骶髂关节活动的三维运动分析:可靠性研究

IF 0.4 4区 医学 Q3 MEDICINE, GENERAL & INTERNAL
Ahmad Bahramian Parchekouhi, N. Karimi, Mohammad Yousefi, F. T. Ghomsheh, L. Rahnama
{"title":"骶髂关节活动的三维运动分析:可靠性研究","authors":"Ahmad Bahramian Parchekouhi, N. Karimi, Mohammad Yousefi, F. T. Ghomsheh, L. Rahnama","doi":"10.32592/ircmj.2023.25.1.2440","DOIUrl":null,"url":null,"abstract":"Background: Sacroiliac joint (SIJ) movement has been investigated in many studies using a motion analysis system; however, the reliability of this method has not been well defined yet.\n\nObjectives: This study aimed to investigate the reliability of measuring the three-dimensional (3D) movement of the SIJ through the motion analysis system.\n\nMethods: A total of 10 healthy participants performed three forward flexions from a standing position twice in one session with an interval of 30 minutes. The movements were captured by the VICON motion analysis system, and the motion of the sacrum relative to each innominate was estimated in three plans of movement. The test-retest reliability was calculated with the average of three trials using the intraclass correlation coefficient (ICC) with a 95% confidence interval (CI).\n\nResults: The measurements demonstrated good to excellent reliability (ICC: from 0.61 to 0.97) that was achieved for the SIJ motion variables.\n\nConclusion: The outcomes of this study showed that the 3D motion analysis can be used for the evaluation of SIJ mobility due to its acceptable reliability.","PeriodicalId":48912,"journal":{"name":"Iranian Red Crescent Medical Journal","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2023-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-dimensional Motion Analysis of Sacroiliac Joint Mobility: A Reliability Study\",\"authors\":\"Ahmad Bahramian Parchekouhi, N. Karimi, Mohammad Yousefi, F. T. Ghomsheh, L. Rahnama\",\"doi\":\"10.32592/ircmj.2023.25.1.2440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Sacroiliac joint (SIJ) movement has been investigated in many studies using a motion analysis system; however, the reliability of this method has not been well defined yet.\\n\\nObjectives: This study aimed to investigate the reliability of measuring the three-dimensional (3D) movement of the SIJ through the motion analysis system.\\n\\nMethods: A total of 10 healthy participants performed three forward flexions from a standing position twice in one session with an interval of 30 minutes. The movements were captured by the VICON motion analysis system, and the motion of the sacrum relative to each innominate was estimated in three plans of movement. The test-retest reliability was calculated with the average of three trials using the intraclass correlation coefficient (ICC) with a 95% confidence interval (CI).\\n\\nResults: The measurements demonstrated good to excellent reliability (ICC: from 0.61 to 0.97) that was achieved for the SIJ motion variables.\\n\\nConclusion: The outcomes of this study showed that the 3D motion analysis can be used for the evaluation of SIJ mobility due to its acceptable reliability.\",\"PeriodicalId\":48912,\"journal\":{\"name\":\"Iranian Red Crescent Medical Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2023-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Red Crescent Medical Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.32592/ircmj.2023.25.1.2440\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Red Crescent Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.32592/ircmj.2023.25.1.2440","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:骶髂关节(SIJ)的运动已经在许多研究中使用运动分析系统进行了研究;然而,这种方法的可靠性尚未得到很好的定义。目的:本研究旨在探讨通过运动分析系统测量SIJ三维运动的可靠性。方法:共有10名健康参与者在一次会话中两次从站立位置进行3次前屈,间隔30分钟。这些运动被VICON运动分析系统捕获,并在三种运动方案中估计骶骨相对于每个无名物的运动。用类内相关系数(ICC)和95%置信区间(CI)计算三次试验的平均重测信度。结果:测量结果表明,SIJ运动变量具有良好到极好的可靠性(ICC:从0.61到0.97)。结论:本研究结果表明,三维运动分析可用于SIJ灵活性的评估,其可靠性可接受。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three-dimensional Motion Analysis of Sacroiliac Joint Mobility: A Reliability Study
Background: Sacroiliac joint (SIJ) movement has been investigated in many studies using a motion analysis system; however, the reliability of this method has not been well defined yet. Objectives: This study aimed to investigate the reliability of measuring the three-dimensional (3D) movement of the SIJ through the motion analysis system. Methods: A total of 10 healthy participants performed three forward flexions from a standing position twice in one session with an interval of 30 minutes. The movements were captured by the VICON motion analysis system, and the motion of the sacrum relative to each innominate was estimated in three plans of movement. The test-retest reliability was calculated with the average of three trials using the intraclass correlation coefficient (ICC) with a 95% confidence interval (CI). Results: The measurements demonstrated good to excellent reliability (ICC: from 0.61 to 0.97) that was achieved for the SIJ motion variables. Conclusion: The outcomes of this study showed that the 3D motion analysis can be used for the evaluation of SIJ mobility due to its acceptable reliability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iranian Red Crescent Medical Journal
Iranian Red Crescent Medical Journal MEDICINE, GENERAL & INTERNAL-
CiteScore
1.16
自引率
0.00%
发文量
0
期刊介绍: The IRANIAN RED CRESCENT MEDICAL JOURNAL is an international, English language, peer-reviewed journal dealing with general Medicine and Surgery, Disaster Medicine and Health Policy. It is an official Journal of the Iranian Hospital Dubai and is published monthly. The Iranian Red Crescent Medical Journal aims at publishing the high quality materials, both clinical and scientific, on all aspects of Medicine and Surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信