesia
Journal of Dentistry Indonesia DENTISTRY, ORAL SURGERY & MEDICINE-
自引率
0.00%
发文量
11
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信