控制- iq自动胰岛素输送对2型糖尿病患者基础注射和仅基础注射胰岛素的有益影响

Q2 Medicine
Clinical Diabetes Pub Date : 2024-01-01 Epub Date: 2023-08-28 DOI:10.2337/cd23-0025
Carol J Levy, Dan Raghinaru, Yogish C Kudva, Keta Pandit, Thomas Blevins, Luis Casaubon, Donna Desjardins, Camilla M Levister, Grenye O'Malley, Corey Reid, John Lum, Craig Kollman, Roy W Beck
{"title":"控制- iq自动胰岛素输送对2型糖尿病患者基础注射和仅基础注射胰岛素的有益影响","authors":"Carol J Levy, Dan Raghinaru, Yogish C Kudva, Keta Pandit, Thomas Blevins, Luis Casaubon, Donna Desjardins, Camilla M Levister, Grenye O'Malley, Corey Reid, John Lum, Craig Kollman, Roy W Beck","doi":"10.2337/cd23-0025","DOIUrl":null,"url":null,"abstract":"<p><p>The t:slim X2 insulin pump with Control-IQ technology (Control-IQ) advanced hybrid closed-loop automated insulin delivery system was evaluated in this prospective single-arm trial. Thirty adults with type 2 diabetes using the Control-IQ system showed substantial glycemic improvement with no increase in hypoglycemia. Mean time in range (70-180 mg/dL) improved 15%, representing an increase of 3.6 hours/day, and mean glucose decreased by 22 mg/dL.</p>","PeriodicalId":39894,"journal":{"name":"Clinical Diabetes","volume":" ","pages":"116-124"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10788662/pdf/","citationCount":"0","resultStr":"{\"title\":\"Beneficial Effects of Control-IQ Automated Insulin Delivery in Basal-Bolus and Basal-Only Insulin Users With Type 2 Diabetes.\",\"authors\":\"Carol J Levy, Dan Raghinaru, Yogish C Kudva, Keta Pandit, Thomas Blevins, Luis Casaubon, Donna Desjardins, Camilla M Levister, Grenye O'Malley, Corey Reid, John Lum, Craig Kollman, Roy W Beck\",\"doi\":\"10.2337/cd23-0025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The t:slim X2 insulin pump with Control-IQ technology (Control-IQ) advanced hybrid closed-loop automated insulin delivery system was evaluated in this prospective single-arm trial. Thirty adults with type 2 diabetes using the Control-IQ system showed substantial glycemic improvement with no increase in hypoglycemia. Mean time in range (70-180 mg/dL) improved 15%, representing an increase of 3.6 hours/day, and mean glucose decreased by 22 mg/dL.</p>\",\"PeriodicalId\":39894,\"journal\":{\"name\":\"Clinical Diabetes\",\"volume\":\" \",\"pages\":\"116-124\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10788662/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Diabetes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2337/cd23-0025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Diabetes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2337/cd23-0025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

在这项前瞻性单臂试验中,对采用Control IQ技术(Control IQ)的t:slim X2胰岛素泵进行了评估。使用Control IQ系统的30名患有2型糖尿病的成年人血糖显著改善,低血糖症没有增加。在范围(70–180 mg/dL)内的平均时间改善了15%,即每天增加3.6小时,平均葡萄糖减少了22 mg/dL。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Beneficial Effects of Control-IQ Automated Insulin Delivery in Basal-Bolus and Basal-Only Insulin Users With Type 2 Diabetes.

The t:slim X2 insulin pump with Control-IQ technology (Control-IQ) advanced hybrid closed-loop automated insulin delivery system was evaluated in this prospective single-arm trial. Thirty adults with type 2 diabetes using the Control-IQ system showed substantial glycemic improvement with no increase in hypoglycemia. Mean time in range (70-180 mg/dL) improved 15%, representing an increase of 3.6 hours/day, and mean glucose decreased by 22 mg/dL.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Diabetes
Clinical Diabetes Medicine-Internal Medicine
CiteScore
4.30
自引率
0.00%
发文量
93
期刊介绍: The mission of Clinical Diabetes is to provide primary care providers and all clinicians involved in the care of people with diabetes with information on advances and state-of-the-art care for people with diabetes. Clinical Diabetes is also a forum for discussing diabetes-related problems in practice, medical-legal issues, case studies, digests of recent research, and patient education materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信