Vijaya Anandan, Rekha Srinivasan, R. Asokan, R. George
{"title":"使用Pentacam和前段光学相干断层扫描评估正常人前房容积","authors":"Vijaya Anandan, Rekha Srinivasan, R. Asokan, R. George","doi":"10.35119/asjoo.v16i2.367","DOIUrl":null,"url":null,"abstract":"Aim: To compare the anterior chamber volume measurements obtained with Pentacam and derived from anterior segment optical coherence tomography. \nDesign: Cross-sectional study. \nMethods: We included normal subjects who underwent a comprehensive eye examination including refraction, keratometry, Goldmann applanation tonometry, gonioscopy, anterior segment optical coherence tomography (AS-OCT) (Carl Zeiss Meditec Inc.; Dublin, CA, USA) and Pentacam (Oculus Inc.; Lynnwood, WA, USA). Fifty scans were selected for Pentacam and 12 images were selected for calculation of anterior chamber volume. Only the right eye was considered for analysis. \nResults: One-hundred and nineteen eyes of 119 subjects were included for analysis. The mean age of the subjects was 42.58 ± 13.15 years, of which 74 were female and 45 were male. The mean anterior chamber volume measured using AS-OCT was 119.17 ± 26.56 mm3 and with Pentacam was 131.29 ± 34.26 mm3. The comparison of means between the two modalities was statistically significant (t = -8.857, Mean Difference (MD) = 12.11, 95% CI: (4.29, 19.95), p = 0.003). Bland-Altman plot showed poor agreement between the chamber volume measurements obtained by Pentacam and AS-OCT with MD of 12.1 mm3 (95 % CI: 41.4 to -17.1) and intra-class correlation between the two instruments was 0.94 (95% CI: 0.91, 0.96) (p < 0.0001). \nConclusion: The anterior chamber volume can be measured using Pentacam as well as AS-OCT since these measurements were reliable. However, these measurements were not interchangeable due to poor levels of agreement.","PeriodicalId":39864,"journal":{"name":"Asian Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of anterior chamber volume using Pentacam and anterior segment optical coherence tomography among normal subjects\",\"authors\":\"Vijaya Anandan, Rekha Srinivasan, R. Asokan, R. George\",\"doi\":\"10.35119/asjoo.v16i2.367\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: To compare the anterior chamber volume measurements obtained with Pentacam and derived from anterior segment optical coherence tomography. \\nDesign: Cross-sectional study. \\nMethods: We included normal subjects who underwent a comprehensive eye examination including refraction, keratometry, Goldmann applanation tonometry, gonioscopy, anterior segment optical coherence tomography (AS-OCT) (Carl Zeiss Meditec Inc.; Dublin, CA, USA) and Pentacam (Oculus Inc.; Lynnwood, WA, USA). Fifty scans were selected for Pentacam and 12 images were selected for calculation of anterior chamber volume. Only the right eye was considered for analysis. \\nResults: One-hundred and nineteen eyes of 119 subjects were included for analysis. The mean age of the subjects was 42.58 ± 13.15 years, of which 74 were female and 45 were male. The mean anterior chamber volume measured using AS-OCT was 119.17 ± 26.56 mm3 and with Pentacam was 131.29 ± 34.26 mm3. The comparison of means between the two modalities was statistically significant (t = -8.857, Mean Difference (MD) = 12.11, 95% CI: (4.29, 19.95), p = 0.003). Bland-Altman plot showed poor agreement between the chamber volume measurements obtained by Pentacam and AS-OCT with MD of 12.1 mm3 (95 % CI: 41.4 to -17.1) and intra-class correlation between the two instruments was 0.94 (95% CI: 0.91, 0.96) (p < 0.0001). \\nConclusion: The anterior chamber volume can be measured using Pentacam as well as AS-OCT since these measurements were reliable. However, these measurements were not interchangeable due to poor levels of agreement.\",\"PeriodicalId\":39864,\"journal\":{\"name\":\"Asian Journal of Ophthalmology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35119/asjoo.v16i2.367\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35119/asjoo.v16i2.367","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较Pentacam和前房光学相干断层扫描的前房容积测量结果。设计:横断面研究。方法:我们纳入了接受全面眼科检查的正常受试者,包括屈光、角膜测量、Goldmann屈光眼压、角膜镜检查、前段光学相干断层扫描(AS-OCT) (Carl Zeiss Meditec Inc.;都柏林,加州,美国)和Pentacam (Oculus Inc.;Lynnwood, WA, USA)。Pentacam扫描50张,计算前房容积12张。只有右眼被考虑进行分析。结果:纳入119名受试者的119只眼进行分析。受试者平均年龄42.58±13.15岁,其中女性74人,男性45人。AS-OCT测量的平均前房容积为119.17±26.56 mm3, Pentacam测量的平均前房容积为131.29±34.26 mm3。两种方式的均数比较具有统计学意义(t = -8.857, Mean Difference (MD) = 12.11, 95% CI: (4.29, 19.95), p = 0.003)。Bland-Altman图显示Pentacam和AS-OCT获得的腔室容积测量结果不一致,MD为12.1 mm3 (95% CI: 41.4至-17.1),两种仪器之间的类内相关性为0.94 (95% CI: 0.91, 0.96) (p < 0.0001)。结论:使用Pentacam和as - oct测量前房容积是可靠的。然而,由于一致性差,这些测量结果不能互换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of anterior chamber volume using Pentacam and anterior segment optical coherence tomography among normal subjects
Aim: To compare the anterior chamber volume measurements obtained with Pentacam and derived from anterior segment optical coherence tomography. Design: Cross-sectional study. Methods: We included normal subjects who underwent a comprehensive eye examination including refraction, keratometry, Goldmann applanation tonometry, gonioscopy, anterior segment optical coherence tomography (AS-OCT) (Carl Zeiss Meditec Inc.; Dublin, CA, USA) and Pentacam (Oculus Inc.; Lynnwood, WA, USA). Fifty scans were selected for Pentacam and 12 images were selected for calculation of anterior chamber volume. Only the right eye was considered for analysis. Results: One-hundred and nineteen eyes of 119 subjects were included for analysis. The mean age of the subjects was 42.58 ± 13.15 years, of which 74 were female and 45 were male. The mean anterior chamber volume measured using AS-OCT was 119.17 ± 26.56 mm3 and with Pentacam was 131.29 ± 34.26 mm3. The comparison of means between the two modalities was statistically significant (t = -8.857, Mean Difference (MD) = 12.11, 95% CI: (4.29, 19.95), p = 0.003). Bland-Altman plot showed poor agreement between the chamber volume measurements obtained by Pentacam and AS-OCT with MD of 12.1 mm3 (95 % CI: 41.4 to -17.1) and intra-class correlation between the two instruments was 0.94 (95% CI: 0.91, 0.96) (p < 0.0001). Conclusion: The anterior chamber volume can be measured using Pentacam as well as AS-OCT since these measurements were reliable. However, these measurements were not interchangeable due to poor levels of agreement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Asian Journal of Ophthalmology
Asian Journal of Ophthalmology Medicine-Ophthalmology
自引率
0.00%
发文量
0
期刊介绍: Asian Journal of OPHTHALMOLOGY is the official peer-reviewed journal of the South East Asia Glaucoma Interest Group (SEAGIG) and is indexed in EMBASE/Excerpta Medica. Asian Journal of OPHTHALMOLOGY is published quarterly (four [4] issues per year) by Scientific Communications International Limited. The journal is published on-line only and is distributed free of cost via the SEAGIG website.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信