{"title":"双纤尾塑料支架、鼻囊管和经皮导管联合应用于内镜超声引导下胰周液腔内引流","authors":"","doi":"10.33140/jpr.07.01.05","DOIUrl":null,"url":null,"abstract":"Background: Endoscopic ultrasound-guided drainage is first-line treatment of Pancreatic fluid collection. The invention of metallic stents has provided a safer and more efficient approach route for internal drainage. But because of the high cost of metal stents, a large number of patients still choose plastic stents, which can help them from the disease with much lower cost. Patients and Methods: Between March to December in 2017, 20 patients with Peripancreatic fluid collections were prospectively enrolled to receive the double pigtail plastic stent with nasocystic tube and/or percutaneous catheter. Results: There were 20 cases of pseudocyst including 4 cases of infected pseudocyst. The causes of the PFC were mainly gallstones (60%), followed with alcohol (30%) and hyperlipoidemia (10%). Technical success was achieved in 100% of the cases. All patients were completely resolved with the evidence of CT scan and clinical evaluation. The mean time for resolution was 15±20 days. The mean follow-up was 3 months. Conclusion: The combination drainage of double pigtail plastic stent with nasocystic tube and/or percutaneous catheter of pancreatic pseudocyst is feasible and efficacious to most patients. Using a titanium clip could prevent migration occurrence. With the economic benefits of plastic stents, they are still wildly used in developing countries.","PeriodicalId":16706,"journal":{"name":"Journal of Pharmaceutical Research","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Combination of Double Pigtail Plastic Stent, Nasocystic Tube and Percutaneous Catheter in Endoscopic Ultrasound-Guided Transluminal Drainage for Peripancreatic Fluid Collection\",\"authors\":\"\",\"doi\":\"10.33140/jpr.07.01.05\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Endoscopic ultrasound-guided drainage is first-line treatment of Pancreatic fluid collection. The invention of metallic stents has provided a safer and more efficient approach route for internal drainage. But because of the high cost of metal stents, a large number of patients still choose plastic stents, which can help them from the disease with much lower cost. Patients and Methods: Between March to December in 2017, 20 patients with Peripancreatic fluid collections were prospectively enrolled to receive the double pigtail plastic stent with nasocystic tube and/or percutaneous catheter. Results: There were 20 cases of pseudocyst including 4 cases of infected pseudocyst. The causes of the PFC were mainly gallstones (60%), followed with alcohol (30%) and hyperlipoidemia (10%). Technical success was achieved in 100% of the cases. All patients were completely resolved with the evidence of CT scan and clinical evaluation. The mean time for resolution was 15±20 days. The mean follow-up was 3 months. Conclusion: The combination drainage of double pigtail plastic stent with nasocystic tube and/or percutaneous catheter of pancreatic pseudocyst is feasible and efficacious to most patients. Using a titanium clip could prevent migration occurrence. With the economic benefits of plastic stents, they are still wildly used in developing countries.\",\"PeriodicalId\":16706,\"journal\":{\"name\":\"Journal of Pharmaceutical Research\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Pharmaceutical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.33140/jpr.07.01.05\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmaceutical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.33140/jpr.07.01.05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Combination of Double Pigtail Plastic Stent, Nasocystic Tube and Percutaneous Catheter in Endoscopic Ultrasound-Guided Transluminal Drainage for Peripancreatic Fluid Collection
Background: Endoscopic ultrasound-guided drainage is first-line treatment of Pancreatic fluid collection. The invention of metallic stents has provided a safer and more efficient approach route for internal drainage. But because of the high cost of metal stents, a large number of patients still choose plastic stents, which can help them from the disease with much lower cost. Patients and Methods: Between March to December in 2017, 20 patients with Peripancreatic fluid collections were prospectively enrolled to receive the double pigtail plastic stent with nasocystic tube and/or percutaneous catheter. Results: There were 20 cases of pseudocyst including 4 cases of infected pseudocyst. The causes of the PFC were mainly gallstones (60%), followed with alcohol (30%) and hyperlipoidemia (10%). Technical success was achieved in 100% of the cases. All patients were completely resolved with the evidence of CT scan and clinical evaluation. The mean time for resolution was 15±20 days. The mean follow-up was 3 months. Conclusion: The combination drainage of double pigtail plastic stent with nasocystic tube and/or percutaneous catheter of pancreatic pseudocyst is feasible and efficacious to most patients. Using a titanium clip could prevent migration occurrence. With the economic benefits of plastic stents, they are still wildly used in developing countries.