A. Sygulska, Tomasz Czerniak, Adrian Czarny-Kropiwnicki
{"title":"解决现代教堂声学问题的实验研究和计算机模拟","authors":"A. Sygulska, Tomasz Czerniak, Adrian Czarny-Kropiwnicki","doi":"10.3846/2029882X.2018.1445037","DOIUrl":null,"url":null,"abstract":"Architectural acoustics of contemporary sacred buildings is still an under-appreciated issue. Many contemporary churches are not functional enough due to acoustic defects which occur there. The study discusses issues of the modern Catholic church, where acoustic problems surface as high reverberant noise levels. The building under investigation, i.e. the Church of the Visitation of the Blessed Virgin Mary, is the biggest contemporary church in Poznan, Poland, as its internal volume amounts to 16,800 m³. On the basis of in situ investigations, a computer model of the church was built and a series of simulations were carried out to determine correct treatment in order to achieve satisfactory acoustic conditions. The main assumption was to find such a solution as not to affect the modernist architecture of the church.","PeriodicalId":11839,"journal":{"name":"Engineering Structures and Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental investigations and computer simulations to solve acoustic problems in the modern church\",\"authors\":\"A. Sygulska, Tomasz Czerniak, Adrian Czarny-Kropiwnicki\",\"doi\":\"10.3846/2029882X.2018.1445037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Architectural acoustics of contemporary sacred buildings is still an under-appreciated issue. Many contemporary churches are not functional enough due to acoustic defects which occur there. The study discusses issues of the modern Catholic church, where acoustic problems surface as high reverberant noise levels. The building under investigation, i.e. the Church of the Visitation of the Blessed Virgin Mary, is the biggest contemporary church in Poznan, Poland, as its internal volume amounts to 16,800 m³. On the basis of in situ investigations, a computer model of the church was built and a series of simulations were carried out to determine correct treatment in order to achieve satisfactory acoustic conditions. The main assumption was to find such a solution as not to affect the modernist architecture of the church.\",\"PeriodicalId\":11839,\"journal\":{\"name\":\"Engineering Structures and Technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-04-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering Structures and Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3846/2029882X.2018.1445037\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Structures and Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3846/2029882X.2018.1445037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental investigations and computer simulations to solve acoustic problems in the modern church
Architectural acoustics of contemporary sacred buildings is still an under-appreciated issue. Many contemporary churches are not functional enough due to acoustic defects which occur there. The study discusses issues of the modern Catholic church, where acoustic problems surface as high reverberant noise levels. The building under investigation, i.e. the Church of the Visitation of the Blessed Virgin Mary, is the biggest contemporary church in Poznan, Poland, as its internal volume amounts to 16,800 m³. On the basis of in situ investigations, a computer model of the church was built and a series of simulations were carried out to determine correct treatment in order to achieve satisfactory acoustic conditions. The main assumption was to find such a solution as not to affect the modernist architecture of the church.