H. Mayrovitz, C. Lorenzo-Valido, E. Pieper, A. Thomas
{"title":"前臂和二头肌皮肤组织介电常数和紧实度的周向变化。","authors":"H. Mayrovitz, C. Lorenzo-Valido, E. Pieper, A. Thomas","doi":"10.2458/lymph.4672","DOIUrl":null,"url":null,"abstract":"Tissue dielectric constant (TDC) and skin firmness assessed via indentation force (FORCE) help quantify lymphedema and track changes. We sought to determine potential differences in these parameters dependent on arm circumferential locations. Thus, TDC and FORCE were measured in 40 healthy women at medial, anterior and lateral locations on forearm and biceps. In five other women with unilateral lymphedema (68.6±7.6 years), TDC was measured at corresponding circumferential forearm positions. Measurements were done in triplicate using compact noninvasive devices. Results for healthy women (23.8±2.7 years) showed forearm medial TDC values (26.7±2.2) were less than anterior (28.0±2.4) or lateral (28.0±2.5) positions (p<0.001). Lymphedema patients had elevated values but similar medialanterior- lateral patterns (33.7±8.0, 39.8±10.2 and 42.9±10.0). Biceps medial TDC values (24.1±2.2) were also less than either anterior (27.0±2.1) or lateral (28.2±3.3). Contrastingly, medial FORCE values at forearm and biceps were less than at anterior and lateral locations (p<0.001) and increased in the order of medialanterior- lateral on forearm (p<0.001). The present findings provide reference values for both TDC and FORCE of commonly measured arm sites with specificity as to circumferential variations. This observed variation indicates the need for care in locating measurement positions for tracking patients with lymphedema.","PeriodicalId":51122,"journal":{"name":"Lymphology","volume":"53 4 1","pages":"204-211"},"PeriodicalIF":0.7000,"publicationDate":"2021-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Forearm and biceps circumferential variations in skin tissue dielectric constant and firmness.\",\"authors\":\"H. Mayrovitz, C. Lorenzo-Valido, E. Pieper, A. Thomas\",\"doi\":\"10.2458/lymph.4672\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Tissue dielectric constant (TDC) and skin firmness assessed via indentation force (FORCE) help quantify lymphedema and track changes. We sought to determine potential differences in these parameters dependent on arm circumferential locations. Thus, TDC and FORCE were measured in 40 healthy women at medial, anterior and lateral locations on forearm and biceps. In five other women with unilateral lymphedema (68.6±7.6 years), TDC was measured at corresponding circumferential forearm positions. Measurements were done in triplicate using compact noninvasive devices. Results for healthy women (23.8±2.7 years) showed forearm medial TDC values (26.7±2.2) were less than anterior (28.0±2.4) or lateral (28.0±2.5) positions (p<0.001). Lymphedema patients had elevated values but similar medialanterior- lateral patterns (33.7±8.0, 39.8±10.2 and 42.9±10.0). Biceps medial TDC values (24.1±2.2) were also less than either anterior (27.0±2.1) or lateral (28.2±3.3). Contrastingly, medial FORCE values at forearm and biceps were less than at anterior and lateral locations (p<0.001) and increased in the order of medialanterior- lateral on forearm (p<0.001). The present findings provide reference values for both TDC and FORCE of commonly measured arm sites with specificity as to circumferential variations. This observed variation indicates the need for care in locating measurement positions for tracking patients with lymphedema.\",\"PeriodicalId\":51122,\"journal\":{\"name\":\"Lymphology\",\"volume\":\"53 4 1\",\"pages\":\"204-211\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lymphology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2458/lymph.4672\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lymphology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2458/lymph.4672","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

通过压痕力(force)评估的组织介电常数(TDC)和皮肤硬度有助于量化淋巴水肿并跟踪变化。我们试图确定这些参数中取决于手臂圆周位置的潜在差异。因此,对40名健康女性前臂和二头肌内侧、前侧和外侧的TDC和FORCE进行了测量。在其他5名患有单侧淋巴水肿的女性(68.6±7.6岁)中,测量了前臂相应圆周位置的TDC。使用小型非侵入性装置进行一式三份的测量。健康女性(23.8±2.7岁)的结果显示,前臂内侧TDC值(26.7±2.2)小于前(28.0±2.4)或外侧(28.0士2.5)位置(p<0.001)。淋巴水肿患者的值升高,但内侧-外侧模式相似(33.7±8.0、39.8±10.2和42.9±10.0)。肱二头肌内侧TDC值也小于前(27.0±2.1)或外侧(28.2±3.3)。相比之下,前臂和二头肌的内侧FORCE值小于前侧和外侧(p<0.001),并按前臂内侧-外侧的顺序增加(p<001)。本研究结果为常用测量的手臂部位的TDC和FORCE提供了参考值,并对周向变化具有特异性。这种观察到的变化表明,在追踪淋巴水肿患者的测量位置时需要小心。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Forearm and biceps circumferential variations in skin tissue dielectric constant and firmness.
Tissue dielectric constant (TDC) and skin firmness assessed via indentation force (FORCE) help quantify lymphedema and track changes. We sought to determine potential differences in these parameters dependent on arm circumferential locations. Thus, TDC and FORCE were measured in 40 healthy women at medial, anterior and lateral locations on forearm and biceps. In five other women with unilateral lymphedema (68.6±7.6 years), TDC was measured at corresponding circumferential forearm positions. Measurements were done in triplicate using compact noninvasive devices. Results for healthy women (23.8±2.7 years) showed forearm medial TDC values (26.7±2.2) were less than anterior (28.0±2.4) or lateral (28.0±2.5) positions (p<0.001). Lymphedema patients had elevated values but similar medialanterior- lateral patterns (33.7±8.0, 39.8±10.2 and 42.9±10.0). Biceps medial TDC values (24.1±2.2) were also less than either anterior (27.0±2.1) or lateral (28.2±3.3). Contrastingly, medial FORCE values at forearm and biceps were less than at anterior and lateral locations (p<0.001) and increased in the order of medialanterior- lateral on forearm (p<0.001). The present findings provide reference values for both TDC and FORCE of commonly measured arm sites with specificity as to circumferential variations. This observed variation indicates the need for care in locating measurement positions for tracking patients with lymphedema.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lymphology
Lymphology 医学-免疫学
CiteScore
5.20
自引率
8.00%
发文量
29
审稿时长
3 months
期刊介绍: The Journal contains original articles, special features (see below), and information regarding the International Society of Lymphology. It seeks original papers dealing with clinical and basic studies of the lymphatic system and its disorders including related fields. Articles are accepted for external review and publication on the condition that they are contributed to Lymphology only and that no substantial part has been or will be published elsewhere.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信