超声波仪器对终点线完整性的影响

S. I., Sharon E, Hendler A, B. G, Beytha N
{"title":"超声波仪器对终点线完整性的影响","authors":"S. I., Sharon E, Hendler A, B. G, Beytha N","doi":"10.26420/jdentapp.2021.1114","DOIUrl":null,"url":null,"abstract":"Purpose: Ultrasonic scaler is frequently used for temporary cement remnants removal from abutment teeth. A major concern is the alteration of the structural integrity of the abutment finishing line by the ultrasonic scaler. The current study evaluates the influence of ultrasonic scaling on the integrity of the finish line. The effect of finish line design (chamfer or feather edge), and its location (dentin or enamel) was also evaluated. Methods: Intact 22 human extracted molars were divided into 2 groups: finish line was prepared on enamel (n=11) and dentin (n=11), and further subdivided to finish line configuration groups (chamfer or knife-edge). Preparation of finish line was preformed following a standard repetitive procedure. 3D scans of the same tooth before and after ultrasonic instrumentation were performed. Pre and post scaling images were superimposed. The finish line alterations were evaluated and measured. The significance of the differences was evaluated using Students’ t-test. Results: The average alteration at the finish line area following ultrasonic scaling was 71.5 ± 24.6 μm. Higher alterations were found for enamel and for chamfer finish lines compared to dentin and knife edge, 134.4 ± 61.4 μm and 30.3 ±11.7 μm respectively. The highest change (228.6μm) was found for chamfer finish line located on enamel. The differences between groups were statistically significant (p<0.05). Conclusion: Ultrasonic scaling alters the topography of the finish line area of abutment teeth and thus may compromise marginal fit and integrity of the final restoration.","PeriodicalId":93776,"journal":{"name":"Journal of dental applications","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Ultrasonic Instrumentation on Finish Line Integrity\",\"authors\":\"S. I., Sharon E, Hendler A, B. G, Beytha N\",\"doi\":\"10.26420/jdentapp.2021.1114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: Ultrasonic scaler is frequently used for temporary cement remnants removal from abutment teeth. A major concern is the alteration of the structural integrity of the abutment finishing line by the ultrasonic scaler. The current study evaluates the influence of ultrasonic scaling on the integrity of the finish line. The effect of finish line design (chamfer or feather edge), and its location (dentin or enamel) was also evaluated. Methods: Intact 22 human extracted molars were divided into 2 groups: finish line was prepared on enamel (n=11) and dentin (n=11), and further subdivided to finish line configuration groups (chamfer or knife-edge). Preparation of finish line was preformed following a standard repetitive procedure. 3D scans of the same tooth before and after ultrasonic instrumentation were performed. Pre and post scaling images were superimposed. The finish line alterations were evaluated and measured. The significance of the differences was evaluated using Students’ t-test. Results: The average alteration at the finish line area following ultrasonic scaling was 71.5 ± 24.6 μm. Higher alterations were found for enamel and for chamfer finish lines compared to dentin and knife edge, 134.4 ± 61.4 μm and 30.3 ±11.7 μm respectively. The highest change (228.6μm) was found for chamfer finish line located on enamel. The differences between groups were statistically significant (p<0.05). Conclusion: Ultrasonic scaling alters the topography of the finish line area of abutment teeth and thus may compromise marginal fit and integrity of the final restoration.\",\"PeriodicalId\":93776,\"journal\":{\"name\":\"Journal of dental applications\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dental applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26420/jdentapp.2021.1114\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26420/jdentapp.2021.1114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:超声洁牙器常用于临时性去除基牙水泥残留。一个主要的问题是通过超声波定标器改变桥台修整线的结构完整性。目前的研究评估了超声波结垢对终点线完整性的影响。还评估了完成线设计(倒角或羽毛边缘)及其位置(牙本质或釉质)的效果。方法:将22颗完整的人磨牙分为2组:在釉质(n=11)和牙本质(n=11。完成线的准备工作按照标准的重复程序进行。在超声仪器前后对同一颗牙齿进行3D扫描。缩放前和缩放后的图像被叠加。对终点线的改动进行了评估和测量。差异的显著性采用Students t检验进行评估。结果:超声洁治后终点区域的平均变化为71.5±24.6μm。与牙本质和刀刃相比,牙釉质和倒角完成线的变化更大,分别为134.4±61.4μm和30.3±11.7μm。搪瓷上的倒角完成线变化最大(228.6μm)。结论:超声洁牙术改变了基牙完成线区域的形貌,从而可能损害最终修复体的边缘拟合和完整性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Ultrasonic Instrumentation on Finish Line Integrity
Purpose: Ultrasonic scaler is frequently used for temporary cement remnants removal from abutment teeth. A major concern is the alteration of the structural integrity of the abutment finishing line by the ultrasonic scaler. The current study evaluates the influence of ultrasonic scaling on the integrity of the finish line. The effect of finish line design (chamfer or feather edge), and its location (dentin or enamel) was also evaluated. Methods: Intact 22 human extracted molars were divided into 2 groups: finish line was prepared on enamel (n=11) and dentin (n=11), and further subdivided to finish line configuration groups (chamfer or knife-edge). Preparation of finish line was preformed following a standard repetitive procedure. 3D scans of the same tooth before and after ultrasonic instrumentation were performed. Pre and post scaling images were superimposed. The finish line alterations were evaluated and measured. The significance of the differences was evaluated using Students’ t-test. Results: The average alteration at the finish line area following ultrasonic scaling was 71.5 ± 24.6 μm. Higher alterations were found for enamel and for chamfer finish lines compared to dentin and knife edge, 134.4 ± 61.4 μm and 30.3 ±11.7 μm respectively. The highest change (228.6μm) was found for chamfer finish line located on enamel. The differences between groups were statistically significant (p<0.05). Conclusion: Ultrasonic scaling alters the topography of the finish line area of abutment teeth and thus may compromise marginal fit and integrity of the final restoration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信