{"title":"超声心动图参数鉴别完全性房室间隔缺损平衡型和不平衡型","authors":"Z. Vassileva, A. Kaneva","doi":"10.3897/bgcardio.28.e81005","DOIUrl":null,"url":null,"abstract":"The diagnosis of complete atrioventricular septal defect (CAVSD) relies completely on echocardiography. Different measurements can be used for the differentiation of the balanced from the unbalanced forms of the defect but each of them has limitations and cannot be applied separately. There is no established algorithm ensuring precise classifi cation of the CAVSD as balanced or unbalanced, especially in borderline forms. Based on a protocol, including measurements of a series of echocardiographic parameters used by other investigators, we have managed to identify 4 measurements which when applied in a predictive model allow for correct determination of the form of the CAVSD in 97% of the cases. These parameters are: infl ow angle right ventricle/left ventricle, left atrioventricular valve infl ow, atrioventricular valve index, and ratio between the long axes of the two ventricles.","PeriodicalId":33976,"journal":{"name":"B''lgarska kardiologiia","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Echocardiographic parameters for differentiation of balanced from unbalanced forms of complete atrioventricular septal defect\",\"authors\":\"Z. Vassileva, A. Kaneva\",\"doi\":\"10.3897/bgcardio.28.e81005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The diagnosis of complete atrioventricular septal defect (CAVSD) relies completely on echocardiography. Different measurements can be used for the differentiation of the balanced from the unbalanced forms of the defect but each of them has limitations and cannot be applied separately. There is no established algorithm ensuring precise classifi cation of the CAVSD as balanced or unbalanced, especially in borderline forms. Based on a protocol, including measurements of a series of echocardiographic parameters used by other investigators, we have managed to identify 4 measurements which when applied in a predictive model allow for correct determination of the form of the CAVSD in 97% of the cases. These parameters are: infl ow angle right ventricle/left ventricle, left atrioventricular valve infl ow, atrioventricular valve index, and ratio between the long axes of the two ventricles.\",\"PeriodicalId\":33976,\"journal\":{\"name\":\"B''lgarska kardiologiia\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"B''lgarska kardiologiia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3897/bgcardio.28.e81005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"B''lgarska kardiologiia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3897/bgcardio.28.e81005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

完全性房室间隔缺损的诊断完全依赖于超声心动图。不同的测量可以用于区分缺陷的平衡形式和不平衡形式,但每种测量都有局限性,不能单独应用。目前还没有确定的算法可以确保将CAVSD精确分类为平衡或不平衡,尤其是在边界形式下。根据一项协议,包括其他研究人员使用的一系列超声心动图参数的测量,我们已经成功确定了4项测量,当将其应用于预测模型时,97%的病例可以正确确定CAVSD的形式。这些参数是:右心室/左心室的角度、左房室瓣的角度、房室瓣指数和两个心室长轴之间的比率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Echocardiographic parameters for differentiation of balanced from unbalanced forms of complete atrioventricular septal defect
The diagnosis of complete atrioventricular septal defect (CAVSD) relies completely on echocardiography. Different measurements can be used for the differentiation of the balanced from the unbalanced forms of the defect but each of them has limitations and cannot be applied separately. There is no established algorithm ensuring precise classifi cation of the CAVSD as balanced or unbalanced, especially in borderline forms. Based on a protocol, including measurements of a series of echocardiographic parameters used by other investigators, we have managed to identify 4 measurements which when applied in a predictive model allow for correct determination of the form of the CAVSD in 97% of the cases. These parameters are: infl ow angle right ventricle/left ventricle, left atrioventricular valve infl ow, atrioventricular valve index, and ratio between the long axes of the two ventricles.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
40
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信