影响IIIB期宫颈癌合并肾积水患者双“J”型支架置入预后的预测因素

G. N. K. Dinatha, Anak Agung Gde Oka, K. Santosa
{"title":"影响IIIB期宫颈癌合并肾积水患者双“J”型支架置入预后的预测因素","authors":"G. N. K. Dinatha, Anak Agung Gde Oka, K. Santosa","doi":"10.24843/jbn.2022.v06.i01.p01","DOIUrl":null,"url":null,"abstract":"Objective: To determine the predictive factors that influence the outcome of Double “J” (DJ) stent placement in stage IIIB cervical cancer patients with hydronephrosis complications. Methods: An analytical observational study with a historical cohort was performed. Patients included in this study was patient with stage IIIB cervical cancer with hydronephrosis complication at Sanglah hospital. We analyzed the influence of time range since diagnosis until DJ stent placement, degree of hydronephrosis, and glomerular filtration rate on the outcomes of DJ stent placement namely: Lower urinary tract symptoms (LUTS), quality of life (QoL), and glomerular filtration rate changes (GFR). Data were tabulated and statistically analyzed using SPSS 25. Results: Of the 44 samples, the mean age of the patients was 51,93 (±7.672) years. Late DJ stent placement increase the risk of severe LUTS (RR: 3.103; 95%CI: 1.319-7.301; p<0.001) compared to patients with early DJ stent placement. We also found that a low glomerular filtration rate (bad renal function) is significantly associated with worse quality of life (RR: 1.917; 95%CI: 1.296-2.835; p<0.001). Conclusion: Delayed DJ stent placement is associated with severe LUTS symptoms, and poor renal function resulted in a poor quality of life.","PeriodicalId":52988,"journal":{"name":"JBN Jurnal Bedah Nasional","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Predictive Factors Influencing the Outcomes of Double “J” Stent Placement in Stage IIIB Cervical Cancer Patients With Hydronephrosis Complication\",\"authors\":\"G. N. K. Dinatha, Anak Agung Gde Oka, K. Santosa\",\"doi\":\"10.24843/jbn.2022.v06.i01.p01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To determine the predictive factors that influence the outcome of Double “J” (DJ) stent placement in stage IIIB cervical cancer patients with hydronephrosis complications. Methods: An analytical observational study with a historical cohort was performed. Patients included in this study was patient with stage IIIB cervical cancer with hydronephrosis complication at Sanglah hospital. We analyzed the influence of time range since diagnosis until DJ stent placement, degree of hydronephrosis, and glomerular filtration rate on the outcomes of DJ stent placement namely: Lower urinary tract symptoms (LUTS), quality of life (QoL), and glomerular filtration rate changes (GFR). Data were tabulated and statistically analyzed using SPSS 25. Results: Of the 44 samples, the mean age of the patients was 51,93 (±7.672) years. Late DJ stent placement increase the risk of severe LUTS (RR: 3.103; 95%CI: 1.319-7.301; p<0.001) compared to patients with early DJ stent placement. We also found that a low glomerular filtration rate (bad renal function) is significantly associated with worse quality of life (RR: 1.917; 95%CI: 1.296-2.835; p<0.001). Conclusion: Delayed DJ stent placement is associated with severe LUTS symptoms, and poor renal function resulted in a poor quality of life.\",\"PeriodicalId\":52988,\"journal\":{\"name\":\"JBN Jurnal Bedah Nasional\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JBN Jurnal Bedah Nasional\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24843/jbn.2022.v06.i01.p01\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JBN Jurnal Bedah Nasional","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24843/jbn.2022.v06.i01.p01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨影响IIIB期宫颈癌合并肾积水患者行双J型(DJ)支架置入术预后的预测因素。方法:对历史队列进行分析性观察研究。本研究纳入的患者是Sanglah医院的IIIB期宫颈癌伴肾积水并发症患者。我们分析了从诊断到植入DJ支架的时间范围、肾积水程度和肾小球滤过率对DJ支架置入结果的影响,即:下尿路症状(LUTS)、生活质量(QoL)和肾小球滤过率变化(GFR)。采用SPSS 25对数据进行制表和统计分析。结果:44例患者的平均年龄为51,93(±7.672)岁。晚期DJ支架置入增加严重LUTS的风险(RR: 3.103;95%置信区间:1.319—-7.301;p<0.001)。我们还发现低肾小球滤过率(肾功能差)与较差的生活质量显著相关(RR: 1.917;95%置信区间:1.296—-2.835;p < 0.001)。结论:延迟放置DJ支架与严重的LUTS症状相关,肾功能差导致生活质量差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Predictive Factors Influencing the Outcomes of Double “J” Stent Placement in Stage IIIB Cervical Cancer Patients With Hydronephrosis Complication
Objective: To determine the predictive factors that influence the outcome of Double “J” (DJ) stent placement in stage IIIB cervical cancer patients with hydronephrosis complications. Methods: An analytical observational study with a historical cohort was performed. Patients included in this study was patient with stage IIIB cervical cancer with hydronephrosis complication at Sanglah hospital. We analyzed the influence of time range since diagnosis until DJ stent placement, degree of hydronephrosis, and glomerular filtration rate on the outcomes of DJ stent placement namely: Lower urinary tract symptoms (LUTS), quality of life (QoL), and glomerular filtration rate changes (GFR). Data were tabulated and statistically analyzed using SPSS 25. Results: Of the 44 samples, the mean age of the patients was 51,93 (±7.672) years. Late DJ stent placement increase the risk of severe LUTS (RR: 3.103; 95%CI: 1.319-7.301; p<0.001) compared to patients with early DJ stent placement. We also found that a low glomerular filtration rate (bad renal function) is significantly associated with worse quality of life (RR: 1.917; 95%CI: 1.296-2.835; p<0.001). Conclusion: Delayed DJ stent placement is associated with severe LUTS symptoms, and poor renal function resulted in a poor quality of life.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
12
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信