{"title":"具有液滴喷射监测功能的3D打印气动分配器","authors":"Dong Kwan Kang,&nbsp;Jeong Woo Park,&nbsp;Sangmin Lee","doi":"10.1186/s40486-022-00157-4","DOIUrl":null,"url":null,"abstract":"<div><p>In this study, a pneumatic dispenser driven by a flexible membrane with a capacitive-type sensor using an SLA-type 3D printer was fabricated. It was confirmed that a single droplet in the range of approximately 400–450 nL could be ejected from the current processed 200-μm-diameter nozzle. The deformation varied according to the magnitude and time of the positive pressure applied to the membrane sensor. In addition, the signals of the normal dispensing and abnormal states, in which the solution was not ejected when the inlet pressure was removed, were measured and compared. The base capacitance-to-digital converter (CDC) value decreased when the inlet pressure was removed. Thus, it was able to confirm the feasibility of monitoring the normal and abnormal ejection status of the pneumatic dispenser.</p></div>","PeriodicalId":704,"journal":{"name":"Micro and Nano Systems Letters","volume":"10 1","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2022-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://mnsl-journal.springeropen.com/counter/pdf/10.1186/s40486-022-00157-4","citationCount":"0","resultStr":"{\"title\":\"A 3D-printed pneumatic dispenser with monitoring droplet ejection\",\"authors\":\"Dong Kwan Kang,&nbsp;Jeong Woo Park,&nbsp;Sangmin Lee\",\"doi\":\"10.1186/s40486-022-00157-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this study, a pneumatic dispenser driven by a flexible membrane with a capacitive-type sensor using an SLA-type 3D printer was fabricated. It was confirmed that a single droplet in the range of approximately 400–450 nL could be ejected from the current processed 200-μm-diameter nozzle. The deformation varied according to the magnitude and time of the positive pressure applied to the membrane sensor. In addition, the signals of the normal dispensing and abnormal states, in which the solution was not ejected when the inlet pressure was removed, were measured and compared. The base capacitance-to-digital converter (CDC) value decreased when the inlet pressure was removed. Thus, it was able to confirm the feasibility of monitoring the normal and abnormal ejection status of the pneumatic dispenser.</p></div>\",\"PeriodicalId\":704,\"journal\":{\"name\":\"Micro and Nano Systems Letters\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2022-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://mnsl-journal.springeropen.com/counter/pdf/10.1186/s40486-022-00157-4\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Micro and Nano Systems Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s40486-022-00157-4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"NANOSCIENCE & NANOTECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micro and Nano Systems Letters","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s40486-022-00157-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NANOSCIENCE & NANOTECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

在本研究中,利用sla型3D打印机制造了一种由柔性膜驱动的电容式传感器气动点胶器。结果表明,在当前加工的直径为200 μm的喷嘴中,可以喷射出400 ~ 450 nL的单液滴。变形根据施加在膜传感器上的正压力的大小和时间而变化。此外,测量并比较了正常点胶状态和移开入口压力时溶液不喷射的异常状态的信号。当进口压力降低时,基极电容-数字转换器(CDC)值降低。从而证实了对气动点胶机正常和异常弹射状态进行监测的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A 3D-printed pneumatic dispenser with monitoring droplet ejection

In this study, a pneumatic dispenser driven by a flexible membrane with a capacitive-type sensor using an SLA-type 3D printer was fabricated. It was confirmed that a single droplet in the range of approximately 400–450 nL could be ejected from the current processed 200-μm-diameter nozzle. The deformation varied according to the magnitude and time of the positive pressure applied to the membrane sensor. In addition, the signals of the normal dispensing and abnormal states, in which the solution was not ejected when the inlet pressure was removed, were measured and compared. The base capacitance-to-digital converter (CDC) value decreased when the inlet pressure was removed. Thus, it was able to confirm the feasibility of monitoring the normal and abnormal ejection status of the pneumatic dispenser.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Micro and Nano Systems Letters
Micro and Nano Systems Letters Engineering-Biomedical Engineering
CiteScore
10.60
自引率
5.60%
发文量
16
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信